E Instruments International 2012 IAQ Monitors Catalog

 

Embed or link this publication

Description

E Instruments IAQ Monitors Catalog

Popular Pages


p. 1

e instruments international 2013 iaq monitors catalog www.e-inst.com f 215-750-1399 p 215-750-1212 langhorne pa 19047 a 402 middletown blvd ste 216

[close]

p. 2

ami 300 supplied with calibration certificate multifunctional iaq analyzer p a connection interchangeable measurement modules 1 instrument more than 1 range and 1 parameter available wireless connection instrument pc instrument probe smart-plus system probes automatically recognized when connected to the instrument the all-in-one tool ami 300 build your own kit dimensions mm front view side view 85.4 1 +

[close]

p. 3

functions manometer pressure automatic or manual self-calibration selection of units pressure integration 0 to 9 point/point automatic point/point automatic average minimum maximum values hold standard deviation storage datalogger-10 multi-parameters recording manual and automatic storage memory up to 12,000 measurement points or 50 datasets user-friendly with printing of customized report management of instruments pool follow-up of calibration periods intervention planning wired or wireless interface technical features sensing elements pressure modules piezoresistive sensor overpressure allowed ±500 pa 250 mbar overpressure allowed ±2500 pa 500 mbar overpressure allowed ±10,000 pa 1,200 mbar overpressure allowed ±500 mbar 2 bar overpressure allowed ±2,000 mbar 6 bar hotwire thermistance with a negative temperature coefficient ambient temperature pt100 1/3 din Ø 70 and 100 mm vane probes hall effect sensor ambient temperature pt100 class a Ø 14 mm vane probe proximity sensor ambient temperature pt100 class a hygrometry/temp probe capacitive sensor pt100 1/3 din thermocouple probes type k j and t class 1 pt100 probes smart-plus pt100 class 1/3 din climatic conditions module hygrometry capacitive sensor temperature semiconductor sensor air pressure piezoresistive sensor air quality probes co2 ndir sensor co electrochemical sensor temperature pt100 class a hygrometry capacitive sensor climatic conditions module hygrometry capacitive sensor temperature semiconductive sensor air pressure piezoresistive sensor multifunction probe air velocity thermistance with a negative temperature coefficient hygrometry/temp capacitive sensor pt100 1/3 din tachometry probe optical optical sensor contact optical probe with etc adaptor instrument connections on the top 2 secured mini-din connectors for smart-plus probes left side 1 usb port for eig cable only 1 power supply plug thermocouple 4 inputs for compensated miniature plug of thermocouple type k j or t class 1 as per iec 584-3norm pressure 2 pressure connectors Ø 6.2 mm made of nickelled brass 2 threaded pressure connectors Ø 4.6 mm made of nickelled brass 1 thermocouple temperature input for miniature connectors current voltage module 2 stereo jacks graphic display 320x240 pixels dim 70 x 52 mm color display display of 6 measurements including 4 simultaneously ip54 abs shock-proof metal-coated 5 keys 1 joystick electromagnetical compatibility nf en 61326-1 norm 4 alkaline batteries 1.5v lr6 included neutral gas from 0 to 122°f 0 to 50°c from 0 to 176°f 20 to +80°c adjustable from 0 to 120 min 13.4 oz 380g english french dutch german italian spanish portuguese swedish norwegian finn danish air velocity and airflow selection of pitot tube debimo blades hot-wire or factor for other sensing elements selection of duct type selection of units point/point automatic point/point automatic average manual or automatic temperature balancing manual air pressure balancing k2 factor minimum maximum values hold standard deviation storage thermo-hygrometer hygrometer selection of units minimum maximum values and hold function storage psychrometer dew point wet temperature enthalpy absolute temperature minimum maximum values and hold function storage wbgt index for hygrometry probe with black ball calculation of comfort index inside outside storage air quality climatic conditions module selection of units minimum maximum values and hold function storage module connections air quality probes audible alarm 2 setpoints co maximum selection of units minimum maximum values and hold function storage current voltage module adjustable ranges minimum maximum values and hold function storage display housing keypad conformity power supply operating environment operating temperature storage temperature auto shut-off weight languages thermometer thermocouple module pt100 and thermocouple temperature probes dynamic delta t selection of units minimum maximum values and hold function alarme upper and lower setpoints storage

