Waycon Drawwire Sensor SX135 Long Range

 

Embed or link this publication

Description

Draw wire sensors are suitable for measuring linear and non-linear motions. The compact style allows flexible and easy installation. Due to the small size, precise measurement is possible even in difficult applications.

Popular Pages


p. 1

drawwire sensor sx135 long range key-features contents introduction ­ applications options sx135 up to 42,5 m technical drawings mounting easy-clamp analogue output digital output absolute output accessories installation ­ warning notices order code 10.06.10 2 3 4 5 9 10 11 12 13 14 15 ranges 8000 42500 mm analogue ­ digital ­ absolute bus linearity up to 0,02 protection class up to ip67 high dynamics off-shore sensors high emc-grade customised versions available

[close]

p. 2

-2 introduction waycon positionsmesstechnik gmbh is a manufacturer of high quality draw wire position transducers for industrial use due to its small overall size its short assembly time and its possible customisation the sx sensor technology is a cost-effective and flexible solution for a wide range of industrial applications the dynamics of the draw wire transducer allows a high motion speed and acceleration of the measuring target its rugged design and high quality makes applications in harsh industrial environments possible sensors specifically designed for off-shore use receive a hartcoat surface which makes them resistant to e g sea water special instruments are available with mounting service of encoder on site as well as customised versions of housing sensor principle a constant spring force coils the measuring rope accurately single-layered on an ultralight rope capstan so that its linear motion is converted into rotation the sensor element encoder provides the output signal required measuring rope tension spring rope capstan rotating shaft sensor element sx50 electronics outline easy rope fixation with rope clip diamond-polished ceramic bushing measuring rope stainless steel gearwheels made of nitride hardened steel and high performance plastics best linearity m12 connector or cable output guided rope outlet provides precise winding of the rope on the capstan waterproof housing ip65 and ip67 dynamic spring drive for max track speed easy-clamp-mechanism for fast encoder assembly titanium and hard anodised aluminium housing fast and easy mounting with t-slot nuts or angle clamp brackets applications · · · · · lifting tables and platforms positioning of fork-lifts level control system portal frames and gantry cranes lifting and rescue technology · · · · · hydraulic cylinder property management linear guides x-y-axis positioning pipe displacement

[close]

p. 3

-3 options co135 by the use of a special technology all components of the housing and the inner mechanics become hartcoat ® coated this coating is a hartanodic oxidation that protects the sensor from corrosion by aggressive media e g sea water with a hard ceramics-like layer the sensor can thus be used off-shore in the analogue signal of the sensor is increasing by extracting the rope standard option in inverts the signal i e the signal of the sensor declines by extracting the rope output signal 10v/20ma inverted 0v/4ma 0 standard retract range fs extract l05 l02 improved linearity on 0,05 of measuring range resolution repeatability and sensibility remain unchanged improved linearity on 0,02 of measuring range resolution repeatability and sensibility remain unchanged this option is only available for incremental sensors ip67 use option ip67 if sensor is fully immersed in water temporarily note that with this option there may occur a light hysteresis in the output signal due to the special sealing the max acceleration is reduced to 60 of the specified value m4 rope fixation optional rope fixation with screw thread m4 ideal for attachment to through holes or thread holes m4 rope clip with drill protection standard optional m4 rope fixation

[close]

p. 4

-4 series sx135 output analogue potentiometer 0 10 v 4 20 ma page 10 digital output digital-absolute bus systems a/b-pulse 90° phase-delayed page 11-12 incremental encoder optical code disc connector or cable output ip65 optional ip67 max 90 relative not condensating approx 4200 g aluminium titanium-grey and hard anodised sensor element connection protection class humidity weight housing hybrid potentiometer m12-connector or cable output ip65 optional ip67 max 90 relative not condensating approx 4200 g aluminium titanium-grey and hard anodised technical data ­ analogue output ranges [m linearity linearity optional technical data ­ digital output ranges [mm linearity linearity optional available resolution range 8 m [pulses mm z-pulse-distance range 8 m [mm z-pulse-distance range 10 ­ 42,5 m [mm other measurement ranges on request mechanical data rope tension range [m 8 10 12 15 20 25 30 40 42,5 fmin [n 7,2 8,7 7,0 7,3 7,0 fmax [n 16,0 16,9 12,4 15,7 14,1 velocity vmax [m/s 10,0 6,0 5,0 5,0 5,0 acceleration amax [m/s² 140 80 60 60 60 8 10 12 15 20 25 30 35 40 42,5 8 0,10 0,05 10 0,10 0,05 12 0,10 0,05 15 0,10 0,05 20 0,10 0,05 25 0,10 0,05 30 0,10 0,05 35 0,10 0,05 40 0,10 0,05 42,5 0,10 0,05 0,05 independent from measurement range 0,02 independent from measurement range 0,28 357,14 333,33 1,4 1,5 2,8 3 5,6 6 14 15 available resolution range 10 ­ 42,5 m [pulses mm 0,3 reduced to 60 with option ip67

