p. 1
-1 eddy c urrent eddy current distance and displacement transducer s eries tx · measurement ranges 0,5 10 mm · one or dual-channel device · outputs 10v 5v ±5v 04 20 ma can · linearity ±0,25 of fs · high frequency measurements 35 khz · operating temperature -35 185°c · unaffected of non-metallic media in the measurement room e.g water oils fouling synthetics · distance measurement on static and rotating objects · measurement of unbalance and vibration · contactless quality check in automation 22.05.09
[close]
p. 2
-2introduction waycon positionsmesstechnik gmbh is a manufacturer of high quality eddy current displacement transducer for industrial use these devices measure contactless and high-vibrantly distances vibration and rotation of metallic conducting objects irrespective non-metallic media in the measurement room e.g oil the fundamental measurement principle is based on the fact that the coil in the probe produces an alternating magnetic field the streamlines of the field leave the probe pass the object and close together thereby the alternating magnetic field induces eddy currents in the electroconductive object which causes energetic losses this eddy current loss in the object rises with less distance of the probe at the front-end of the sensor coil this extraction of eddy current loss is evaluated via the changing of the complex input impedance the microcontroller used by waycon provides to handle only certain spectral components within a strictly limited bandwidth interferences from other spectral ranges are extracted the analoge output signal is conditioned and issued via the microcontroller overview the eddy current basic module can be constructed in one or dual-channel way it is possible to use different ranges probes in connection with a 2-channel basic module · dsp on board one or dual-channel construction low power-architekture 1,9 v core can on board · possibilities of software cascading multiplexing master/slave function adaptation of material form factor cable length compensation customized linearisation data storage can-bus-transfer teach-in min-max peak threshold alarm filter · probes enlarged measurement ranges pressure resistant construction special casing/integration in customers periphery applications · axial and radial wave displacement · unbalance vibration and shock · measurement of roundness ovality · bending and deformation · measurement of bearing clearance and detection of bearing erosion · measurement of split lube at oi pressurel · detection of tooth flanks · detection of tappets and tappet travel · detection of slots and measurement of depth of slots · press gaps · carriage forming form checking · measurement of thickness of foils and non-conductive media
[close]
p. 3
-3technical data typ m easurem ent ranges fs housing dim ens ions resolution linearity filter corner frequency dynam ics output tem perature range probe tem p range electronics supply m ax power consumption short circuit res is tance resist reverse polarity case m aterial probe sensor cable protection clas s probe prot class electronics 99,0 confidence interval m idrange t05 0 0,5 m m ø 5 mm t2 0 2 m m ø 8 mm t3 0 3 mm ø 12 m m t4 0 4 m m ø 14 m m t5 0 5 m m ø 18 mm t10 0 10 m m ø 30 m m 10 hz 0,007 1 khz 0,018 35 khz 0,1 ±0,25 v mb 10 hz 100 hz 1 khz 10 khz 35 khz 3 db output rate 120 khz 1-kanal 70khz 2-kanal 0 10 v 0 5 v ±5 v 0 20 m a 4 20 m a -35 185°c -10 70°c 9 36 vdc wide input 190 m a 24v 300 m a 12v 390 m a 9v yes yes stainless s teel 1.4305 probe head peek p#olyetheretherketon ptfe-koax length 3m /6m and cus tom ized length