[close]

p. 4

specifications pressure measuring units inh 2 o pa mmh 2 o mbar hpa mmhg dapa measuring range from from from from from 0 0 0 0 0 to to to to to ±500 pa ±2500 pa ±10,000 pa ±500 mbar ±2000 mbar ±0.2 ±0.2 ±0.3 ±0.3 accuracy ± 100 pa ±0.2 reading ±0.8pa beyond ±0.2 readi ng ±1.5pa resolutions 0.1 pa from -100 to +100 pa 1 pa beyond of reading ±2pa of reading ±10pa of reading ±0,5mbar of reading ±2mbar 1pa 1pa 0.1mbar 1mbar current/voltage v ma from 0 to 2.5 v from 0 to 10 v from 0 to 4/20 ma k from -200 to +1,300°c j from -100 to +750°c t from -200 to +400°c from 5 to 95%rh from -20 to +80°c from 800 to 1100 hpa from 0.15 to 3 m/s from 3 to 30 m/s from -20 to +80°c from 0 to 99,999 m 3 /h from 0.25 to 3 m/s from 3 to 35 m/s from -20 to +80°c from 0 to 99,999 m 3 /h from 0 to 3 m/s from 3 to 35 m/s from -20 to +80°c from 0 to 99,999 m 3 /h from 0.8 to 3 m/s from 3 to 40 m/s from 0 to 99,999 m 3 /h from -20 to +80°c from 2 to 5 m/s from 5.1 to 100 m/s from 0 to 99,999m3/h from 4 to 20 m/s from 21 to 100 m/s from 0 to 99,999m3/h ±2mv ±10mv ±0.01ma ±1.1°c or ±0.4 of reading ±0.8°c or ±0.4 of reading ±0.5°c or ±0.4 of reading see datasheet for interchangeable measurement modules ±3 of reading ±0.03 m/s ±3 of reading ±0.1 m/s ±0.3 of reading ±0.25°c ±3 of reading ±0.03areacm 2 0.001 v 0.01 v 0.01 ma 0.1 °c 0.1 °c 0.1 °c 0.1 rh 0.1 °c 1 hpa 0.01 m/s 0.1 m/s 0.1 °c 1 m3/h 0.01 m/s 0.1 m/s 0.1 °c 1 m3/h 0.1 m/s 0.1 °c 1 m3/h 0.1 m/s 1 m3/h 0.1 °c 0.1 m/s 1 m3/h 0.1 m/s 0.1 m/s 1 m3/h thermocouple climatic conditions hygro temp air pressure °c °f %rh °c °f hpa m/s fpm km/h °c °f m 3 /h cfm l/s m 3 /s m/s fpm km/h °c °f m /h cfm l/s m 3 /s 3 hotwire standard and/or telescopic air velocity temperature airflow Ø 100 mm vane probe air velocity temperature airflow ±3 of reading ±0,1m/s ±1 of reading ±0,3m/s ±0.4 of reading ±0.3°c ±3 of reading ±0.03area cm 2 ±3 of reading ±0,1m/s ±1 of reading ±0,3m/s ±0.4 of reading ±0.3°c ±3 of reading ±0.03area cm 2 ±3 of reading ±0,1m/s ±1 of reading ±0,3m/s ±3 of reading ±0.03area cm 2 ±0.4 of reading ±0.3°c ±0.3 m/s ±0.5 of reading ±0.2m/s ±0.2 of reading ±1 pe ±0.3 m/s ±1 of reading ±0.1m/s ±0.2 of reading ±1 pe Ø 70 mm vane probe air velocity temperature airflow m/s fpm km/h °c °f m 3 /h cfm l/s m 3 /s m/s fpm km/h m 3 /h cfm l/s m 3 /s °c °f m/s fpm km/h mph m 3 /h cfm l/s m 3 /s m/s fpm km/h mph m 3 /h cfm l/s m 3 /s Ø 14 mm vane probe air velocity airflow temperature pitot tube air velocity airflow debimo blades air velocity airflow temperature co 2 co relative humidity air quality probes co co2 temperature hygrometry °c °f ppm ppm %rh rh g/kg kj/kg °c t d °f t d °c °f from from from from -20 to +80°c 0 to 5000 ppm 0 to 1,000 ppm 5 to 95 rh see related datasheet portable probes 0.1 °c 1 ppm 1 ppm 0.1 rh 0.1 rh 0.1 g/kg 0.1 °ctd 0.1 °c standard hygrometry probe std relative humidity absolute humidity enthalpy dew point ambient temperature ac cording to temperature and hygrometry measuring ranges from 3 to 98 %rh see related datasheet portable probes ±0.6 of reading ±0.5°c t d ±0.3 of reading ±0.25°c see related datasheet portable probes ±0.6 of reading ±0.5°c t d ±0.3 of reading ±0.25°c from -50 to +80°c t d from -20 to +80°c from 3 to 98 %rh high temperature hygrometry probe h.t relative humidity absolute humidity enthalpy dew point ambient temperature rh g/kg kj/kg °c t d °f t d °c °f according to temperature and hygrometry meas uring ranges 0.1 %rh 0.1 g/kg 0.1 °ctd 0.1 °c from -50 to +80°c t d from -40 to +180°c tachometry probe see datasheet portable probes multifunction probes see datasheet portable probes pt100 smart-plus probes see related datasheet all accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions or carried out with required compensation the accuracy is expressed either by a deviation in °c or by a percentage of the value concerned only the bigger value is considered.

