transilluminators uv crosslinkers imaging systems photo documentation workstations uv lamps digital radiometers uv protective eye and face wear

[close]

p. 2

about spectronics corporation spectronics corporation is the world s leading manufacturer of high-quality ultraviolet products for the life science and laboratory fields for today s researcher spectronics offers a wide range of products that includes uv lamps transilluminators crosslinkers imaging systems viewing cabinets and photo-documentation workstations these state-of-the-art products are built to exacting standards and are used for applications that demand uncompromising quality and reliability most of our models are ul listed csa approved and ce approved spectronics modern 100,000 square foot manufacturing facility and office headquarters is located in westbury new york nearly 200 personnel are involved in all phases of research and development manufacturing sales marketing customer service and logistical and technical support more than five decades after its inception the goal of spectronics is still the same to produce effective top-quality products with the utmost dedication to customer satisfaction.

[close]

p. 3

table of contents page transilluminators 4-8 ultraviolet standard series 6 slimlinetm series 6 selecttm series 7 uv/visible combination · bi-o-visiontm series 7 accessories for transilluminators 8 · · · uv crosslinkers 9-11 spectrolinkertm series 10 selecttm series 10 genelinetm imaging systems 12-18 component style · imageezetm series 13 · digicamtm series 13 · epi-digicamtm series 14 imagesourcetm image acquisition software 15 imageaidetm image analysis software 16 genelinetm components and accessories 18 fluorescence analysis workstations 19-22 portable viewing cabinets cm-series 19 fluorescence analysis cabinets cx-series 20 large viewing and photographic cabinets cc and cl-series 21 accessories for photo documentation workstations 21 ultraviolet lamps 23-26 hand-held uv lamps e-series 23 uv bench and display lamps x-series 25 digital radiometers/photometers 27-32 microprocessor-controlled meters accumaxtm series 28 single-wavelength dm-series 30 multi-wavelength drc-series 30 multi-wavelength dse-series 31 uv/visible radiometer kits 32 accessories for digital radiometers 32 uv protective eye and face wear 33 warranty information 34 customer service/technical assistance 34 product index 35

[close]

p. 4

transilluminators product lines standard series · 15-watt models provide higher uv intensities · models are available in various uv wavelengths filter sizes timer options and uv-blocking covers slimlinetm series · 8-watt models ideal for small 11x14cm samples · available in various uv wavelengths and equipped with uv-blocking cover background used for the visualization of molecular samples transilluminators have become indispensable tools in today s life science laboratories they are also ideal for use in forensic science fluorescence detection and much more given their valuable role it is important for researchers to consider factors such as proper wavelength light intensity wattage and uniformity as well as convenience when choosing the right uv or visible transilluminator for optimum results and value based on their typical applications when it comes to uv emission great concerns are often paid to the unit s fluorescent response and protection against uv-induced dna damage spectroline® uv transilluminators offering the world s largest selection address these important issues and concerns selecttm series · 8-watt single wavelength mw models provide cost effective 312nm uv sources · 8-watt lw mw and sw combination units offer multiple wavelength convenience in one transilluminator · available in various filter sizes and equipped with uv-blocking cover bi-o-visiontm series · 8-watt uv and white light tubes provide dual light sources in one transilluminator · available with and without variable intensity control and equipped with uv-blocking cover application the wavelength requirement for a unit will depend on the type of fluorophore molecule and the amount of nucleic acid present in the gel for some of the newer fluorescent dyes such as sybr® sypro® and gelstar® series use of wavelengths longer than uv blue and longer visible spectrums are better suited for viewing and documentation for more common uv applications ethidium bromide gels are well illuminated with medium wavelength 312nm or mw transilluminators while units with shorter wavelength 254nm or sw may be used for better signal to background contrast it must be noted that with long-term exposure they may cause photonicking photodimerization and photobleaching when working with a small amount of nucleic acid material longer wavelength models 365nm or lw are better suited for extended sampling by minimizing these uv-induced damages high power 15-watt units offering increased uv intensities are best suited when working with a small amount of nucleic acid since they enhance illumination of faint bands these units provide the high uv irradiance needed to excite fluorophore molecules in electrophoresis gels and thin layer chromatograms although there are even higher-powered models on the market 25-watt the excessive uv intensity emitted will increase the unnecessary risk of sample photobleaching not to mention higher unit cost standard 8-watt units are ideal for quick viewing of normal amounts of dna typical enzyme restriction digest models with variable-intensity controls offer intensity adjustments for viewing and image acquisition according to the amount of material present as well as the fluorophores used.

[close]

p. 5

transilluminators ultraviolet known for their exceptional performance and durability spectroline® transilluminators are designed to deliver optimal uv intensity and extremely uniform uv emission to guarantee clear and reproducible results spectroline transilluminators provide maximum fluorescent response for nanogram sensitivity with minimal uv damage to samples with a variety of choices in wavelength wattage filter size and variable intensity controls each unit offers high intensity uniform uv emission and cool operation they feature a wide variety of uv filter glass sizes to accommodate different sizes of gels and blots as well as rugged construction and simple operation when working with uv models attention should be given to the age of the uv tubes as this will affect the sample fluorescent signals as the uv tubes age in any transilluminator their output steadily declines making faint bands more difficult to see this can result in lack of positive results and incorrect densitometric measurements regular replacement of uv tubes is suggested particularly for transilluminators that are shared or heavily used features · longlifetm uv filter glass inhibits solarization up to 50 times longer than traditional uv filters · easy-to-clean rugged housing composed of durable stainless-steel filter frame welded to scratch-resistant painted metal · powerful cooling fan maintains low filter glass temperature to eliminate surface heat buildup · minimal uv damage 312nm and 365nm models virtually eliminate transmission of 254nm radiation features diffusing screen all 312nm and 365nm models come with a unique removable polymer-based diffusing screen that ensures uniform uv emission and excellent irradiance uniformity at the sample surface it also improves the quality of photographic images · special diffusing screen d ensures superior surface uniformity by eliminating striations caused by the contours of the tubes provided on all 312nm and 365nm models · variable-intensity control v provides continuous intensity adjustments from 100 down to 20 for maximum sample preparation time and sensitivity · on/off switch s controls power to the unit · automatic shut-off timer t prevents uv overexposure doubles as on/off switch photos taken with left and without right spectroline diffusing screen · hinged uv-blocking cover c adjustable to a comfortable angle providing the end user with a clear view of surface access for sample manipulation eliminates the need for additional uv-absorbing clothing or face wear and protects the filter surface from accidental damage longlifetm filter glass found on all 254nm and certain 312nm models 2f-assembly series this special filter glass inhibits solarization up to 50 times longer than traditional uv filters 100 80 60 40 20 0 0 250 500 750 1,000 1,250 1,500 1,750 2,000 2,250 2,500 life test of longlife filter using medium wave uv screen exposure at 11,000 µw/cm2 intensity level transilluminators