[close]

p. 5

-5 befestigungsmöglichkeiten technical drawing 8 m range analogue output 8 m range digital output output cable axial radial connector axial connector radial b 54,3 64,3

[close]

p. 6

-6 befestigungsmöglichkeiten technical drawing 10 12 m range position of rope outlet start of meas range x end of meas range x 10 m 33 18 12 m 36 18 15 20 m range position of rope outlet start of meas range x end of meas range x 15 m 41 18 20 m 48 18

[close]

p. 7

-7 befestigungsmöglichkeiten technical drawing 25 30 m range position of rope outlet start of meas range x end of meas range x 25 m 56 18 30 m 63 18 35 42,5 m range position of rope outlet start of meas range x end of meas range x 35 m 71 18 40 m 78 18 42,5 m 82 18

[close]

p. 8

-8 befestigungsmöglichkeiten technical drawing dimensions for analogue output dimensions for digital output incremental output cable axial radial connector axial connector radial a 54,3 64,3

[close]

p. 9

-9 befestigungsmöglichkeiten mounting options 1 by using the grooves in the sensor housing the included t-slot nuts can be easily inserted into the grooves of the sensor housing the nuts have a metric thread m6 each sensor up to 20 m measurement range comes with 2 nuts from 20 to 42,5 m for nuts are included 2 by angle clamp brackets the angle clamp brackets feature a bore for m6 screws to fix it on a plate slab or a profile each sensor up to 20 m measurement range comes with 2 brackets from 20 to 42,5 m for brackets are included 2 1 important the grooves of the sensor housing the nuts and brackets are compatible to the aluminium building kit system from item industrietechnik gmbh www.item.info mounting by using brackets position of the grooves befestigungsmöglichkeiten encoder assembly by easy-clamp-mechanism important all incremental and absolute encoders must have a clamping flange diameter 36mm a shaft diameter of 10 mm and a shaft length of 10-20mm 1 please mount the included coupling 1 on the shaft of the encoder and fix the set screw therefore you will need a hexagon screwdriver size 2 be careful that the dimension between contact surface of the encoder and the end of the cylinder bolt is 35mm 2 please mount the encoder into the easy-clamp-flange the cylinder bolt must slip into the spring 2 3 by tightening the radial screw the encoder will be clamped and secured from twisting please use a hexagon screwdriver size 3 1 2

[close]

p. 10

10 analogue output potentiometer voltage divider output supply voltage recommended cursor current noise working temperature temperature coefficient 1 kohm max 30 v 1 µa depending on supply -20 85 °c ± 0,0025 k v v v cursor gnd 0 10 v voltage output output supply voltage max current consumption output current dynamics noise inverse-polarity protection short-circuit proof working temperature temperature coefficient electromagnetic compatibility emc 0 10 v galvanically isolated 4 conductors 12 30 vdc 22,5 ma unloaded max 10 ma min load 1 kohm 3 ms from 0 100 and 100 0 3 mvpp typically max 37 mv pp yes infinite yes permanent -20 85 °c 0,0037 k according to en 61326-1:2006 note gndsignal and gnd may be connected in 3-wire system v v v signal gndsig gnd 4 20 ma current output output voltage supply output current dynamics noise inverse-polarity protection working temperature temperature coefficient electromagnetic compatibility emc 4 20 ma 2 conductors 12 30 vdc max 50 ma in case of error 1 ms from 0 100 and 100 0 0,03 mapp 6 mv pp at 200 ohm yes infinite -20 85 °c 0,0079 k according to en 61326-1:2006 v v a signal connection cable output axial 2,0 metre standard other cable length optional type tpe flexible diameter ø 4,5 mm stranded wire 0,25 mm² temperature range fixed installation -30 85 °c flexible installation -20 85 °c pin 1 2 3 4 wire colour brown white blue black 10 v v signal gnd gnd signal 420 ma v n c signal n c 1 kohm v cursor gnd n c 4-pin m12 connector output socket profile view on solder side of mating connector