[close]

p. 5

supplied with description supplied with ami 300 option pressure module from 0 to ±500 pa pressure module from 0 to ±2500 pa pressure module from 0 to ±10000 pa pressure module from 0 to ±500 mbar pressure module from 0 to ±2000 mbar current voltage module w cables thermocouple module climatic conditions module 2x1 m silicone tube Ø 4 x 7 mm stainless steel tips Ø 6 x 100 mm pitot tube Ø 6mm lg 300 mm pitot tube Ø 6mm lg 300 mm t pitot tube Ø 6mm lg 300 mm s optical tachometry probe etc adaptor reflective tape standard hotwire straight extension for hotwire telescopic gooseneck-shaped hotwire smart-plus Ø 14 mm vane probe telescopic smart-plus Ø 14 mm vane probe smart-plus Ø 70 mm vane probe wireless Ø 70 mm vane probe smart-plus Ø 100 mm vane probe wireless Ø 100 mm vane probe smart-plus standard hygrometry probe wireless standard hygrometry probe smart-plus high temperature hygrometry probe wireless high temperature hygrometry probe smart-plus pt100 temperature probe wirelesss pt100 temperature probe thermocouple k j and t probe co2 temperature probe co temperature probe co2 temperature hygrometry probe air velocity temperature hygrometry probe pc software usb cable memory calibration certificate transport case supplied w any choose of pressure modules accessories see related datasheet datalogger-10 datalogger-10 pc software for data recording and processing wired lpcf or wireless lpcr interface kpij 20 ­ 50 ­ 100 ­ 200 600 ammeter clamp with pvc cable lg 2m and jack connector rts telescopic extension length 1 m bent at 90° for measuring probe bnf hotwire cleaning spray see related datasheet silicone tube crystal flexible tube k 25 35 75 120 150 ads airflow cones see related datasheet ce 300 hands-free protective cover gst silicone heat conductive grease for temperature probes ads adaptor for power supply 120 vac see related datasheet debimo airflow blades of different sizes bn black ball Ø 150mm with junction for temperature probe Ø 4.5mm further dimensions available rd 300 straight extension for hotwire Ø 10 mm lg 300 mm jac set of 4 lr6 batteries cha 4 batteries charger warranty period instruments have 1-year guarantee for any manufacturing defect return to our service department p 21 5-7 50 -1212 f 215 -750-1 39 9 a 402 middletown b lvd s te 216 la ng horne pa 19 047 e instruments international www.e-inst.com

[close]

p. 6

aq 200 air quality monitor co2 co temp rh in one tool advantages interchangeable measurement up to 8,000 data memory points perform up to 6 measurements modules user-friendly joystick navigation large graphic display large ice blue backlight simultaneously instrument/pc communication wireless probes available connection interchangeables measurement modules 1 instrument more than 1 range and 1 parameter available wireless connection instrument pc instrument probe smart-plus system wireless or wired probes automatically recognized when connected to the instrument the instrument co2 temperature hygrometry humidity probe standard kit 19780 from 0 to 5,000 ppm /from -4°f to +176°f from 5 to 95 rh thermocouple temperature module ­ 4 channels n optio co temperature probe aq200 co kit 19781 from 0 to 1,000 ppm from -4°f to +176°f n optio climatic conditions module ­ hygro/temp air pressure n optio wired or wireless temperature probe n optio or

