Catálogo Amerex Instruments

 

Embed or link this publication

Popular Pages


p. 1



[close]

p. 2

2 table of contents autoclaves 3 autoclaves without drying 4-8 autoclaves with drying 9-11 autoclave accessories 12 steadyshake gryomax incubator shakers 13 steadyshake incubator shakers benchtop 757 757l 14 gryomax incubator shakers benchtop chest-type 15 gyromaxtm incubator shakers benchtop chest-type specifications 17 gyromaxtm incubator shakers 17 gyromax incubator shaker 717r 18 gryomaxtm water bath shakers 22 incumaxtm incubators without refrigeration 21 incumaxtm incubators with refrigeration 22 hybridization ovens 23 incumaxtm convection ovens 24 incumaxtm water bath with circulating pump 25 circulating baths low-temperature 26 cryoprooftm 313 tube sealer 27 shaker accessories 28 amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 3

3 portable top-loading autoclaves and sterilizers amerex instruments inc offers 13 autoclave models to meet the sterilization needs of most biological research laboratories they are fully user friendly systems automatic stand-alone microprocessorcontrolled programmable and self-contained all models incorporate a built-in steam generator and plug into a standard 120vac or 220vac power outlet thereby eliminating costly set-up charges water for steam generation is poured directly into the chamber after sterilization steam is vented automatically into a plastic bottle in front of the autoclave a warming cycle keeps sterilized agar from solidifying and also can be used for melting sterilized agar amerex s top-loading autoclaves are labeled and distributed for research use only amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 4

4 autoclaves without drying top-loading design saves space-ideal for tall articles hv-series portable top-loading with advanced safety and user-friendly features space-saving design with lid opening upward programmable auto-start for initiating a cycle up to 1 week later dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°c automatic air purging by a microprocessor prevents over-pressurization during a cycle one-touch lever to easily open and close chamber lid programmable rate of steam exhaust door-closure sensor provides a prompt and cycle will not start unless the door is closed properly in-process display shows status and progress of sterilization cycle agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature unique accessory floating sensor to monitor load temperature sterilization timer is activated only when load temperature reaches set temperature agar melting mode for rapidly melting agar and maintaining it at liquid temperature or for a hot and faster startup memory backup system retains user-programmed parameters even in case of power failure control panel catalog number temp operating range temp display range temp warming range temp agar dissolution gauge pressure operating range maximum allowable timer sterilization delayed auto-start overall dimensions w xdxh chamber dimensions diameter x height programs 1.for agar 2.for liquids 3.for solids 4.for melting agar faster start-up safety devices power source power consumption at-hv-25 105oc to 126oc 10oc to 128oc at-hv-50 at-hv-85 at-hv-110 105oc to 135oc 10oc to 137oc oc to 60oc 45 heating at 60oc to 100oc for up to 1 hour temp and time programmable followed by 45oc to 60oc temp programmable for up to 20 hours 3 to 22 psi gauge 0.02 to 0.148 mpa 3 to 30 psi 0.02 to 0.206 mpa 27 psi 0.186mpa 38 psi 0.26mpa 1 to 250 minutes program autoclave to start 1 minute to 7 days later 19 x 18 x37 in 20 x 21 x 41 in 26 x 25.6 x39 in 26 x 26 x 46 in 48 x 46 x 95 cm 51 x 53 x 104 cm 66 x 65 x 100 cm 66 x 65 x118 cm 25 liters 50 liters 85 liters 110 liters 9.4 x 21.6 in 11.8 x 28 in 16.5 x 24 in 16.5 x 31 in 24 x 55 cm 30 x 71 cm 42 cm x 61.5 cm 42 x 79.5 cm heating sterilization exhaust from no exhaust to slow programmable warming completion heating sterilization exhaust from no exhaust to slow programmable completion heating sterilization exhaust from no exhaust to slow programmable completion rapid melting at 60oc to 100oc temperature and time programmable maintain at 45oc to 60oc temperature programmable completion dual-sensing safety lid interlock over-pressure/temperature/lower-water power cutoff mechanical pressure relief valve microprocessor-controlled pressure relief valve lidclosure detector over-current detector and circuit breaker 120v 50/60 hz 220v available 220v 1500 watts 2000 watts 2000va 3000 watts 3000va 4000 watts 4000va 1500va amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 5