[close]

p. 11

11 digital output incremental electrical data linedriver l rs422 ttl-compatible supply voltage current consumption no load max load channel sx50 max load channel sx80 120 max pulse frequency sx50 max pulse frequency sx80 120 min signal level high max signal level low recommended circuit 5 vdc ±5 typical 70 ma max 100 ma ±10 ma ±20 ma 125 khz 300 khz 2,5 v 0,5 v sensor +5 v a z 0v 0v z 120 ohm circuit +5 v a rl 0v rl 1 kohm ub 8 30 v push pull g 8 30 vdc typical 80 ma max 150 ma ± 30 ma ± 30 ma 100 khz 300 khz ub ­ 3 v 2,5 v sensor circuit connection protection class max cable length connector 12-pin counterclockwise cable output 1,5 m ip65 optional ip67 up to 1000 m connector 12-pin counterclockwise cable output 1,5 m ip65 optional ip67 up to 250 m output signal pulses a and b are 90° phase-delayed detection of direction the zsignal recurs with pulse distance z and may be used as point of reference diagramm shows the signal without inverted signals timeline for return of rope 90° 360° a b z 90° z-signal with a/b and-related rope retracting into sensor connection assignment signal 12-pin connector wire colours 0v 10 white ub 12 brown 0 vsens 11 black ub sens 2 violet a 5 green a6 yellow b 8 grey b1 pink z 3 blue z4 red screen housing housing for linedriver l only for long cable lengths it may occur that the operating voltage at the sensor does not suffice due to the output resistance with the sensor lines 0v sens and +ubsens the operating voltage can be checked and if necessary be readjusted at the input connection 12-pin connector output socket profile view on solder side of mating connector only sx80 sx120 cable output radial axial 1,5 metre standard other cable length optional type ul2464 1061 liyy flexible outer diameter ø 6,5 mm stranded wire 0,25 mm² temperature range fixed installation -30 80 °c flexible installation -20 80 °c

[close]

p. 12

12 digital-absolute bus systems output scalable resolution standard resolution at range 8 m [pulses mm max resolution at range 8 m [pulses mm standard resolution at range 10 ­ 42,5 m [pulses mm max resolution at range 10 ­ 42,5 m [pulses mm supply voltage current consumption no load at 24 vdc protection class protection class optional working temperature profibus-dp ja 22,94 183,5 24,58 196,61 10 30 vdc 90 ma ip65 ip67 -20 80 °c canopen ja 22,94 183,5 24,58 196,61 10 30 vdc 65 ma ip65 ip67 -20 80 °c devicenet ja 22,94 22,94 22,94 22,94 10 30 vdc max 290 ip65 -20 80 °c ethercat ja 22,94 183,5 24,58 196,61 10 30 vdc 90 ma ip65 ip67 -20 80 °c ssi nein 22,94 24,58 10 30 vdc 25 ma ip65 ip67 -20 80 °c other encoder types supply voltage resolution cable connector output are available on request technical drawing addition canopen profibus-dp ethercat ssi devicenet connection encoder type profibus-dp canopen devicenet ethercat ssi other connection variants and protocols on request bus terminal cover 3 x m12-connector 2 x male 1 x female removable bus terminal cover 2 x m12-connector 1 x male 1 x female bus terminal cover 2 x m12-connector 1 x male 1 x female bus terminal cover 3 x m12-connector 1 x male 2 x female 12-pin m23-connector pins counterclockwise mating connector con012-s please see encoder manual for detailled connection.