[close]

p. 7

functions technical features sensing elements air quality probe co2 ndir infrared sensor non dispersive infrared co electrochemical sensor temperature pt100 class a hygrometry capacitive hygrometry sensor climatic conditions module hygrometry capacitive hygrometry sensor temperature semiconductor temperature sensor air pressure capacitive sensor thermocouple probes type k j and t class 1 pt100 smart-plus probes pt100 class 1/3 din on the top 2 secured mini-din connectors for smart-plus probes left side 1 usb port for eig cable only 1 power supply plug air quality climatic conditions module selection of units minimum maximum values and hold function storage air quality probes co2 temperature hygrometry standard kit ­ 19780 ­ aq200 p co temperature optional ­ 19781 aq200co audible alarm 2 setpoints selection of units minimum maximum values and hold function storage aq200 connection thermometer thermocouple module dynamic delta t audible alarm lower and upper setpoints selection of units minimum maximum values and hold function 4-channel storage of thermocouple k j and t interchangeable measurement modules thermocouple module connection 4 inputs for compensated miniature plug of thermocouple type k j or t class 1 as per iec 584-3 norm display temperature probes dynamic delta t audible alarm lower and upper setpoints selection of units minimum maximum values and hold function storage current voltage module connection 2 stereo jacks graphic display 128x128 pixels dim 50 x 54 mm blue backlight display of 6 measurements including 4 simultaneously housing keypad abs shock-proof ip54 current voltage module adjustable ranges minimum maximum values and hold function storage metal-coated 5 keys 1 joystick conformity electromagnetical compatibility nf en 61326-1 norm datalogger-10 multi-parameters recording manual and automatic storage memory up to 8,000 measurement points or power supply 4-aa alkaline batteries 1.5v lr6 included operating environment neutral gas 50 datasets user-friendly with printing of customized report management of instruments pool follow-up of calibration periods intervention planning wired or wireless interface operating temperature from 0 to +122°f storage temperature from -4 to +176°f auto shut-off adjustable from 0 to 120 min weight 12 oz languages english french dutch german italian spanish portuguese swedish norwegian finn danish

[close]

p. 8

dimensions mm top view front view side view 57.4 specifications measuring units current voltage v ma from 0 to 2.5 v from 0 to 10 v from 0 to 4/20 ma ±2mv ±10mv ±0.01ma measuring range accuracy resolution s 0.001 v 0.01 v 0.01 ma thermocouple see related datasheet °f °c k from -328 to 2372°f j from -148 to 1382°f t from -328 to 752°f ±1.1°f or ±0.4 reading ±0.8°c or ±0.4 reading ±0.5°f or ±0.4 reading 0.1 °f 0.1 °f 0.1 °f climatic conditions hygro %rh from 5 to 95%rh accuracy repeatability linearity hysteresis ±1.8%rh from 15°c to 25°c factory calibration uncertainty ±0.88 %rh temperature dependence ±0.04 x t-20 %rh if t<15°c or t>25°c 0.1 rh temp air pressure °c °f hpa from -4 to +176°f from 800 to 1,100 hpa ±0.4 of reading ±0.3°f ±3 hpa 0.1 °f 1 hpa co temperature optional ­ aq200co ­ part 19781 temp co °c °f ppm from -4 to +176°f from 0 to 100 ppm from 101 to 1,000 ppm ±0.4 of reading ±0.3°f ±5ppm ±3 of reading ±5ppm 0.1 °f 1 ppm co2 temperature optional temp co 2 °c °f ppm from -4 to +176°f from 0 to 5,000 ppm ±0.4 of reading ±0.3°f ±3 of reading ±50ppm 0.1 °f 1 ppm co2 temperature hygrometry standard kit ­ aq200p ­ part 19780 temp co 2 hygro °c °f ppm %rh from -4 to +176°f from 0 to 5,000 ppm from 5 to 95%rh ±0.4 of reading ±0.3°f ±3 of reading ±50ppm see climatic conditions module 0.1 °f 1 ppm 0.1 rh pt100 smart-plus or wireless probes see related datasheet °c °f from -58 to 482°f accoding to model ±0.3 of reading ±0.25°f accoding to model 0.01 °f all accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions or carried out with required compensation as per nfx 15-113 and the charter 2000/2001 hygrometers gal guaranteed accuracy limit which has been calculated with a coverage factor value of 2 is ±2.88%rh between 18 and 28°c on the measuring range from 5 to 95%rh sensor drift is less than 1%rh/year the accuracy is expressed either by a deviation in °c or by a percentage of the value concerned only the bigger value is considered.

