p. 1
digital gauge dg10b dg25b high accuracy rugged gauges suitable for installation on machines ·magnetic principle ·excellent resistance to workshop conditions bp/bs ip64 resistant to oil water dust vibrations and shocks ·accuracy ± 1 µm ·resolution 0.5 µm ·measuring range 10 mm 0.39 and 25 mm 0.98 ·high measuring force bp/bs ·low measuring force bn/bl ·easy installation ·a variety of accessories available see accessories for gauges dg10bs dg25bs/dg25bl dg10bp/dg10bn dg25bp/dg25bn specifications model measuring range resolution accuracy at 20 °c 68 °f upward measuring force lateral downward protective design grade sealing oil water dust mounting stem diameter operating temperature storage temperature cable length feeler mass excl cable unit option dg10bp dg10bs 10 mm 0.39 dg10bn dg25bp 0.5 µm ± 1 µm dg25bs dg25bn dg25bl 25 mm 0.98 all directions 4.9 n or less equivalent to ip64 oil sealing o-rings y-gaskets equivalent to ip64 oil sealing o-rings y-gaskets 0 ø 20 -0.013 mm 0 °c to 50 °c 32 °f to 122 °f -20 °c to 60 °c -4 °f to 140 °f 5 m/16.4 feeler tipped with 2.5 mm dia carbide ball with m2.5 x 0.45 screw on fitting end dz122 0.1 kg/0.22 lbs 0.2 kg/0.44 lbs none air lifter dz-161 mountable none air lifter dz-161 mountable 0.3 ± 0.25 n 0.6 ± 0.3 n 0.8 ± 0.35 n all directions 4.9 n or less 0.4 ± 0.3 n 0.7 ± 0.35 n 1 ± 0.4 n dimensions dg10bs 102.3/4.02 12.5/0.49 stem 25/0.98 26.3/1.03 ø20 +0.02 -0.07 /ø0.78 +0.0007 -0.0027 dg10bp/dg10bn ø20 +0 -0.013 /ø0.78 +0 -0.0005 79/3.11 52.8/2.07 11.5/0.45 11.8/0.46 ø6/ø0.23 37/1.45 49.5/1.94 ø22/ø0.86 21.3/0.83 69.5/2.73 ø6/ø0.23 21.3/0.83 12/0.47 11.50.45 98.5/3.87 121.8/4.79 20/0.78 dg25bs/dg25bl ø20 +0 -0.013 /ø0.78 +0 -0.0005 stem 20/0.78 12.3/0.48 dg25bp/dg25bn ø20 +0 -0.013 25/0.98 ø6/ø0.23 12/0.47 26.5/1.04 33.8/1.33 95.3/3.75 26.3/1.03 12.5/0.49 ø6/ø0.23 37/1.45 49.5/1.94 69.5/2.73 33.8/1.33 12/0.47 26.5/1.04 141/5.55 179.3/7.05 20/0.78 ø20 +0.02 -0.07 /ø0.78 +0.0007 -0.0027 ø20 +0 -0.013 /ø0.78 +0 -0.0005 stem ø22/ø0.86 12.3/0.48 20/0.78 stem 121.5/4.78 ø20 +0.02 -0.07 /ø0.78 +0.0007 -0.0027 159.5/6.27 unit mm/inch gauges
[close]
p. 2
digital gauge dg50b dg100b dg155b dg205b gauges high accuracy rugged gauges suitable for installation on machines ·magnetic principle ·excellent resistance to workshop conditions bp ip64 resistant to oil water dust vibrations and shocks ·accuracy ± 1 µm dg50bp/50bn ± 2 µm dg100bp/100bn ± 2.5 µm dg155bp ± 3 µm dg205bp resolution 0.5 µm · ·measuring range 50 mm 1.96 100 mm 3.93 155 mm 6.10 and 205 mm 8.07 ·high measuring force dg50bp/100bp ·low measuring force dg50bn/100bn ·magnet feeler dg155bp/205bp ·easy installation ·a variety of accessories available see accessories for gauges dg50bp/dg50bn dg100bp/dg100bn dg155bp/dg205bp the photo shows dg155bp specifications model measuring range resolution accuracy at 20 °c /68 °f upward measuring force lateral downward