[close]

p. 6

transilluminators standard series single wavelength uv · · · · · · 15-watt units provide high uv intensity fixed-intensity models include ts tc tr and tl-series variable-intensity models with uv-blocking cover include tv-series models accommodate a variety of sample sizes housing dimensions w xlxh 18.5 x 19.25 x 4 34.3 x 48.9 x 10.2cm available in 120v/60hz 230v/50hz 240v/50hz and 100v/50-60hz fixed-intensity ts tc tr and tl-series model ts-254r ts-312r ts-365r tc-254r tc-312r tc-365r tr-254r tr-312r tr-365r tl-254r tl-312r tl-365r wavelength 254nm 312nm 365nm 254nm 312nm 365nm 254nm 312nm 365nm 254nm 312nm 365nm filter size 6 x 6 15 x 15cm 6 x 6 15 x 15cm 6 x 6 15 x 15cm 8 x 8 20 x 20cm 8 x 8 20 x 20cm 8 x 8 20 x 20cm 6 x 14 15 x 35cm 6 x 14 15 x 35cm 9 x 13 23 x 33cm 8 x 16 20 x 40cm 8 x 16 20 x 40cm 8 x 16 20 x 40cm filter assembly 2f606b 3f606r 2f326b 2f808b 3f808r 2f883b 2f614b 2f614b 2f365b 2f816b 2f816b 2f168b tubes 6 15w sw ble-1t155 6 15w mw ble-1t158 6 15w lw ble-1t151 6 15w sw ble-1t155 6 15w mw ble-1t158 6 15w lw ble-1t151 6 15w sw ble-1t155 6 15w mw ble-1t158 6 15w lw ble-1t151 6 15w sw ble-1t155 6 15w mw ble-1t158 6 15w lw ble-1t151 features s s d s d t t d t d s s d s d t t d t d variable-intensity tv-series model tvc-312r tvr-312r tvl-312r wavelength 312nm 312nm 312nm filter size 8 x 8 20 x 20cm 6 x 14 15 x 35cm 8 x 16 20 x 40cm filter assembly 3f808r 2f614b 2f816b tubes 6 15w mw ble-1t158 6 15w mw ble-1t158 6 15w mw ble-1t158 features s d c v s d c v s d c v slimlinetm series single wavelength uv · · · · · small footprint 8-watt units provide standard uv intensity fixed-intensity models include te-series in various wavelengths ideal for mini gels housing dimensions w xlxh 11.5 x 14 x 2.5 29.2 x 35.6 x 5.7cm available in 120v/60hz 230v/50hz 240v/50hz and 100v/50-60hz this popular space-saving model delivers superior performance comparable to our standard models the unit s small footprint requires minimal bench space it features a filter glass that measures 4.3 x 5.5 11 x 14 cm ideal for working with mini gels model te-254s te-312s te-365s wavelength 254nm 312nm 365nm filter size 4 x 5 11 x 14cm 4 x 5 11 x 14cm 4 x 5 11 x 14cm filter assembly 2f405 3f405s 2f685 tubes 4 8w sw ble-8t254 4 8w mw ble-8t312 4 8w lw ble-8t365 features s c s d c s d c

[close]

p. 7

transilluminators selecttm series single/dual-wavelength uv · · · · · economical 8-watt units provide standard uv intensity fixed-intensity 312nm models accommodate a variety of sample sizes dual-wavelength models include td-series housing dimensions w xlxh 12 x 13.25 x 3.5 30.5 x 33.7 x 8.9cm available in 120v/60hz 230v/50hz 240v/50hz and 100v/50-60hz select series transilluminators offer all the features and benefits of our standard fixed-intensity series but designed with a cost-effective housing dual wavelengths in combinations of 365/312nm 312/254nm and 365/254nm provide broader uv applications single and dual-wavelength models accommodate a variety of sample gel or blot sizes with rugged construction and simple operation all select series units feature hinged uv-blocking cover to protect the user from radiation and uv filter glass to inhibit solarization single wavelength model ts-312e tc-312e ti-312e wavelength 312nm 312nm 312nm filter size 6 x 6 15 x 15cm 8 x 8 20 x 20cm 8 x 10 21 x 26cm filter assembly 3f606e 3f808e 3f810e tubes 6 8w mw ble-8t312 6 8w mw ble-8t312 6 8w mw ble-8t312 features s d c s d c s d c dual-wavelength td-series model td-2000e td-2010e td-2020e td-2100e td-2110e td-2120e wavelengths 365/312nm 312/254nm 365/254nm 365/312nm 312/254nm 365/254nm filter size 8 x 8 20 x 20cm 8 x 8 20 x 20cm 8 x 8 20 x 20cm 8 x 10 21 x 26cm 8 x 10 21 x 26cm 8 x 10 21 x 26cm filter assembly 3f808f 2f808e 2f808e 3f810e 2f810e 2f810e tubes 5 8w lw ble-8t365 5 8w mw ble-8t312 5 8w mw ble-8t312 5 8w sw ble-8t254 5 8w lw ble-8t365 5 8w sw ble-8t254 5 8w lw ble-8t365 5 8w mw ble-8t312 5 8w mw ble-8t312 5 8w sw ble-8t254 5 8w lw ble-8t365 features s d c s d c s d c s d c s d c s d c uv/visible combination transilluminators bi-o-visiontm series uv/white light · · · · · 8-watt units provide standard uv intensity side-by-side uv/white filter sections available in fixed and variable intensity models housing dimensions w xlxh 18.5 x 19.25 x 4 34.3 x 48.9 x 10.2cm available in 120v/60hz 230v/50hz 240v/50hz and 100v/50-60hz bi-o-vision uv/white light transilluminators offer both medium wave uv 312nm and white light for dual-light convenience in one box each side of the sample platform fits samples up to 8 x 8 20.3 x 20.3 cm for added safety only uv or white light can be selected with single uv/off/vis toggle switch the td-1000r model offers fixed-intensity while the tvd-1000r offers variable-intensity control of either uv or white light these units are continuously adjustable from 100 down to 50 model td-1000r tvd-1000r wavelengths 312nm/white 312nm/white filter size 8 x 8 20 x 20cm 8 x 8 20 x 20cm filter assembly 3f959r 3f959r tubes 5 8w mw ble-8t312 3 8w white ble-1t230 5 8w mw ble-8t312 3 8w white ble-1t230 features s d c s d c v transilluminators