[close]

p. 9

working principle ndir non dispersive infrared absorbance a gas absorbs light at a specific wavelength some of the intensity emitted by the infrared source is absorbed by the gas sample the amount of light read by the ir sensor is inversely proportional to co2 concentration light intensity light intensity infrared sensor infrared light gas sample auxiliary electrode air electrochemical sensor electrochemical cell consists of a container 2 electrodes connexion wires and an electrolyte carbon monoxide is oxidised at one electrode to co 2 whilst oxygen is consumed at the other electrode the current produced is proportional to co concentration gas working electrode e electrolyte oh hco3 co32 a supplied with supplied with description current voltage thermocouple temperature module climatic condition module co2 temperature probe co temperature probe co2 temperature hygrometry probe thermocouple k j and t probe smart-plus pt100 probe wireless pt100 probe 8 rechargeable batteries with charger current voltage cable calibration certificate hard aluminum transport case large choice of temperature probes see related datasheet ambient contact penetration food industry penetration general use option aq 200 accessories see related datasheet datalogger-10 datalogger-10 datalogger-10 pc software for data recording and processing wired lpcf or wireless lpcr interface ce 200 hands-free protective cover kpij 20 ­ 50 ­ 100 ­ 200 600 kpij 20 ­ 50 ­ 100 ­ 200 600 ammeter clamp with pvc cable lg 2m and jack connector gst silicone heat conductive grease for temperature probes rts telescopic extension length 1 m bent at 90° for measuring probe ads adaptor for power supply 120 v jac set of 4 lr6 batteries cha 4 batteries charger ctc-p input current or voltage input pvc cable lg 2 m and jack connector warranty period instruments have 1-year guarantee for any manufacturing defect return to our service department for repair/evaluation/calibration p 215-7 50 -1212 f 215 -75 0-139 9 a 402 middle town blvd s te 2 16 lang horne pa 19 047 e instruments international www.e-inst.com

[close]

p. 10

air quality ask about calibration certificate aq 100 functions co2 measurement and ambient temperature selection of units minimum and maximum values hold function adjustable automatic shut-off adjustable backlight technical features measuring element co2 infrared sensor non dispersive infrared sensor ndir ambient temperature pt100 class a 2 lines lcd technology sizes 50 x 34.9 mm 1 line of 5 digits with 7 segments value 1 line of 5 digits with 16 segments unit shock-proof made of abs ip54 protection metal-coated with 5 keys retractable length 18 inch 450 mm up to 8 ft 2.4 m when released electromagnetical compatibility nf en 61326-1 guideline 1 alkaline battery 9v 6lr61 included from 0 to 122°f from -4 to +176°f adjustable from 0 to 120 min 6.7 oz english french display housing keypad cable conformity power supply operating temperature storage temperature auto shut-off weight languages aq100 ­ co2 temperature probe ­ fixed probe 12 6.3 .78

[close]

p. 11

specifications measuring units co2 measuring ranges accuracy resolutions ppm ambient temperature from 0 to 5000 ppm ±3 of reading ±50 ppm 1 ppm °f °c from -4 to +176°f ±0.4 of reading ±0.3°f 0.1°f/c all accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions or carried out with required compensation the accuracy is expressed either by a deviation in ppm or by a percentage of the value concerned only the bigger value is considered working principle ndir non dispersive infrared absorbance a gas absorbs light at a specific wavelength some of the intensity emitted by the infrared source is absorbed by the gas sample the amount of light read by the ir sensor is inversely proportional to co 2 concentration supplied with description hard abs case soft vinyl case aq 100 included light intensity light intensity infrared sensor optional 18.3 8.4 accessories see related datasheet infrared light gas sample dimensions mm protective cover with magnet and holding system top view 70.6 telescopic extension for probe 1m long and bent at 90° front view 50 side view warranty period instruments have 1-year guarantee for any manufacturing defect return to our service department p 21 5-7 50 -1212 f 215 -750-1 39 9 a 402 middletown b lvd s te 216 la ng horne pa 19 047 e instruments international www.e-inst.com ftang ­ aq100 ­ 10/08 c ­ we reserve the rigth to modify the characteristics of our products without notice ce 100 rts

[close]

p. 12

e instruments international is a manufacturer provider of a complete range of innovative instrumentation solutions including portable combustion gas analyzers gas leak detectors iaq monitors which we export to over 50 countries worldwide for more information about our products please contact us at 215-750-1212 or visit our website at www.e-inst.com

[close]

Comments