Waycon Mehrstellenmessvorrichtung Serie MG10 [view full mode]

p.  1

Embed or link this publication

Description

Die Messtaster von Magnescale® sind hochgenaue Messgeräte mit einem Auflösungsvermögen bis zu 0,1 µm. Sie arbeiten nach dem bewährten Magnescale-Prinzip und liefern ein inkrementales Ausgangssignal.

Popular Pages


p. 1

mg system structure mg gauge system for multi-point measuring series flexible digital main module model name power source · up to 64 connectable gauges · input resolutions 0.1 m 0.5 m 1 m 5 m and 10 m · compatible with rs-232c bcd · operating voltage 12-24vdc · din rail mounting 35mm interface unit communication supply voltage power consumption inrush current 10ms power supply protection communication i/f baud rate setting data length stop bit parity delimiter maximum number of linkages maximum length of linking cable linkage function input format i/o output format input signal output signal counter modules interface modules connectable modules mg10-p2 dc12-24v11-26.4vmin startup time 100ms or less 2.0w total power consumption for connected modules1 10a or less when maximum number of modules are connected fuse 5a fuse is built in rs-232c eia-232c or equivalent 2400 9600 19200 38400 bps set with dip switch 7 8 bit set with dip switch 1 2 bit set with dip switch none odd even set with dip switch cr cr+lf set with dip switch 16 total of counter modules 64 10m source input com sink input ­com photo coupler insulation external power dc5 ­ 24v sink type ­com source type com photo coupler insulation external power dc5 ­ 24v reset pause start latching and data out trigger to whole channels integrated alarm mg20-dk mg20-dg and mg-20dt available for mixed use up to 16 modules 1 mg30-b1,mg30-b2 mg10-p1 1 total power of modules connected to mg10 should not be over 54w 12vdc input or 108 w 24vdc input counter module mg10-p1/p2 mg20-dt/dg/dk mg30-b1/b2 mg multi interface unit operates with a variety of modules counter module mg20 · digital gauge input · resolution setting model name power consumption corresponding gauge measuring unit input allowable resolution setting 2 mg20-dk 1w power consumption for connected gauge dk series a/b quadrature input 10 5 1 0.5 0.1 m maximum response speed reference point 3 others alarm mg20-dg 1.4w connected to dg-b 0.5w connected to dl-b dg b series dl b/dl br series 10 5 0.5 m set with dip switch subject to the specification of the connected gauge mg20-dt 0.8w dt series 5 m dt12/32 1 m dt512 1m s ­ ref-led reference point loaded shows on the display after the reference point is detected set 0 or preset value on the counter when the reference point is detected 33.1/1.3 64/2.52 20.5/0.81 64/2.52 20.5/0.81 64/2.52 s-alm led activates by excess speed/acceleration of measuring unit c-alm led activates by excess speed of the internal circuit of counter alarm display is cancelled by reset command from mg10 or with the reset button of main unit 2 set the resolution value of the connected gauge 3 mg20-dg work only connect to dl br series unit no 108.5/4.27 108.5/4.27 105.5/4.15 105/4.13 105/4.13 99/3.9 reset 232c-set 99/3.9 99/3.9 i/f module mg30 · bcd go no go output · expansion module sequential lineup address res rs-232c mg20-dk dir main module mg10 · power supply · rs-232c connection · connection with counter module i/f module mg10-p1 sink type output ­com mg10-p2 source type output com mg20-dk dk series gauges mg20-dg dg b and dl b/br series gauges mg20-dt dt series gauges interface module model name power consumption input format i/o output format input signal output signal output setting all models operating temperature storage temperature mg30-b1 1w source input com photo coupler insulation external power dc5 ­ 24v sink type ­com mg30-b2 sink input ­com link-in i/o dc-in link-out fg sig bcd i/o 35.65/1.40 4.35/0.17 64.5/2.54 23/0.91 4.35/0.17 64.5/2.54 24.5/0.96 64.5/2.54 unit mm/inch mg30-b1 bcd sink type output ­com mg30-b2 bcd source type output com source type com photo coupler insulation external power dc5 ­ 24v drq channel address measuring mode shifting comparator shifting reset start posing reference point loaded bcd data 6 digits ready code go/no go output alarm reference point loaded timer 1~128ms out or polarity set with internal dip switch 0 50°c no condensation ­10 60°c 20~90%rh mg series system structures sequencer the mg series is a modular gauging system that allows flexible multi-point measuring with built-in software for today s most popular output protocols the mg system can be easily mounted to a standard din rail 35mm requires minimal wiring and can be easily expanded for future upgrades conventional system structure bcd rs-232c sequencer mg30 mg10 counter counter counter counter dk series resolution 0.1/0.5 m dg b/dl series resolution 0.5 m /5 m /10 m conventional systems require one bcd cable per gauge axis the mg series however only requires one bcd cable in addition the mg series is connectable to our dk dg dt and dl series gauges max16ch dt12,dt32 resolution 5 m dt512 resolution 1 m 28 29

[close]

Comments

no comments yet