[close]

p. 8

transilluminators accessories for uv transilluminators hinged uv-blocking cover · fits over gels blots and tlc plates · protects users from uv exposure · extremely durable transparent hinged cover shields the user from hazardous uv radiation and protects the filter from damage caused by dropping objects on the glass cover fits over all gels and tlc plates and can be easily attached to hinges on either side of the unit constructed of heavy-duty acrylic-based uv-blocking material uv-transmitting filter protector · allows manipulation of gels · prevents damage to the filter · resistant to solarization manipulate gels directly on the transilluminator uv-transmitting filter protector shields the costly filter glass from cuts scratches breakage etc transparent thermoplastic protectors are super-resistant to solarization and last longer than traditional uv protectors each protector covers the transilluminator platform completely attached rubber bumpers keep protector in place and minimizes heat build-up at transilluminator surface model uvc-100a cover uvc-250a cover uvt-75a filter protector uvt-150a filter protector size w xlxh 10.75 x 12.0 x 1.0 27.3 x 30.5 x 2.5cm 18.0 x 13.0 x 1.0 45.7 x 33.0 x 2.5cm 13.75 x 10.0 0.4 34.9 x 25.4 x 1.0cm 19.2 x 12.2 0.4 48.8 x 31 x 1.0cm fits slimline and select series tc td tl tr ts and tv-series slimline and select series tc td tl tr ts and tv-series

[close]

p. 9

uv crosslinkers product lines spectrolinkertm series · rugged anodized aluminum housing · long lasting anodized aluminum chamber prevents rusting · available in sw mw and lw wavelengths · interior chambers available in two sizes selecttm series · cost-effective painted metal housing background one of the persistent problems facing researchers working with nucleic acids is that the genetic materials can be damaged by the very processes used to study them for example to achieve high sensitivity with low background signals during nucleic acid hybridization or reprobing high concentrations of salts such as sodium dodecyl sulfate sds or detergents are added to the hybridization buffers and washes this often leads to loss of nucleic acid from blotted hybridization membranes resulting in lowered or no positive signals strengthening the bonds of the genetic material to the membrane offers the ideal solution to this problem covalent binding can be achieved by uv crosslinking or by prolonged vacuum baking of the membranes which often causes heat damage to the samples the crosslinking process utilizes short wave 254nm uv light to covalently bond nucleic acids to either nitrocellulose or nylon membranes a process whereby thymine dimers are formed between the nucleic acids and the membrane uv crosslinking is a quick easy and effective procedure to avoid the loss of nucleic acids during the hybridization process leading to increased sensitivity and enhanced signals the spectrolinkertm was developed to be one of the most advanced versatile and accurate uv crosslinkers with the success of spectrolinker came the selecttm series uv crosslinkers created specifically for the needs of researchers with limited budget designed to monitor uv radiation and self-adjust to variations in uv intensity all spectroline uv crosslinkers feature a smart microprocessor controller and unique true uv monitoring circuitry to enable users to get errorfree results with speed accuracy and safety these units are built specifically to eliminate time-consuming adjustments unnecessary repetitive programming and unwarranted risk of sample damage · long-lasting anodized aluminum chamber prevents rusting · available in sw mw and lw wavelengths features · covalently binds nucleic acid sequences and hybridization membranes in 30 seconds or less · safeguards your valuable test results from washouts · ensures optimum nucleic acid membrane binding even when uv output varies · provides ultimate ease of use and accuracy with smart microprocessor controller · protects users from uv exposure with fully enclosed chamber uv crosslinkers

[close]

p. 10

uv crosslinkers applications uv crosslinking of dna and rna after northern southern slot or dot blots and colony or plaque lifts pcr decontamination nicking ethidium bromide-stained dna in agarose gels gene mapping for cleavage-inhibiting thymine dimers reca mutation screening in e.coli uv sterilization continuous uv dosing miscellaneous uv-dosage applications including uv-induced polymerization or drying spectrolinkertm series selecttm series the 254nm versions of the spectrolinker and select series uv crosslinkers provide super-fast dna and rna crosslinking to membranes for improved hybridization-signal sensitivity at peak these units can process samples in under 30 seconds that s 240 times faster than vacuum-oven baking our exclusive wavelength-specific multi-stack uv photo sensor which is factory-calibrated to nist standards provides precise uv-only dosage measurements full range display resolution is accurate to 5µw/cm2 emi/rfi protection all models from both series offer exceptional accuracy and precision irradiation even compensating for aging uv tubes when output diminishes over time programmable smart microprocessor controller · · · · led-function indicators and color-coded keypad built-in help messages four operation modes auto repeat function remembers last operation without reprogramming four operation modes · optimal crosslink mode automatically provides a preset uv energy dosage of 120 mj/cm2 · energy-set mode 0-999,990 µj/cm2 allows for variable amounts of uv energy to be programmed · time mode 0-9,900 seconds allows for variable time settings to be established · intensity mode shows steady-state uv intensity output note all units have an irradiance display resolution of ±5µw/cm2 over the entire range 10

[close]

p. 11

uv crosslinkers built-in help messages · · · · · bulb when the uv tubes need to be replaced door open the unit also protects users from accidental uv radiation when the door is opened during a run end end of cycle confirmed with display and audible beep remaining time/energy provides operation status report when the operation has been interrupted the reset button cancels the latest settings and start button automatically resumes the current operation standard size spectrolinkertm xl-1000 series and selecttm xle-series · · · · · · overall housing dimensions w xhxd 19.5 x 10.5 x 9 49.5 x 26.7 x 22.9cm effective inner chamber dimensions w xhxd 13.5 x 7.0 x 7.5 34.3 x 17.8 x 19.1cm door dimensions w x h 12.0 x 6.25 30.5 x 15.9cm viewing window dimensions w x h 6.0 x 2.5 15.2 x 6.4cm for xl-series 6.0 x 3.0 15.2 x 7.6cm for xle-series net weight 17.5 lb 7.9kg power 120v-60hz-2a 230v-50hz-2a 100v-50/60hz-2a model xl-1000 xle-1000 xl-1000a xle-1000a xl-1000b xle-1000b wavelength 254nm 365nm 312nm tubes 5 8w sw ble-8t254 5 8w lw ble-8t365 5 8w mw ble-8t312 large size spectrolinkertm xl-1500 series · · · · · · overall housing dimensions w xhxd 24.0 x 10.5 x 14 61.0 x 26.7 x 35.6cm effective inner chamber dimensions w xhxd 18.25 x 6.25 x 12.5 46.4 x 15.9 x 31.8cm door dimensions w x h 16.0 x 6.25 40.6 x 15.9cm viewing window dimensions w x h 6.0 x 2.5 15.2 x 6.4cm net weight 26 lb 11.8kg power 120v-60hz-3a 230v-50hz-3a 100v-50/60hz-3a wavelength 254nm 365nm 312nm model xl-1500 xl-1500a xl-1500b tubes 6 15w sw ble-1t155 6 15w lw ble-1t151 6 15w mw ble-1t158 11 uv crosslinkers transilluminators