5 options 1 load sensor 2 digital printer 3 data logger 4 cooling fan autoclaves without drying economical versions of hv-50 hve-50 self-contained portable autoclaves with auto exhaust warming cycles space-saving design with lid opening upward agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°c agar melting mode for melting agar and maintaining it at liquid temperature or for a hot faster start-up one-touch lever to easily open and close chamber lid in-process display shows the status and the progress of sterilization cycle door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly hve-50 size 50 liters 11.8 d 28.0 h control panel catalog number temperature operating range temperature display range temperature warming range gauge pressure operating range gauge maximum allowable timer sterilization dimensions overall w xdxh chamber d x h safety devices programs 1 for agar/liquids also for melting agar or for faster startup 2 for liquids/solids 3 for solids stainless steel accessories factory or field installed power requirements at-hve-50 105ºc to 135ºc 5ºc to 137ºc 45ºc to 60ºc 3 to 30 psi 0.021 to 0.206mpa 38 psi 0.26mpa 1 to 250 minutes 20.1 x 20.8 x 40.9 51 cm x 53 cm x 104 cm 50 liters 11.8 x 28 30 cm x 71 cm dual-sensing lid interlock over-pressure power cutoff over-temperature power cutoff low-water power cutoff mechanical pressure relief valve lid-closure detector overcurrent detector and circuit breaker heating sterilization auto steam exhaust or ambient cooling programmable warming completion heating sterilization auto steam exhaust or ambient cooling programmable completion heating sterilization auto exhaust fast completion mesh wire baskets buckets pails and test tube racks data logger 120v 50/60 hz single phase 220v available on request 2000 watts 2000 va amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 6

6 autoclaves without drying economical versions of hv-85 and hv-110 hva-series portable autoclaves with cooling fan advanced safety/user-friendly features space-saving design with lid opening upward standard built-in cooling fan for faster post sterilization cooling dual lid safety interlock prevents lid opening when a cycle is in progress the chamber is pressurized or the temperature exceeds 97°c agar sterilization mode sterilizes agar and then automatically keeps it warm to prevent it from solidifying one-touch lever to easily open and close chamber lid agar melting mode for rapidly melting agar and then automatically maintaining it at liquid temperature or for a hot and faster start-up door-closure sensor prevents a cycle from starting unless the door is closed properly in-process display shows the status and the progress of sterilization cycle hva-85 85 liters 16.5 d x 24.2 h hva-110 110 liters 16.5 d x 31.3 h control panel catalog number temperature operating range temperature display range agar warming range gauge pressure maximum allowable operating range timer sterilization dimensions overall w xd xh dimensions chamber d x h at-hva-85 105ºc to 135ºc 137ºc at-hva-110 after sterilization agar can be maintained from 45ºc to 60ºc programmable to prevent coagulation for up to 20 hours 38 psi 0.26mpa 3 to 30 psi 0.021 to 0.206mpa 1 to 250 minutes 26.0 x 25.6 x 39.4 66 cm x 65 cm x 100 cm 85 liters 16.5 x 24.2 42.0 cm x 61.5 cm 26.0 x 25.6 x 46.4 in 66 cm x 65 cm x 118cm 110 liters 16.5 x 31.3 42.0 cm x 79.5 cm safety devices programs 1 for agar 2 for liquids 3 for solids accessories stainless steel factory or field installed power source dual-sensing lid interlock over-pressure power cutoff over-temperature power cutoff low-water power cutoff mechanical pressure relief valve microprocessorcontrolled pressure relief valve lid-closure detector over-current detector and circuit breaker heating sterilization auto steam exhaust or ambient cooling programmable warming completion heating sterilization auto steam exhaust or ambient cooling programmable completion heating sterilization auto exhaust fast completion mesh wire baskets buckets pails and test tube racks data logger 208v 220v 240v 50 60 hz single phase amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 7

7 power consumption 3000 watts 3000va 4000 watts 4000va amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 8