protective design grade sealing oil water dust mounting stem diameter operating temperature storage temperature cable length feeler magnetic feeler mass excl cable unit option dg50bp dg50bn dg100bp dg100bn dg155bp 155 mm 6.10 ± 2.5 µm dg205bp 205 mm 8.07 ± 3 µm 50 mm 1.96 ± 1 µm 100 mm 3.93 0.5 µm ± 2 µm all directions all directions 0.9 ± 0.4 n 1.8 ± 0.65 n 6.2 n or less 9.3 n or less 1.3 ± 0.5 n 2.7 ± 0.55 n equivalent to ip64 equivalent to ip64 oil sealing,o-rings,y-gaskets oil sealing,o-rings,y-gaskets 0 ø 20 -0.013 mm 0 °c to 50 °c /32 °f to 122 °f -20 °c to 60 °c -4 °f to 140 °f 5m/16.4 carbide ball tipped feeler dz122 carbide ball tipped feeler dz121 0.35 kg 0.77 lbs air lifter dz-161 none mountable 0.6 kg 1.32 lbs air lifter dz-161 none mountable equivalent to ip64 oil sealing o-rings y-gaskets 0 ø 32 -0.05 mm dz181 carbide ball tipped feeler attraction force 10n lateral slippage force:2.7n 1.1 kg 2.43 lbs 1.3 kg 2.87 lbs none dimensions ø20 +0 -0.013 /ø0.78 +0 -0.0005 ø6/ø0.23 dg50bp/bn 12/0.47 44/1.73 223/8.77 286/11.25 ø8/ø0.31 ø20 +0 -0.013 /ø0.78 +0 -0.0005 34/1.33 dg100bp/bn 12/0.47 2.5/0.09 38.5/1.51 2/0.07 ø25 +0 -0.1 /ø0.98+0 -0.004 329.5/12.97 443.5/17.46 ø32 +0 -0.05 /ø1.25 +0 -0.0019 ø32 +0 -0.05 /ø1.25 +0 -0.0019 ø20 +0.02 0.1 /ø0.78 +0.0007 -0.003 34/1.33 dg155bp dg205bp m5 x 8 ø8/ø0.31 9/0.35 28/1.10 dg155p=407/16.02 dg155p=571/22.48 dg205p=507/19.96 34/1.33 dg205p=721/28.38 unit mm/inch
[close]
p. 3
digital gauge for automatic inspection/measurement in production line dg-m/e series model dg805 blm/ble flm/fle ·a/b quadrature signal output with differential line driver ·highly reliable magnescale principle ·two types of power supply voltage 5v dc and 12 to 24v dc ·compact design outside diameter ø 8 mm dg805 810 ® and a line up to cover a wide measuring range 5 mm to 205 mm specifications gauges dg810 bm/be fm/fe dg810 dg10 dg10 dg10 dg25 dg25 dg25 dg25 blm/ble bpm/bpe bsm/bse bnm/bne bpm/bpe bsm/bse bnm/bne blm/ble flm/fle measuring length l mm inch 5.2mm resolution accuracy at 20 °c /68 °f 0.4 ± 0.3n upward 0.35 ± 0.25n measuring force 0.5 ± 0.3n lateral 0.40 ± 0.25n at 20 °c /68 °f downward 0.45 ± 0.25n 0.6 ± 0.3n protection grade ø 8 0 -0.009 mm ø 0.31 0 -0.0004 mounting stem diameter l type ø 9.5 0 0.009 mm ø 0.37 0 -0.0004 n/a lift lever dz801option dz801option n/a air lifter note 1 note 1 cable length operating temperature storage temperature feeler ø 3mm carbide ball with m2.5 x 0.45 feeler screw on fitting end dz123 mass excl cable unit 20 g 40 g 10 mm 25 mm 0.5 1 2 5 10 µm switch-selectable ±1 µm 0.3 ± 0.25n all directions all directions 0.6 ± 0.3n 4.9n or less 4.9n or less 0.8 ± 0.35n ip64 equivalent ip64 equivalent ø 200 -0.013 mm ø 0.79 0 -0.0005 n/a dz161option n/a 0.4 ± 0.3n 0.7 ± 0.35n 1 ± 0.4n dz161option dz174-010 option note 1 5 m 16.4 0 to 50 °c 32 °f to 122 °f -20 to 60 °c 4 °f to 140 °f