[close]

p. 12

genelinetm imaging systems product lines imageezetm · advanced ccd camera with enhanced pixel resolution · compact darkroom hood · computer interface card · imagesourcetm acquisition software · imageaidetm analysis software · with or without transilluminator digicamtm · digital color camera with auto zoom · compact darkroom hood · compatible with user-supplied pc desktop or laptop and stand-alone transilluminators · digital camera software offers direct link to imageaide analysis software with twain acquisition feature components background genelinetm imaging systems allow the end user to acquire view transfer archive and analyze gel images all in real time and in a digitized pc format choose complete fully automated systems imageezetm and digicamtm series or combine separate components for your individual application needs our geneline products combine cameras and image acquisition software to provide consistently high quality gel images the acquisition software acquires images provides further manipulation and saves the images all with computer-control for ultimate ease at the touch of a button the imageaidetm analysis software receives digitized image directly by activating one button or can alternatively import any picture-formatted document bmp jpg and tif extensions the software performs a complete autoanalysis and quantification of the images including band matching instantly · digital or ccd camera kits with applicable lenses and filters · darkroom hood or cabinets for transillumination or epi-illumination needs · imagesource acquisition kit with pci card software and camera cables · imageaide analysis kit with band matching software and security key 1

[close]

p. 13

genelinetm imaging systems component style imageeze tm series · · · · · · features laboratory grade 8-bit ccd camera components provide easy connection to user-supplied pc ultimate simplicity in image acquisition analysis and reporting one button transfer of acquired image to analysis software gels blots and colony images are easily acquired and analyzed complete package available with uv transilluminator gl-3001 gl-3051 imageeze is a complete image acquisition and analysis gel documentation system components include a ccd camera with enhanced pixel resolution mounted onto a darkroom hood a computer interface pci card imagesourcetm image acquisition software and imageaidetm analysis software imagesource software provides for control of real time images with automatic exposure control then transfers image data to imageaide for sophisticated icon-driven analyses of all types of images imageeze specifications camera lens filter assembly images camera hood with ccd camera bracket acquisition software analysis software band matching 8-bit ccd with on-chip integration 8-48mm zoom +2 diopter lens and standard uv/ir filter 768 x 494 pixels fits over 21 x 26cm 8 x 10 samples imagesource for automated image capture imageaide for gels colonies spots blots manual band quantification model gl-3001 gl-3051 product imageeze band matching system imageeze band matching plus camera kit/hood gl-4500a/gl-1000 gl-4500a/gl-1000 acquisition gl-3100 gl-3100 analysis gl-3300 gl-3300 transilluminator optional tvc-312r digicamtm series gl-4001b digicam is designed to provide the ultimate flexibility in acquiring viewing transferring archiving and analyzing gel images all in a completely digital format usb camera to pc connection provides ultimate simplicity over traditional ccd camera systems by eliminating the need for installation of computer interface card acquisition board for image manipulation digicam offers direct loading twain acquisition of saved images to imageaide for further image analyses and band quantification gl-4051b 1 geneline imaging systems · high-resolution digital color camera · complete acquisition software compatible with user-supplied pc laptop or desktop · digital camera software offers direct link to imageaide analysis software with twain acquisition for ultimate glp compliance · complete package available with uv transilluminator

[close]

p. 14

genelinetm imaging systems digicamtm specifications camera lens filter assembly images camera hood with digital camera bracket interface acquisition software with digital camera analysis software band matching digital camera auto zoom digital zoom and standard uv/ir filter 7.1 megapixels or greater fits over 21 x 26cm 8 x 10 samples usb a/v output ntsc or pal solution disk for automated image capturing imageaide for gels colonies spots blots manual band quantification model gl-4001b gl-4051b product digicam band matching system digicam band matching plus camera kit/hood gl-4200b/gl-1001 gl-4200b/gl-1001 acquisition solution disk solution disk analysis gl-3300 gl-3300 transilluminator optional tvc-312r epi-digicamtm series · features digicam system with additional dual uv/white light epi-illumination sources · includes fluorescence analysis cabinet with white light outfitted with uv lamp 312nm/254nm for epi-illumination · add spectroline uv/white light transilluminator for transillumination · complete package available with uv transilluminator for those requiring sample illumination from above and below our cost-effective epi-digicamtm is a digital acquisition and analysis system in a single darkroom cabinet-style for epi-illumination of samples the cc-80 fluorescence analysis cabinet see fluorescence analysis workstations section for details is equipped with ebf-280c our most versatile 8-watt short and medium wavelength uv lamp see section on hand-held uv lamps for details for brighter fluorescent response cc-80 can accommodate additional spectroline e-series uv lamps varying in uv short medium and long wavelength combinations for uv/white light transillumination add an optional bi-o-vision transilluminator see section on transilluminators for details epi-digicam specifications camera lens filter assembly images camera hood with digital camera bracket uv epi-illumination interface acquisition software with digital camera analysis software band matching digital camera auto zoom digital zoom and standard uv/ir filter 7.1 megapixels or greater cc-80 analysis cabinet with gl-1101 camera adapter ebf-280c 8-watt mw/sw lamp usb a/v output ntsc or pal solution disk for automated image capture imageaide for gels colonies spots blots manual band quantification model gl-4101b gl-4151b product epi-digicam band matching system epi-digicam band matching plus camera kit/cabinet gl-4200b/cc-80 gl-4200b/cc-80 acquisition solution disk solution disk analysis gl-3300 gl-3300 transilluminator optional tvc-312r 1

[close]

p. 15

genelinetm imaging systems imagesourcetm image acquisition software · provides fully automated control of ccd camera functions for both focusing and acquisition · on-screen display of system status · real-time live image positioning and manipulation · icon-driven single-click control of software capabilities · direct link to imageaide analysis software · saves images in wide range of file formats imagesource software is perfect for acquiring annotating and printing of laboratory images utilizing a simple-to-use interface offering a wide range of icon-based functions imagesource provides the ultimate image management imagesource is available as an acquisition constituent of imageeze system or sold separately as imagesource data acquisition kit the kit includes the interface card acquisition board ccd camera cables and imagesource software software application window and toolbars image capture toolbox offers user-friendly configuration controls for extended dynamic range edr and neutral field correction nf capabilities include controls for live/freeze/snap capture camera integration saturation detection for quantitative applications brightness/contrast/gamma zooming/scrolling and 3-d view annotate image toolbar offers cropping drawing and placing annotations in the image text lines arrows and shapes can be added in different colors and sizes enhance image toolbar offers defining and cropping of image regions boundary sharpening and smoothing image speckle correction and inversion additionally images can be flipped horizontally or vertically as desired additional software features periodic version-specific updates are provided free of charge to original purchasers of imagesource software 1 geneline imaging systems · · · · · · user defined system configurations for creating and saving default image settings complete help section located in standard toolbar is accessible anytime during use of imagesource file menu for acquiring importing and manipulating previously saved images includes full windows-based document functions such as cut copy paste and undo report and printing settings are also accessible single-click icon to send image directly to imageaide for analysis.