ip67/ip68 ip40 connection diagramm digital in out/can d-sub 9-pin male pin 1 2 3 4 5 6 7 8 9 nam e ext opto out1 can l can gnd ext in 1 ext in 2 in gnd can h ext opto out2 can gnd des cription digital output i/o 1 can low signal can ground digital input i/o 1 digital input i/o 2 ground i/o can high signal digital output i/o 2 can ground note all in and outputs are galvanically separated via optoelectronic coupler supply m12 2 white n.c 3 blue gnd 1 brown v 9 36 vdc 4 black n.c technical drawings electronics d-sub 9-pin male supply m12 connector usb ns or 2 2 ou tp ut 1 ou tp ut se se ns or 1
[close]
p. 4
-4technical data probes cable axial t04-s-ka k bl o 1 ae ,7 t04 not available yet t04-g-ka o 4 o 3 ,1 e s hd 4 1 intic in 7 kbl o 1 ae ,7 35 1 7 2 0 t05-s-ka o 4 o 5 3 5 2 0 t05-g-ka o 4 e s hd 4 1 intic in 7 s 4 w s 4 w o 67 o 8 o 6 ,7 e s hd 4 1 intic in 7 s 6 w m 8 x1 t2-s-ka kbl o 2 ae ,7 t2-g-ka s 6 w 45 1 9 2 4 e s hd 4 1 intic in 7 s 1 w0 o 1 2 4 ,5 2 4 k eo 2 ab l ,7 k bl o 2 ae ,7 k eo 2 ab l ,7 m 1 x1 2 t3-s-ka o 1,5 0 k eo 2 ab l ,7 t3-g-ka o 1,5 0 s 1 w0 5 ,5 1 9 55 2 6 k eo 2 ab l ,7 2 6 m 1 x1 4 t4-s-ka o 1,3 2 o 1 4 e s hd 4 1 intic in 7 s 1 w2 t4-g-ka o 1,3 2 s 1 w2 6 2 0 6 2 7 e s hd 4 1 intic in 7 s 1 w6 kbl o 2 ae ,7 2 7 m 1 x1 8 t5-s-ka o 1,7 5 o 1 8 t5-g-ka o 1,7 5 s 1 w6 7 7 2 1 2 8 2 8 note drawing of t10 on request kbl o 2 ae ,7 35 1 7 2 2 3 ,5 2 2 k bl o 1 ae ,7 m 5 x0 ,5 k eo 1 ab l ,7 m 4 x0 5 ,3 o 3 ,1
[close]
p. 5
-5technical data probes cable radial t2-s-kr 45 1 5 o 8 2 4 t2-g-kr 2 4 4 ,5 o 6 ,7 o 6 ,7 s 6 wkblo 27 ae 2 6 m 8 x1 s 6 w k bl o 2 ae ,7 e s hd 4 1 intic in 7 t3-s-kr 5 ,5 o 1,5 0 t3-g-kr 55 o 1 ,5 0 1 7 2 6 m 1 x1 2 o 1 2 s 1 w0 e s hd 4 1 intic in 7 k bl o 2 ae ,7 s 1 w0 k bl o 2 ae ,7 t4-s-kr 6 o 1 23 2 7 1 8 t4-g-kr 6 2 7 m 1 x1 4 s 1 w2 e s hd 4 1 intic in 7 k bl o 2 ae ,7 o 1,3 2 o 1 4 s 1 w2 kbl o 2 ae ,7 t5-s-kr 7 o 1 57 2 8 1 9 t5-g-kr 7 o 1 57 2 8 m 1 x1 8 o 1 8 s 1 w6 e s hd 4 1 intic in 7 kblo 27 ae s 1 w6 k bl o 2 ae ,7 note drawing of t10 on request
[close]
p. 6
-6order code t measurement ranges 0,5/2/3/4/5/10 mm options water protection ip67 pressure sealed up to 15 bar probe e.g 2 ip67 p15 case shaft thread flange s g f cable output radial axial customized version available on request kr ka order code eddy current basic module tx number of channels 1 channels 2 channels 1 2 d in options tft display touch screen inverted output supply 24 v wide input 9 36 vdc 12 24 10v 5v ±5v 420a 020a analogue output channel 0 10v 0 5v -5 5v 4 20ma 0 20ma resolution 16 bit ad/da 16 approximately available in 9/09 these data can be changed without any advance notice waycon positionsmesstechnik gmbh e-mail info@waycon.de internet www.waycon.de head office mehlbeerenstr 4 82024 taufkirchen tel +49 089 67 97 13-0 fax +49 089 67 97 13-250 office köln auf der pehle 1 50321 brühl tel +49 02232 56 79 44 fax +49 02232 56 79 45
[close]
p. 7
-7accessories supply cable with m12 mating connector k4p2m-s-m12 k4p5m-s-m12 k4p10m-s-m12 2 m straight connector 5 m straight connector 10 m straight connector bnc cable for output signal iec 61010 xlam-446/sc high flexible length 1,6 m k4p2m-sw-m12 2 m angular connector k4p5m-sw-m12 5 m angular connector k4p10m-sw-m12 10 m angular connector diese daten können jederzeit ohne vorankündigung geändert werden waycon positionsmesstechnik gmbh e-mail info@waycon.de internet www.waycon.de head office mehlbeerenstr 4 82024 taufkirchen tel +49 089 67 97 13-0 fax +49 089 67 97 13-250 office köln auf der pehle 1 50321 brühl tel +49 02232 56 79 44 fax +49 02232 56 79 45
[close]