dz174-025 option note 1 feeler ø 2.5 mm carbide ball with m2.5 x 0.45 screw on fitting end dz122 100 g 200 g specifications gauges model dg50 bpm/bpe dg50 bnm/bne dg100 bpm/bpe dg100 bnm/bne dg110 bm/be dg155 bpm/bpe 155 mm ± 2.5 µm dg205 bpm/bpe 205 mm ± 3 µm measuring length l mm inch 50 mm resolution accuracy at 20 °c /68 °f ± 1 µm upward measuring force all directions 0.9 lateral 6.2n or less at 20 °c /68 °f 1.3 downward ip64 equivalent protection grade mounting stem diameter lift lever air lifter cable length operating temperature storage temperature feeler magnetic feeler mass excl cable unit 100 mm 110 mm 0.5 1 2 5 10 µm switch-selectable ± 2 µm all directions ± 0.4n 1.8 ± 0.65n 9.3n or less ± 0.5n 2.7 ± 0.55n 1.55 ± 0.15n note2 ip64 equivalent ø 20 0 0.03 mm ø 20 0 0.013 mm ø 0.79 0 -0.0005 ø 0.79 0 0.001 n/a dz161 option n/a dz161 option dz161 included dz174-050 option note 1 n/a 5m 16.4 2 m 6.56 0 to 50 °c 32 °f to 122 °f -20 to 60 °c -4 °f to 140 °f feeler tipped with ø 2.5 mm carbide ball with feeler tipped with ø 2.5 mm carbide ball with m2.5 x 0.45 screw on fitting end dz122 m2.5 x 0.45 screw on fitting end dz121 n/a 350 g 600 g 1150 g resistance against slip 2.7n do not have an internal spring ip64 equivalent ø 32 0 -0.05 mm ø 1.26 0 -0.002 dz161 option n/a 5 m 16.4 dz181 included attraction force 10n 1100 g 1300 g note1 tubing for compressed air device can be attached note2 the measurement force values given apply when dz-581 measuring force balancer is not used by using a measuring force balancer option it is possible to reduce the measuring force to a minimum of 0.3n the measuring force will be constant regardless of spindle position specifications interpolator model power supply voltage power consumption output interface output signal resolution maximum response speed minimum phase difference dg-m dg-e alarm output connector dimensions operating temperature storage temperature mass excl cable and gauge part dc 5 v ± 5 corresspond to dc 11 v to 28 v corresspond remote sensing function to remote sensing function 300 ma maximum 150 ma maximum based on eia-422 line driver:am 26c31 or equivalent a/b quadrature signal 0.5,1,2,5,10 µm 0.000025 0.0005 0.0001 0.00025 0.0005 selectable 1 m/s 200 ns the output phase difference varies with the measuring speed a/b quadrature output of this probe turns to high impedance for 10 to 20 ms when excessive speed or cable disconnection alarm occurs if the cause is removed the alarm signal is automatically reset mdr10214-52a2jl 3m 125 x 28 x 28 mm not including projecting parts 0 to 40 32 °f to 104 °f -20 to 60 -4 °f to 140 °f 150 g gauges
[close]
p. 4
digital gauge dg-m/e series dimensions gauge 114/4.48 cable length 5m/16.4 interpolator 125/4.92 117.5/4.62 38/1.49 2-m4 depth4/0.15 26/1.02 100/3.93 9/0.35 unit mm/inch 0 ø8 -0.009 0 /ø0.31-0.0003 gauges 30/1.18 28/1.10 18/0.70 stem
[close]