[close]

p. 16

genelinetm imaging systems imageaidetm image analysis software · icon-based software for ultimate simplicity providing complete and accurate image analysis instantly · user-control image brightness contrast and gamma settings · manual and automated track band peak lane and edge finding even on indistinct and smiling bands · automatic baseline correction and band manipulation · band matching capabilities · track labeling and profile comparison with corresponding histogram peaks · integral mw libraries and display of calibration curves · linear and quadratic calibration selection · manual and automated spot location sizing and positioning with grid or non-grid formats · manual and automated background correction with compensation for grid variances · manual and automated colony counting with light and dark configurations · setting of min and max colony area sizing shape and position with ability to define areas of exclusion · manual band quantification provides user to quantify unknown bands and spots using positive and negative controls · user-configurable gel spot and colony results position rf peaks area raw quantification units ng pg or · glp compliant software including reporting · direct exporting of raw data and graph results to user provided excel and word 1

[close]

p. 17

genelinetm imaging systems imageaide is a software package used for analyzing and quantifying 1-d gel gels multi-tier protein gfp pcr visible autorad and 2-d colony spot images secured sgd default images from ccd and digital cameras are imported directly into imageaide or non-secured jpg bmp tif images can be imported simply select ok for a complete fully automated analysis of the image instantly imageaide will automatically identify and display lanes bands edges then produce track profiles and results all on one window imageaide a major module of all geneline imaging systems is an analysis constituent of our component systems which include our imageeze and digicam series the software is also sold separately as imageaide analysis software periodic version-specific updates are provided free of charge to original purchasers of imageaide software features detailed parameters to promote multi-user control researchers can create and save their own preferred parameters making subsequent analyses even faster each time they log onto the software fast analysis of colonies like gel images colony plate images sgd bmp jpg tif can be imported for further analysis colony counting window this process is entirely automatic but individual colonies can be manually added or removed the results box shows the number of colonies counted and is updated continuously to show changes in colony counting affected by changes in detection parameters and defined regions fast analysis of manual band quantification and spot blot images like gel images spot/band images sgd bmp jpg tif can be imported for further analysis the analysis type selection of manual band quantification or spot blot can be made with drop-down menu spot blot/manual band quantification window when imageaide analyzes a manual band quantification image it takes measurements from defined areas boxes drawn by end-user for spot blot image it takes measurements from a defined spot spot frame for image analysis rectangular circular or free hand shapes can be placed on bands while automatic or manual grids can be placed over the spots spot/band editing similar to track editing bands and spots can be automatically or manually analyzed manual compensation for unusual regions is accomplished with unlocking spot/band image allowing individual regions to be deleted moved or adjusted for size and position results configurable results are a feature of imageaide for gel analysis graphs of mw and quantity calibrations as well as dendrogram are displayed raw data include peak height area volume band location matching comparisons matrix and coefficient tables for colony counting results include histogram of the light and dark colonies as well as raw data for both classes of colonies for spot blot and manual band quantification results table can be customized based on the amount of information to be viewed and compared reporting imageaide has a comprehensive individual reporting system to include configurable details of the sample results date and time for greater options analysis and data information can be exported to user-provided software such as word for documentation and excel for further detailing and charting the software also has its own glp reporting system for ultimate security and compliance fast analysis of gel images selected image from sample properties is imported instantly into the quantitative portion of imageaide here with one gel window view lanes bands edges and track profiles are automatically calculated and raw data in both table and graph formats are displayed for further review and analysis track editing unlocking band manipulation allows individual tracks to be deleted moved or adjusted for width and position calibration all unknown bands are compared to calibrated bands of reference track either with standardized molecular weights or defined quantities a library of standards for molecular weight is included with imageaide quantity calibration can be either manually or with automatically assigned quantities band matching peaks on sample tracks can be matched to peaks on a standard or different track cross gel track profiling analyzed tracks on different tracks and/or different gels saved with the imageaide software can be opened displayed and overlaid for profile comparison 1 geneline imaging systems

[close]

p. 18

genelinetm imaging systems geneline components and accessories camera and acquisition kits digital camera kit gl-4200b includes high-resolution digital camera with memory card 4 aa batteries usb interface cable digital camera acquisition software digital lens adapter gl-0150b close-up lens gl-0120 uv/ir filter gl-2100 and digital camera bracket gl-0200 ccd camera kit gl-4500a includes 8-bit ccd camera gl-0100 with ccd zoom lens gl-0110 ccd lens adapter gl-0140 close-up lens gl-0120 uv/ir filter gl-2100 and ccd camera bracket gl-0300 imagesource acquisition kit gl-3100 includes acquisition board cables and software imageaide analysis software gl-3300 band matching analysis software computer components gl-4300 includes thermal printer with usb and parallel interfaces and one roll of thermal paper gl-3610 case of five rolls of thermal paper replacement parts gl-1101 universal camera adapter for cc-80 gl-1201 universal camera adapter with 58mm adapter ring for cl-150 gl-0150b lens adapter for gl-4200b digital camera 58mm ring gl-0100 laboratory grade 8-bit ccd camera without cables gl-0140 lens adapter for gl-4500a ccd camera 58mm ring gl-1000 geneline hood for 8 x 10 21 x 26cm samples without camera bracket gl-1001 geneline universal darkroom hood with 58mm adapter ring gl-1100 snap-on camera adapter for cc-80 without camera bracket gl-1200 snap-on camera adapter for cl-50 without camera bracket gl-0110 zoom lens for gl-0100 8-48mm gl-2100 uv/ir filter 58mm ring gl-0120 close-up lens +2 diopter 58mm ring gl-0300 ccd camera bracket visit our website at www.spectroline.com for more detailed information about these and other spectroline products 1

[close]

p. 19

fluorescence analysis workstations product lines cm-series · lightweight portable viewing darkroom is easily transported · removable bottom panel for use with spectroline transilluminators · felt curtain provides easy access to cabinet interior · models available with or without uv light sources cx-series · large uv viewing darkroom for use with larger samples background in the context of life sciences research photo documentation enables researchers to take photographs of their electrophoretically separated nucleic acids with manual cameras such as a 35mm or a polaroid these images are documented onto print or film for further scanning and densitometric analysis viewing cabinets or darkroom hoods cameras and their adapters make up the necessary parts of any photo documentation workstation spectroline workstations utilize darkroom cabinets for convenient viewing analyzing or photographing of fluorescent samples with both epi-illumination and trans-illumination light sources our full range of cabinets provides different working sample sizes options for uv lamps and is useful for numerous applications · removable bottom panel for use with spectroline transilluminators · available with side curtains or front door providing easy access to cabinet interior cc cl-series · large uv viewing darkroom for use with larger samples · removable bottom panel for use with spectroline transilluminators · felt curtain provides easy access to cabinet interior while blocking out external light applications long wave uv forensic investigation chromatography cellulose tlc plates titration process fluorochemistry uv dosing features · provide superior fluorescence analysis and documentation · modular design with inter-changeable lamps for varying uv wavelengths · offer maximum fluorescent contrast with a wide range of uv transilluminators · effortless sample documentation with snapon camera adapters for instant film ccd and digital cameras medium wave uv gel electrophoresis gradient sampling uv dosing short wave uv uv crosslinking uv sterilization mutation studies silica tlc plates toxicology microbiology protein steroid and vitamin separations uv dosing portable viewing cabinets cm-series · · · · · flexible contoured eyepiece with a built-in uv-absorbing window for safe sample viewing felt curtain permits easy access to cabinet interior while shielding samples from external light removable bottom panel allows easy positioning over transilluminators lightweight aluminum construction provides transportable darkroom cabinet dimensions w xlxh 9 x 12 x 6.5 22.9 x 30.5 x 16.5 cm our portable space-saving mini-cabinets double as personal darkrooms and uv irradiating units the cm-10 model comes without a light source but can be outfitted with one of our spectroline e-series uv lamps available in 4 5 and 6-watt versions in combinations of lw mw and sw the cm-24 model is equipped with an enf-240c lamp and cm-26 model is equipped with an enf-260c 1 fluorescence analysis workstations