8 autoclaves without drying convenient one-button opening and closing of lid hg-series hirayama autoclaves with an innovative feature just press a button to automatically open the lid or close and lock it automatic lid opening and closing button replaces a foot pedal new body design with larger diameter and shorter height safety interlock senses pressure and temperature and prevents lid from opening when the chamber is pressurized temperature is too high and also during a cycle programmable auto-start for running a cycle up to 99 hours later efficient 15-liter steam condenser eliminates steam exhaust into the lab over-flow lamp indicates that the drain bottle is full and ready to be emptied built-in fan for faster post-sterilization cooling and shorter completion time selectable rate of steam venting after sterilization programmable time for air removal before sterilization large control and display panel improves functionality and shows the progress of the sterilization cycle control panel catalog number overall w xdxh chamber d x h temperature range sterilization timer agar warming range delayed auto-start cooling fan air removal timer steam venting temperature for release of lid interlock sterilization program cycles additional cycles for agar dissolution agar dissolution protocol safety features steam condenser drain water bottle power requirements power consumption at-hg-50 19.7 x 27.2 x 35.0 45.5 cm x 6.91 cm x 89.0 cm 50 liters 14.3 x 18.2 36.4 cm x 47.0 cm at-hg-80 19.7 x 27.2 x 40.6 45.5 cm x 69.1 cm x 103.0 cm 76 liters 14.3 x 28.7 36.4 cm x 73.0 cm 105°c to 135°c 1 to 300 minutes after sterilization agar can be maintained from 45°c to 60°c programmable for up to 24 hours to prevent coagulation program autoclave to start 1 to 99 hours later switch to turn fan on or off programmable 3 to 9 minutes after temperature has reached 97°c selectable from no venting and three other venting rates programmable 60°c to 97°c for greater safety and flexibility 1 liquid cycle 2 agar liquid with warming cycle and 3 solid cycle cycle for dissolving and keeping agar warm no sterilization initially at 60°c-100°c for 1-60 min then at 45°c-60°c for up to 24 hrs circuit breaker with gfci low-water power cut-off over-temp power cutoff overpressure power cut-off safety valve sensor for improper lid closing 15-liter water tank 2 liters 120v or 220v 50/60 hz single phase 2.0kw optional 3.0kw for 220v only amerex instruments amerexinst.com 1-888-263-7392 220v 50/60 hz single phase 3.9 kw

[close]

p. 9

9 autoclaves without drying classic reliable workhorse ha-300mw self-contained portable top-loading autoclave with continuous operation top loading design is ideal for the sterilization of media and other liquids in tall flasks and bottles deep chamber for accommodating fermentors and bioreactors space-saving stand-alone unit occupies minimal floor space and can fit conveniently into many locations in the laboratory full-count sterilization guarantees sterilization at the preset temperature and time timer pauses if chamber temperature falls 1°c below the preset temperature liquid cycles with slow exhaust or natural cooling for liquids and solids without drying agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature full-count sterilization guarantees sterilization at the preset temperature for the preset time micro-processor controlled for precise sterilization audio/visual alarms and on-board diagnostics for rapid repair timer range 1 to 999 minutes or continuous catalog number temperature operating range temperature display range gauge pressure operating range maximum allowable timer sterilization dimensions overall w xdxh dimensions chamber d x h safety devices programs 1 for agar 2 for agar 3 for liquids 4 for solids 5 for melting agar accessories stainless steel factory or field installed power source power consumption at-ha-300mw 105°c to 126°c 5°c to 129°c 3 to 22 psi 0.021 to 0.152mpa 38 psi 0.26mpa 1 to 999 minutes or continuous 17 x 21 x 42 43 cm x 53 cm x 107 cm 50 liter 11.8 x 26.4 30 cm x 67 cm over-pressure/over-temperature low-water power cutoff mechanical pressure relief valve over-current detector and circuit breaker sterilization slow pulse exhaust warming completion sterilization natural cooling warming completion sterilization slow pulse exhaust completion sterilization natural cooling completion warming at 45°c to 80°c completion mesh wire baskets buckets pails and test tube rack data logger 120v 50/60 hz single phase 220v available on request 2000 watts 2000 va amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 10

10 autoclaves with drying vacuum pump for most efficient sterilization hvp-50 top-loading autoclave with fully automatic drying cycle using heat and vacuum space-saving design with lid opening upward fully automatic drying cycle for solid loads uses heat and vacuum for faster and more efficient drying lid safety interlock prevents lid opening when a cycle is in progress the chamber is pressurized or when the temperature exceeds 97°c pre-vacuum cycle vacuum pump removes air from the chamber when sterilizing solids such as glassware and pipette tips thereby eliminating cold spots and ensuring faster and more efficient sterilization one-touch lever to easily open and close chamber lid liquid cycle for media and agar process display shows the program progress selected and status of the sterilization cycle cycle for wastes and glassware without drying bacteria filter reduces re-contamination door-closure sensor prevents a cycle from starting unless the door is closed properly hvp-50 size 50 liters 11.8 d 28.0 h catalog number temp range temp display range operating range gauge pressure timer sterilization timer drying overall dimensions w xdxh chamber dimensionsd x h safety devices programs 1 for solids with drying 2 for wastes/solids without drying 3 for liquids/agar 4 drying without sterilization accessories stainless steel factory or field installed power source power consumption at-hvp-50 105ºc to 135ºc 5ºc to 140ºc 3 to 28.4 psi 0.2 to 2.0 kg/cm² 1 to 250 minutes 1 to 90 minutes 20.1 x 24.8 x 40.9 51 x 63 x 104 cm 50 liter ,11.8 x 28 30 cm x 71 cm temperature and pressure-sensitive lid interlock over-pressure/overtemperature/low-water power cutoff mechanical pressure relief valve lid-closure detector over-current detector and circuit breaker with ground fault circuit interrupter heating and air removal from chamber by vacuum pump pre-vac sterilization water and steam exhaust fast drying by heat and vacuum completion heating pre-vac sterilization steam exhaust fast completion heating sterilization auto steam exhaust programmable rates or ambient cooling w/o steam exhaust completion drying with heat and vacuum time programmable completionfor additional drying after program #1 if desired mesh wire baskets buckets pails and test tube racks data logger 120v 50/60 hz single phase 220v/240v available on request 2000 watts 2000 va amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 11

