DPP Single Phase

 

Embed or link this publication

Description

Single Phase Digital ProcessPower UPS System from AMETEK Solidstate Controls

Popular Pages


p. 1



[close]

p. 2



[close]

p. 3



[close]

p. 4



[close]

p. 5

0.8 output power factor 120vdc 60 lead calcium battery cells rated output power kw kva 5 4 7.5 6 10 8 15 12 20 16 30 24 40 32 50 40 efficiency ac-dc dc-ac 92 87 92 87 92 87 92 87 93 87 93 87 93 87 93 87 ac input/freq ac amps per phase 480/60 280/60 380/50 11 25 14 16 37 20 21 48 26 31 70 39 40 92 50 59 137 75 78 181 99 99 228 125 ac input/freq ac amps per phase 480/60 280/60 380/50 58 134 73 76 176 97 96 220 121 119 276 151 153 353 193 dc current 1.75vpc 44 66 88 131 175 263 350 438 dc current 1.75vpc 128 171 214 257 342 ac output amps per phase 120 220 240 42 23 21 63 34 31 83 46 42 125 68 63 167 91 83 250 136 125 333 182 167 417 227 208 model dpp005 dpp007 dpp010 dpp015 dpp020 dpp030 dpp040 dpp050 ups cabinet style gtd1x gtd1x gtd1x gtd1x gtd1x gtd2x gtd2x gtd2x ups cabinet style gtd1x gtd2x gtd2x gtd3x gtd3x weight lbs 765 930 1100 1300 1500 1950 2050 2150 kg 347 422 499 590 680 885 930 975 heat loss watts 998 1996 1995 2993 3775 5663 7550 9438 240vdc 120 lead calcium battery cells rated output power kw kva 30 24 40 32 50 40 60 48 80 64 efficiency ac-dc dc-ac 93 89 94 89 94 89 94 89 94 89 ac output amps per phase 120 220 240 250 136 125 333 182 167 417 227 208 500 273 250 667 364 333 weight lbs 1950 2050 2150 2550 3400 kg 885 930 975 1157 1542 heat loss watts 4996 6250 7813 9375 12500 model dpp030 dpp040 dpp050 dpp060 dpp080 1.0 output power factor 120vdc 60 lead calcium battery cells rated output power kva kw 5 4 7.5 6 10 8 15 12 20 16 30 24 40 32 efficiency ac-dc dc-ac 92 87 92 87 92 87 92 87 93 87 93 87 93 87 ac input/freq ac amps per phase 480/60 280/60 380/50 15 35 20 20 47 26 30 70 39 40 93 51 60 139 76 81 187 102 99 228 125 ac input/freq ac amps per phase 480/60 280/60 380/50 77 178 98 96 220 121 119 276 151 153 353 193 dc current 1.75vpc 55 82 109 164 219 328 438 dc current 1.75vpc 161 214 268 321 ac output amps per phase 120 220 240 42 23 21 63 34 31 83 45 42 125 68 63 167 91 83 250 136 125 333 182 167 model dpp005 dpp007 dpp010 dpp015 dpp020 dpp030 dpp040 ups cabinet style gtd1x gtd1x gtd1x gtd1x gtd2x gtd2x gtd2x ups cabinet style gtd2x gtd2x gtd3x gtd3x weight lbs 940 1105 1300 1500 1950 2050 2150 kg 426 501 590 680 885 930 975 heat loss watts 1247 1770 2494 3539 4719 7078 9438 240vdc 120 lead calcium battery cells rated output power kw kva 30 24 40 32 50 40 60 48 efficiency ac-dc dc-ac 93 89 94 89 94 89 94 89 ac output amps per phase 120 220 240 250 136 125 333 182 167 417 227 208 500 273 250 weight lbs 2050 2150 2550 3400 kg 930 975 1157 1542 heat loss watts 5859 7813 9766 11719 model dpp030 dpp040 dpp050 dpp060 circuit breakers are sized at a minimum of 125 of rated current model coding gg freq code 50 ­ 50 60 ­ 60 dd ac input volts code 480 ­ 48 600 ­ 60 380 ­ 38 ee dc bus volts code 120 ­ 12 240 ­ 24 ff ac output volts code 120 ­ 12 220 ­ 22 240 ­ 24 hh output p.f code 0.8 ­ k 1.0 ­ w i charger design code 6-pulse ­ s 12-pulse ­ t j config code code cascaded ­ c float ­ f a complete model number includes the ac input voltage dc bus link voltage ac output voltage system frequency output power factor and ups configuration to build a model number use the code in the matrix shown above following the example format dpp010-dd-ee-ff-ggh-i-j where dd=ac input voltage ee=dc bus voltage ff=ac output voltage gg=system frequency h=output power factor k for 0.8 `w for 1.0 i=6s or 12t pulse charger design j=ups configuration f for float `c for cascaded redundant for example a 20 kva with 480 volt input 120 vdc bus voltage 120 volt output 60 hz 0.8 output power factor 6=pulse charger float system would have the following model number dpp020-48-12-12-60-k-s-f for custom systems and for units which do not have a configurable model number insert a `c in the model number as follows dpp020c sizes which are subject to change certain optional features and/or combinations may require larger cabinets contact factory h 79 79 79 79 xxxxxw 32 54 86 108 xxxxxd 36 36 36 36 inches cabinet-dimensions mm hxwx 2007 x 813 x 2007 x 1372 x 2007 x 2184 x 2007 x 2743 x d 914 914 914 914

[close]

p. 6



[close]

Comments

no comments yet