[close]

p. 20

fluorescence analysis workstations cm-series model cm-10 cm-24 cm-26 product cabinet only cm-10 with enf-240c cm-10 with enf-260c uv tubes with typical intensities optional 4w 365nm with 300µw/cm2 254nm with 310µw/cm2 6w 365nm with 350µw/cm2 254nm with 390µw/cm2 net weight 5.0 lbs 2.3kg 7.0 lbs 3.2kg 7.2 lbs 3.4kg fluorescence analysis cabinets cx-series · specially designed for 20 x 20 cm gels and tlc plates · units are equipped with individual long wave medium wave and short wave uv tubes including an internal white light bulb · flexible contoured eye piece with a built-in uv-absorbing window to increase fluorescent contrast and reduce eye fatigue · full size cx-20 series offer 8-watt tubes with standard uv intensity · large cx-50 series offer 15-watt tubes with high uv intensity · designed to be used with most spectroline transilluminators the cx-series uv viewing cabinets deliver standard and high uv intensities assuring maximum uv irradiance fluorescent contrast and peak efficiency designed for use with our spectroline transilluminators a removable bottom panel allows for additional transillumination source the flexible contoured viewing eyepiece with a built-in uv-absorbing sight glass provides comfort safety and to eliminate blue haze interference needed for maximum fluorescent contrast for convenience these workstations feature push-button wavelength selection and internal white light control to protect samples from unwanted light exposure all power buttons in these units are color-coded for convenience cx-21 cx-20 cx-50 series the cx-20 and cx-21 are equipped with internal 8-watt lw 365nm sw 254nm and white light tubes while the double-tiered soft rubber curtains on both sides of cx-20 unit give the user easy access to the interior the flip-down access door on the cx-21 unit allows direct placement of samples from the front of the unit both the curtains and the door provide complete shielding from external light to protect the user from accidental uv exposure cx-21 features an interlock mechanism that turns off uv sources when door is open the cx-50 series cabinets each with standard 25-watt white light bulb are equipped with separate internal 15-watt lw 365nm mw 312nm and/or sw 254nm tubes depending on the model each unit is made of a rugged metal housing with an adjustable 3-position sample platform and double-tiered soft rubber curtain that shields samples from external light cx-20 series · overall housing dimensions w xlxh 12 x 16 x 9 30.5 x 40.6 x 22.9cm · internal white light 25-watt bulb cx-50 series · overall housing dimensions w xlxh 16.25 x 24.25 x 13.25 30.5 x 40.6 x 22.9cm · internal white light 25-watt bulb model cx-20 cx-21 cx-50 cx-50b cx-50f cx-50n ble-1t261 product cabinet with cur tains cabinet with metal door large cabinet large cabinet large cabinet large cabinet replacement 25-watt bulb internal uv tubes 8w 365nm/254nm 8w 365nm/254nm 15w 365nm/254nm 2 x 15w 312nm 2 x 15w 254nm 2 x 15w 365nm net weight 13.0 lbs 5.9kg 13.5 lbs 6.1kg 30.25 lbs 13.7kg 30.25 lbs 13.7kg 30.25 lbs 13.7kg 30.25 lbs 13.7kg 0

[close]

p. 21

fluorescence analysis workstations large viewing and photographic cabinets cc and cl-series · modular design allows for adaptation of interchangeable spectroline uv lamps · complete with an internal 25-watt white light bulb · specially designed port allows for safety viewing eyepiece or the substitution of a snap-on camera adapter for photography our cc-80 and cl-150 fluorescence analysis cabinets offer both superior fluorescence viewing and instant photo documentation of research findings they feature a modular design which lets you vary uv wavelengths with interchangeable spectroline uv lamps maximize fluorescent contrast by adding a spectroline transilluminator and document your results with snap-on spectroline camera adapters visible epi-illumination is provided by an internal 25-watt white light bulb rugged and durable both cabinets are made of aluminum with a chemical-resistant polyurethene coating felt curtains permit easy access to the interior while blocking out ambient light all light control switches are conveniently located on the top of the cabinets when maximum intensity is desired dual lamps can be operated simultaneously in those cabinets that accept two lamps cc-80 cabinets accommodate our e-series lamps 6 or 8-watt single or double tube models whereas cl-150 cabinets accommodate our x-series lamps 15-watt single or double tube models the spacious cc-80 cabinet accepts standard gels and up to two 8 x 8 20 x 20cm tlc plates while the even roomier cl-150 can easily accommodate larger gels and up to four 8 x 8 plates the cc-81 workstation includes cc-80 cabinet with enf-280c lamp with separate 8-watt lw 365nm and sw 254nm uv tubes whereas the cl-151 includes cl-150 cabinet with xx-15nf lamp with separate 15-watt lw and sw uv tubes cc-80 series · overall housing dimensions w xlxh 17.5 x 20.25 x 9.75 44.5 x 51.4 x 24.8cm · net weight 11.5 lbs 5.2kg cl-150 series · overall housing dimensions w xlxh 19.5 x 24.25 x 12.75 49.5 x 61.6 x 32.4cm · net weight 15.0 lbs 6.8kg model cc-80 cc-81 cl-150 cl-151 ble-1t261 product cabinet with white light bulb cc-80 cabinet with enf-280c lamp cabinet with white light bulb cl-150 cabinet with xx-15nf lamp replacement 25-watt white light bulb uv tubes optional e-series lamp 8w 365nm/254nm optional x-series lamp 15w 354nm/254nm accessories for photo documentation workstations · · · · for use with all spectroline cabinets spectronics carries a full line of uv lamps and transilluminators as well as additional camera adapters/filters for cc-80 and cl-150 photo documentation workstations refer to appropriate sections for complete listings publication-quality images custom snap-on adapters for both cc and cl-series compatible with polaroid and slr cameras gelatin filters provide contrast for specific film documentation spectroline camera adapters help produce publication-quality digital images prints transparencies or negative of samples with light-tight custom snapon camera adapters they make the cc-80 and cl-150 instantly compatible with polaroid ds-34 cu-5 and mp-4 camera systems as well as 35mm slr camera simply snap any of the light-tight adapters onto the cabinet in place of the uv-absorbing eyepiece then add an applicable gelatin filter to produce prints transparencies or negatives of samples 1 fluorescence analysis workstations