11 autoclaves with drying vacuum pump for most efficient sterilization in larger loads hrh-110 front-loading autoclave with fully automatic drying cycle using heat vacuum front-loading design fully automatic operation from start to finish with or without drying one-touch door closing lever opens and closes the door easily surely and safely pre-vacuum cycle vacuum pump removes air from the chamber when sterilizing solids such as glassware and pipette tips thereby eliminating cold spots and ensuring faster and more efficient sterilization drying by heat and vacuum increases drying efficiency and reduces cycle times additional drying mode for complete drying without having to run the sterilization cycle again bacteria filter reduces re-contamination lid safety interlock prevents lid from opening during a cycle when the chamber is pressurized or when the chamber temperature is above 97°c at which superheated liquids might boil over when disturbed door-closure sensor prevents a cycle from starting unless the door is properly closed hrh-110 size 110 liters 16.5 diameter 31.3 depth catalog number outer dimensions chamber size chamber material sterilization temperature temperature display range sterilization timer drying timer sterilization and operation modes maximum allowable pressure gauge pressure thermometer digital display pressure gauge analog display drying method safety devices standard accessories options power source power consumption 1 2 3 4 hrh-110 690w x 1150d x 1385h mm 27.2w x 45.3d x 54.5h in 420 diameter x 795 depth mm 16.5 diameter x 31.3 depth in stainless steel sus304 105ºc ­ 135ºc programmable 5ºc 137ºc 1 60 min remaining time displayed 1 120 min remaining time displayed for solids sterilization and drying for solids sterilization without drying and fast exhaust for liquids sterilization without drying and slow exhaust supplementary drying if needed after sterilization mode 1 0.206mpa 2.06 kg/cm2g 5ºc 137ºc -0.1 0.4 mpa 76 cm hg-4kgf/cm2 vacuum pump and heating pressure relief valve breaker with gfic vacuum pump breaker lowwater power cut-off error detection insufficient water in the exhaust bottle wire breakage in temperature sensor over heating over cooling and over pressure door not properly locked drain hose water supply hose caster stopper operation manual data logger floating load sensor square type wire basket wire basket with solid bottom and dressing case ac220v single phase 3.2kw amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 12

12 autoclaves with drying economical autoclave with drying ha-300md self-contained portable top-loading autoclave with drying cycle top loading design is ideal for the sterilization of media and other liquids in tall flasks and bottles deep chamber for accommodating fermentors and bioreactors space-saving stand-alone unit occupies minimal floor space and can fit conveniently into many locations in the laboratory full-count sterilization guarantees sterilization at the preset temperature and time timer pauses if chamber temperature falls 1ºc below the preset temperature liquid cycles with slow exhaust or natural cooling for liquids and solids without drying drying cycle for glassware and other solid loads additional drying cycle without re-sterilization micro-processor controlled for precise sterilization internal steam generator uses purified water to generate pure steam audio/visual alarms and on-board diagnostics for rapid repair ha-300md size 50 liters 11.8 d 26.4 h catalog number temperature operating range display range gauge pressure operating range gauge maximum allowable timer sterilization drying dimensions overall w xdxh chamber d x h safety devices programs 1 for solids with drying 2 for solids w/o drying 3 for liquids 4 for additional drying accessories stainless steel factory or field installed power requirements at-ha-300md 105ºc to 126ºc 5ºc to 129ºc 3 to 30 psi gauge 0.021 to 0.21mpa 38 psi gauge 0.26mpa 1 to 999 minutes 1 to 120 minutes 17.3 x 20.5 x 42.1 in 44 x 52 x 107 cm 50 liter 11.8 x 26.4 30 cm x 67 cm over-pressure over-temperature low-water power cutoff mechanical pressure relief valve over-current detector and circuit breaker sterilization manual steam/water exhaust drying completion sterilization auto steam exhaust completion sterilization natural cooling completion drying completion mesh wire baskets buckets pails and test tube rack data logger 120v 50/60 hz single phase 220v available on request 2000 watts amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 13