[close]

p. 13

13 accessories cable with mating connector m12 straight and angular k4p for analogue output potentiometer 10v 420a cable with straight connector k4p2m-s-m12 2m k4p5m-s-m12 5m k4p10m-s-m12 10 m cable with angular connector k4p2m-sw-m12 2m k4p5m-sw-m12 5m k4p10m-sw-m12 10 m mating connector m12 straight and angular for analogue output field attachable connector straight connector angular connector d4-g-m12-s d4-w-m12-s cable diameter ø 3 6,5 mm conductor max 0,75 mm² good chemical and oil resistance protection class ip67 temperature range -25 90 °c mode of connection screw terminals mating connector m23 for digital output and ssi con012-s m23 straight female connector 12-pin clockwise fits to male counterclockwise connector metal housing deflection pulley ur2 by using the deflection pulley the rope can be looped around to e g measure in places that are difficult to access or to protect the sensor from inclined traction on the rope several pulleys may be used material anodised aluminium pom mounting by 2 hexagon socket or countersunk screws m6 vertical or horizontal mounting possible ball bearings with special low temperature grease and rs-sealing temperature range -40 80 °c rope extension sv for bridging a greater distance from the measuring target to the sensor a rope extension can be applied the rope clip must not be guided over the deflection pulley please specify the length needed in your order example rope extension of 250 mm sv-250 magnetic clamp mgg1 use the magnetic clamp to quickly attach the rope to metallic objects without any assembly time a rubber coating provides gentle contact e g on varnished surfaces and prevents from slipping due to vibration the magnet consists of a neodym core for an increased adhesive force of 260 n the hook makes it easy to attach the rope clip drill protection digital distance and speed measurement pax use pax display to visualise the covered distance or the speed tacho sensor of the position transducer it enables a transmission of the measurement data to the computer via interface the comparator allows a good-bad-evaluation limit values function inputs analogue output serial interfaces protection class front panel display power supply incremental analogue 2 independent counter 1 tacho sensor 04 20 ma 0 10 v plug in card rs485 rs232 devicenet plug in card ip65 6 digits 11 36 vdc or 85 250 vac for further information please ask for the data sheet of the pax display series.

[close]

p. 14

14 installation · · mount the sensor at the designated place by using the fixing holes before extracting the rope and before attaching the rope to the measuring target open the rope clip not with set screw m4 after the sensor is fully mounted and extract the measuring rope hook the rope clip on the measuring object and close the bracket of the clip for your safety put a screw driver trough the clip to extract the rope check the track of the measuring target on collision with the sensor housing and on exceeding the specified measurement range when installing the sensor make sure that the rubber stopper does not touch the rope outlet connect the electronics according to the sensor type when laying the cables be careful not to under-run the minimal allowed bending radius of the cable 5 x cable diameter the rope must be extracted from the sensor vertically the maximum variation from the vertical is 3° avoid carefully extracting the rope at an inclination since the durability of the instrument would shorten considerably if it is not possible to keep the limit of 3° a deflection pulley has to be used the measuring range the zero point begins after approximately 2 mm extracted rope the mechanical reserve at the end of the measuring range is about 20 mm when mounting outdoors protect the sensor and the rope from ice-formation at temperatures below 0 °c lay the rope preferably in corners or guarded in guidings to prevent pollution or accidental touch when operating the sensor take care not to let the rope snap back by mistake or extract the rope over the specified measurement range as this might destroy the sensor maintenance these instruments are maintenance-free if however the rope is soiled due to adverse environmental conditions it should be cleaned with a cloth drenched in resin-free machine oil · · · · · · · · warning notices · · · · · · don`t let the rope snap back if the rope is retracted freely this may lead to injuries whiplash effect and the instrument may be damaged caution when unhooking and retracting the rope into the sensor never exceed the specified measurement range when extracting the rope don`t try to open the instrument the stored energy of the spring drive may lead to injuries when being mishandled don`t touch the rope when operating the sensor avoid guiding the rope over edges or corners use a deflection pulley instead don`t operate the sensor if the rope is buckled or damaged a ripping of the rope may lead to injuries or damaging the sensor.

[close]