[close]

p. 22

fluorescence analysis workstations camera adapters · port opening dimensions l x w 8 x 6.5 20.3 x 16.5 cm model ca-35 ca-cu5 ca-cu5/l ca-ds34 ca-ds34/l ca-ds34/m ca-ds34/lm ca-mp4 camera/field of view 35mm slr 8 x 10 polaroid cu-5 8 x 10 polaroid cu-5 8 x 10 polaroid ds-34 8 x 10 polaroid ds-34 8 x 10 polaroid ds-34 4 x 5 polaroid ds-34 4 x 5 polaroid mp-4 cabinet cc-80 and cl-150 cc-80 cl-150 cc-80 cl-150 cc-80 cl-150 cc and cl-150 series height 0.625 1.6cm 6.625 17.0cm 3.625 9.2cm 4.0 10.2cm 1.0 2.5cm 3.0 7.6cm 5.0 12.7cm 6.125 15.6cm net weight 0.5 0.75 0.75 0.75 0.75 1.0 1.0 1.0 lb lb lb lb lb lb lb lb 0.2kg 0.3kg 0.3kg 0.3kg 0.3kg 0.5kg 0.5kg 0.5kg gelatin wratten filters model gf-2a gf-22 gf-25 product clear filter orange filter red filter film type color black white black white contrast absorbs uv no contrast absorbs uv and increases contrast absorbs uv and increases contrast polaroid camera and filters · ds-34 polaroid instant camera with 105mm f/4.5 lens and pistol grip · uses color type 679 and b&w type 667 with 31/4 x 41/4 film format · various photographic solid glass filters to fit ds-34 40.5mm screw-on type for adding contrast as well as enhancing detailed clarity to bands and images photodoctm hoods · full line of camera hoods with attached lens for 4-5mm focus inside hood · available with varying internal dimensions · perfect for use with spectroline transilluminators polaroid camera hoods model ch-710 ch-810 ch-1012 ch-1013 ch-1216 ch-1314 ch-1317 ch-1520 ch-1623 ch-1723 ch-1927 ch-2128 ch-2330 3 internal dimensions 16 x 4 5 16 9.7 x 11.8cm 3 7 8 x 3 15 16 7.9 x 10cm 3 13 16 x 4 11 16 9.65 x 11.9cm 4 15 16 x 5 9 16 11 x 14.2cm 6 1 8 x 4 7 16 11.3 x 15.6cm 5 3 16 x 5 9 16 13.1 x 14.2cm 5 x 6 9 16 12.7 x 16.7cm 5 x 7 1 16 12.7 x 17.9cm 5 3 16 x 8 11 16 14.8 x 22.1cm 6 3 4 x 9 7 16 17.2 x 24cm 7 3 16 x 10 3 16 18.2 x 25.9cm 8 7 16 x 10 5 8 21.5 x 27cm 8 3 8 x 11 3 16 21.3 x 28.4cm 13 image magnification 0.91 0.90 0.80 0.69 0.63 0.70 0.55 0.55 0.43 0.41 0.36 0.35 0.35 polaroid camera and filters model ds-34 sf-2a sf-8 sf-15 sf-23a sf-25 sf-58 product polaroid camera clear filter yellow filter light orange filter orange filter red filter green filter polaroid film type any color black white black white black white black white black white contrast absorbs uv no contrast absorbs uv contrast for coomassie blue stained samples absorbs uv contrast for fluorescent/sybr green stained gels absorbs uv contrast for fluorescent/et br stained gels absorbs uv contrast for fluorescent stained gels absorbs uv contrast for silver stained gels

[close]

p. 23

standard intensity ultraviolet lamps hand-held uv lamps features · choice of 4-watt 5-watt 6-watt and 8-watt models · available in all uv wavelengths lw mw sw as well as germicidal lamps · single and dual wavelength combinations · filtered and unfiltered lw uv tubes · offered with or without filter assemblies · compact and lightweight of anodized aluminum housing · convenient carrying handle that snaps off for use with lamp stand single wavelength e-series long wave lw uv-a 365nm · integrally filtered tube blb or unfiltered tube bl · with or without filter assembly fa model ea-140 en-140 en-140l ea-240 ea-150 ea-160 en-160 en-160l ea-180 en-180 en-180l en-280l uv tubes one 4-watt blb ble-220b one 4-watt bl ble-270w one 4-watt bl ble-270w with fa two 4-watt blb ble-220b one 5-watt blb ble-5t365b one 6-watt blb ble-480b one 6-watt bl ble-6t365 one 6-watt bl ble-6t365 with fa one 8-watt blb ble-760b one 8-watt bl ble-8t365 one 8-watt bl ble-8t365 with fa two 8-watt bl ble-8t365 with fa filter assembly 2f003 2f005 2f082 2f082 dimensions w xlxh 3.25 x 7 x 2.5 8.3 x 17.8 x 6.4cm 3.25 x 7 x 2.5 8.3 x 17.8 x 6.4cm 3.25 x 8 x 2.5 8.3 x 20.3 x 6.4cm 3.25 x 7 x 2.5 8.3 x 17.8 x 6.4cm 3.25 x 8 x 2.5 8.3 x 20.3 x 6.4cm 3.25 x 10.25 x 2.5 8.3 x 26.0 x 6.4cm 3.25 x 10.25 x 2.5 8.3 x 26.0 x 6.4cm 3.25 x 10.25 x 2.5 8.3 x 26.0 x 6.4cm 3.25 x 13.25 x 2.5 8.3 x 33.7 x 6.4cm 3.25 x 13.25 x 2.5 8.3 x 33.7 x 6.4cm 3.25 x 13.25 x 2.5 8.3 x 33.7 x 6.4cm 3.25 x 13.25 x 2.5 8.3 x 33.7 x 6.4cm net weight 1.75 1.75 2.0 1.75 2.0 2.0 2.0 2.5 2.25 2.25 2.75 2.75 lbs lbs lbs lbs lbs lbs lbs lbs lbs lbs lbs lbs 0.8kg 0.8kg 0.9kg 0.8kg 0.9kg 0.9kg 0.9kg 1.1kg 1.0kg 1.0kg 1.2kg 1.2kg standard intensity ultraviolet lamps the compact e-series lamps provide various combinations of long medium and/or short wave uv a corrosion-resistant specular-aluminum reflector optimizes uv irradiance all sw and mw models feature a unique longlifetm filter glass for higher initial uv transmission and maximum resistance to solarization these lamps are available in choices of integrally filtered lw tubes blb or unfiltered uv tubes with or without separate filter assemblies lamps with unfiltered tubes produce higher uv intensity while double-tube units provide broader uv coverage than their single-tube counterparts color-coded on/off switches conveniently located at the top of the units put irradiance control at your fingertips the anodized-aluminum lamp housings are extremely rugged and durable all lamps include a removable carrying handle an optional lamp stand shown at right is available for hands-free operation.