13 autoclave and sterilizers accessories large selection of accessories three different types of stainless steel containers of different heights large medium and small are available for handling different loads stacking shorter containers can increase load capacity two mediumsized and three small-sized containers can fit in a given chamber a mesh wire basket is suitable for most loads including glassware and media a pail is used for media and petri dishes with liquid in them as well as to contain potential spillage from waste bags a drum has a hinged lid with a handle depending on the load it serves as a closed but not watertight trash container or as a carrying and storage case the side and bottom of the drum are perforated for better steam penetration sliding panels cover these perforations prior to and after sterilization stainless steel tube racks with various capacities up to 126 tubes per rack for 13-mm or 20-mm tubes are also available you can stack tube racks by putting them inside stacked containers stacked baskets pails and drums optional accessories also available a digital temperature and chart recorders b data logger and c floating sensor that monitors the load temperature and sterilization timer is only activated when load temperature reaches set temperature amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 14

14 steadyshaketm gyromaxtm shakers amerex s gyromaxtm and steadyshaketm orbital shakers incorporate design features that offer quiet maintenance-free shaking under a constant and reproducible temperature environment all shakers incorporate design features that offer quiet maintenance-free shaking under a constant and reproducible temperature environment eleven different models meet the needs of most biological research laboratories for shaking under a precisely controlled temperature environment and are available in four basic housing configurations features microprocessor-controlled maintenance-free brushless motor can handle flasks to 6 liters stainless steel chamber maximum temperature to 80°c 70°c for models 757 and 757l triple eccentric drive for long life and smooth quiet operation adjustable shelf for simultaneous incubation with and without shaking two units can be stacked to save space two 737rs and models 757 757l 767 767r 777 and 777r are not stackable amerex instruments amerexinst.com 1-888-263-7392

[close]

p. 15

15 steadyshaketm incubator shakers steadyshaketm 757 and 757l benchtop the steadyshaketm 757 and 757l are economical and compact benchtop incubator shakers the 757 occupies only 18 w x 19 d of space and the 757l is slightly larger 20.5 w x 25.5 d for increased flask capacity the 757 can accommodate four 2-liter erlenmeyer or two 2.8-liter fernbach flasks and the 757l five and four of these respectively the lid has a large viewing window and a microprocessor temperature controller maintains precise temperature control from 3°c above ambient to 70°c a quiet fan ensures air and temperature uniformity throughout the chamber the brushless maintenance-free drive motor generates speeds from 40 to 400 rpm 60 hz frequency which is displayed on a digital readout a triple-eccentric drive with counter-balancing weights provides smooth and quiet shaking and eliminates the inconvenience of making balancing adjustments as the load increases the timer switch affords a choice of flipping between a continuous run and a timed run up to 99 hours and 59 minutes an independent over-temperature thermostat conveniently located on the control panel prevents over-heating catalog number temperature range temperature control temperature display accuracy/uniformity safety devices drive motor speed range speed display timer chamber material platform dimensions chamber dimensions overall dimensions power source steadyshake sk-757 steadyshake sk 757l about 3°c above ambient to 70°c auto-tune microprocessor proportional integral temperature controller digital to 0.1°c ±0.1°c/±0.5°c at 37°c 1 motor stops when door is opened 2 over-temp thermostat prevents over-heating dynamically balanced triple-eccentric drive maintenance-free brushless motor 40 to 400 rpm slightly lower at 50 hz with standard 1 25mm orbit digital readout programmable up to 99 hours and 59 minutes coated steel 15.8 w x 11.8 d 400mmw x 300mmd 17.7 w x 15.0 d x 13.0 h 450mm x 380mm x 330mm 18.1 w x 19.3 d x 19.7 h 460mm x 490mm x 500mm 120v 50/60hz single phase 4a 220v available 18.1 w x 18.1 d 460mmw x 460mmd 20.1 w x 21.2d x 13.0 h 510mmw x 540mmd x 330mmh 20.5 w x 25.5 d x 19.7 h 521mmw x 648mmd x 500mmh 120v 50/60hz single phase 6a220v available flask capacity flask size ml capacity of 757 capacity of 757l 25 48 81 50 35 64 125 20 36 250 12 25 500 8 16 1000 6 9 2000 3 5 2800 2 4 amerex instruments amerexinst.com 1-888-263-7392

[close]

Comments

no comments yet