p. 15

15 order code draw wire mechanics for encoder assembly sx135 measurement ranges 10 12 15 20 25 30 35 40 42,5 m e g 10 co135 8 co135 ip67 m4 options hartcoat coating for range 8 m hartcoat coating for range 10 42,5 m protection class ip67 m4 rope fixation easy-clamp-mechanism f58k order code analogue output sx135 measurement ranges 8 10 12 15 20 25 30 35 40 42,5 m e g 10 co135 8 co135 in l05 ip67 m4 options hartcoat coating for range 8 m hartcoat coating for range 10 42,5 m inverted output signal improved linearity 0,05 protection class ip67 m4 rope fixation analogue output potentiometer voltage output current output 1 kohm 0 10 v 4 20 ma 1r 10v 420a connection sa ka m12 connector output axial cable output axial order code digital digital-absolute bus systems sx135 measurement ranges 8 10 12 15 20 25 30 35 40 42,5 m e g 10 co135 8 co135 l02 ip67 m4 options hartcoat coating for range 8 m hartcoat coating for range 10 42,5 m improved linearity 0,02 protection class ip67 m4 rope fixation digital output [pulses mm 8 m 0,28 1,4 2,8 5,6 14 10 42,5 m 0,3 1,5 3 6 15 e g 14 e g 15 connection digital-absolute bus systems ssi profibus-dp canopen devicenet ethercat ssi pro can dvn cat sa sr ka kr connector output axial connector output radial cable output axial cable output radial output type l g linedriver rs422 push-pull antivalent we reserve the right to alter the specification without prior notice waycon positionsmesstechnik gmbh email info@waycon.de internet www.waycon.de head office mehlbeerenstr 4 82024 taufkirchen tel +49 089 67 97 13-0 fax +49 089 67 97 13-250 office köln auf der pehle 1 50321 brühl tel +49 02232 56 79 44 fax +49 02232 56 79 45

[close]

Other Publications

Waycon Ultrasonic UFA1003/UFA1503

Waycon Ultrasonic UFA1003/UFA1503

Ultrasonic distance sensors are working contactless and can still detect small objects.

Tags: ultrasonic, waycon, distance measurement, transducer, level measurement, displacement transducers, positional measurement, distance sensor, angle measurement, length measurement, positional sensor, path sensor, transducers sensor
Waycon Anzeige Serie PAXI

Waycon Anzeige Serie PAXI

Waycon ist Spezialist und Hersteller von praezisen Messdatenerfassungen, und professioneler Sensorik fuer Industrie und Forschung, fuer alle messtechnischen Anwendungen der Positionsmesstechnik, Wegmesstechnik, Fuellstandsmessung, Abstandsmessung und Wink

Tags: Sensoren, wegmesstechnik, positionsmessung, abstandsmessung, winkelmessung, positionsmesstechnik, Wegsensoren, Wegaufnehmersysteme, Laengenmesstechnik, Wegmessung, Sensorik, Messdatenerfassung, Multifunktionsanzeige, Messauswertung, Sensorenspeisung, Wegaufnehmer Distanzsensoren, Messbereiche, Massstab, Anzeigenmessung
Waycon Ultraschallsensor Serie UX micro

Waycon Ultraschallsensor Serie UX micro

Ultraschallsensoren arbeiten berührungslos und sind durch ihre Gehäuseausführung sowie die Schutzklasse IP67 unempfindlich gegen Wasser, Schmutz, Staub und Chemikalien.

Tags: Sensoren, messtechnik, wegmesstechnik, abstandsmessung, wegaufnehmer, winkelmessung, positionsmesstechnik, Wegsensoren, Wegaufnehmersysteme, Laengenmesstechnik, Wegmessung, Distanzsensoren, Sensorik, Messbereiche, Massstab, Fuellstandsmessung, Ultraschallsensoren, Ultraschallmesstechnik, Abstandsensor, Nährungssensor
Waycon Linear Potentiometer LZW2

Waycon Linear Potentiometer LZW2

Linear potentiometer are well known displacement transducers. The working principle is a voltage division on a hybride conductive film.

Tags: waycon, Potentiometer, Linearpotentiometer, distance measurement, position measurement, position transducers, displacement transducers, angle measurement, precise measurement, transducers, detection methods, linear potentiometer, path sensor, path measurement, displacement transducer, resistance position transducer, potentiometric
Waycon Display Control LH

Waycon Display Control LH

Waycon is a specialist and manufacturer of digital magnetic scales for the positional measurement and quality control and professional sensors for the industry and research.

Tags: Sensor, waycon, distance measurement, transducer, display units, configurable indicating, alarm units, digital panel meters, measurement data, multifunctional display, sensor feed

Comments

no comments yet

YOUBLISHER
About
What Others Say
Sitemap
Impressum

PUBLISHERS
Login
Signup
Tutorials
FAQ
Support

BUSINESS
Overview
Advertising
Support

DEVELOPERS
API

LEGAL
Report a Copyright Violation
Copyright FAQ
Terms of Use
Privacy Policy