[close]

p. 24

standard intensity ultraviolet lamps medium wave mw uv-b 312nm · unfiltered tube · with longlifetm filter assembly fa model eb-160c eb-180c eb-280c uv tubes one 6-watt mw ble-6t312 one 8-watt mw ble-8t312 two 8-watt mw ble-8t312 filter assembly 2f006 2f018 2f018 dimensions w xlxh 3.25 x 10.25 x 2.5 8.3 x 26.0 x 6.4cm 3.25 x 13.25 x 2.5 8.3 x 33.7 x 6.4cm 3.25 x 13.25 x 2.5 8.3 x 33.7 x 6.4cm net weight 2.5 lbs 1.1kg 2.75 lbs 1.2kg 2.75 lbs 1.2kg short wave sw uv-c 254nm · unfiltered tube · with longlifetm filter assembly fa model ef-140c ef-160c ef-180c ef-260c ef-280c uv tubes one 4-watt sw ble-2537s one 6-watt sw ble-6254s one 8-watt sw ble-8t254 two 6-watt sw ble-6254s two 8-watt sw ble-8t254 filter assembly 2f001 2f006 2f018 2f006 2f018 dimensions w xlxh 3.25 3.25 3.25 3.25 3.25 xxxxx 8 x 2.5 8.3 x 20.3 x 6.4cm 10.25 x 2.5 8.3 x 26.0 x 6.4cm 13.25 x 2.5 8.3 x 33.7 x 6.4cm 10.25 x 2.5 8.3 x 26.0 x 6.4cm 13.25 x 2.5 8.3 x 33.7 x 6.4cm net weight 2.0 2.5 2.75 2.75 2.75 lbs lbs lbs lbs lbs 0.9kg 1.1kg 1.2kg 1.2kg 1.2kg dual wavelength e-series · unfiltered long medium and short wave tubes · with longlifetm filter assembly fa long wave uv-a 365nm short wave uv-c 254nm model enf-240c enf-260c enf-280c uv tubes one 4-watt bl ble-270w one 4-watt sw ble-2537s one 6-watt bl ble-6t365 one 6-watt sw ble-6254s one 8-watt bl ble-8t365 one 8-watt sw ble-8t254 filter assembly 2f001 2f006 2f018 dimensions w xlxh 3.25 x 8 x 2.5 8.3 x 20.3 x 6.4cm 3.25 x 10.25 x 2.5 8.3 x 26.0 x 6.4cm 3.25 x 13.25 x 2.5 8.3 x 33.7 x 6.4cm net weight 2.0 lbs 0.9kg 2.5 lbs 1.1kg 2.75 lbs 1.2kg long wave uv-a 365nm medium wave uv-b 312nm model enb-260c enb-280c uv tubes one 6-watt bl ble-6t365 one 6-watt mw ble-6t312 one 8-watt bl ble-8t365 one 8-watt mw ble-8t312 filter assembly 2f006 2f018 dimensions w xlxh 3.25 x 10.25 x 2.5 8.3 x 26.0 x 6.4cm 3.25 x 13.25 x 2.5 8.3 x 33.7 x 6.4cm net weight 2.5 lbs 1.1kg 2.75 lbs 1.2kg medium wave uv-b 312nm short wave uv-c 254nm model ebf-260c ebf-280c uv tubes one 6-watt mw ble-6t312 one 6-watt sw ble-6254s one 8-watt mw ble-8t312 one 8-watt sw ble-8t254 filter assembly 2f006 2f018 dimensions w xlxh 3.25 x 10.25 x 2.5 8.3 x 26.0 x 6.4cm 3.25 x 13.25 x 2.5 8.3 x 33.7 x 6.4cm net weight 2.5 lbs 1.1kg 2.75 lbs 1.2kg germicidal e-series · unfiltered short wave uv-c tubes without filter assembly model ef-140 ef-160 ef-180 uv tube one 4-watt sw ble-2537s one 6-watt sw ble-6254s one 8-watt sw ble-8t254 filter assembly dimensions w xlxh 3.25 x 7 x 2.5 8.3 x 17.8 x 6.4cm 3.25 x 10.25 x 2.5 8.3 x 26.0 x 6.4cm 3.25 x 13.25 x 2.5 8.3 x 33.7 x 6.4cm net weight 1.75 lbs 0.8kg 2.0 lbs 0.9kg 2.25 lbs 1.0kg accessories for e-series lamps se-140 ch-180 lamp stand carrying handle

[close]

p. 25

standard intensity ultraviolet lamps uv bench and display lamps features · choice of 15-watt 30-watt and 40-watt models · available in all uv wavelengths lw mw and sw as well as germicidal lamps · single and double-tube combinations · filtered uv-a and unfiltered uv tubes · offered with or without filter assemblies · 15-watt models with anodized aluminum housing · 30 and 40-watt models with enameled sheet metal housing · outfitted with sturdy metal brackets for easy overhead mounting x-series lamps are ideally suited for applications where high-intensity wide-area uv coverage is required constructed of rugged metal with sturdy mounting brackets these units are available in various combinations of long medium and/or short wave uv the complete line also offers lamps in a wide choice of various intensities sizes and-wattage including single or double uv tubes a corrosion-resistant aluminum reflector optimizes uv irradiance while all short and medium wave models feature our unique longlifetm filter glass to ensure high initial uv intensity these versatile lamps are also a key component of our cl-150 uv photo documentation system they offer easy wavelength interchangeability making this system ideal for numerous applications requiring a darkened environment single wavelength x­series long wave lw uv-a 365nm · integrally filtered tube blb or unfiltered tube bl · with or without filter model x-15a x-15n x-30 x-40 xx-15a xx-15n xx-40 xx-40n uv tubes one 15-watt blb ble-1800b one 15-watt bl ble-1t151 with filter one 30-watt blb ble-5000b one 40-watt blb ble-7900b two 15-watt blb ble-1800b two 15-watt bl ble-1t151 with filter two 40-watt blb ble-7900b two 40-watt blb ble-7900b with filter filter -2f501 2f501 -2f951 dimensions w xlxh 4.5 x 18.75 x 3.5 11.4 x 47.6 x 8.9cm 4.5 x 18.75 x 3.5 11.4 x 47.6 x 8.9cm 6 x 36 x 4 15.2 x 91.4 x 10.2cm 6 x 48 x 4 15.2 x 121.9 x 10.2cm 4.5 x 18.75 x 3.5 11.4 x 47.6 x 8.9cm 4.5 x 18.75 x 3.5 11.4 x 47.6 x 8.9cm 6 x 36 x 4 15.2 x 91.4 x 10.2cm 6 x 36 x 4 15.2 x 91.4 x 10.2cm net weight 4.5 6.25 9.25 12.0 5.5 6.5 14.0 17.5 lbs lbs lbs lbs lbs lbs lbs lbs 2.0kg 2.8kg 4.3kg 5.4kg 2.5kg 2.9kg 6.4kg 7.9kg standard intensity ultraviolet lamps