p. 1
30 wide 1 and 2 evaporator compact cubers technical training
[close]
p. 2
presentation topics · · · · · · models covered components installation electrical sequence service diagnosis refrigeration system
[close]
p. 3
cm3 cm cubed · compact modular cubers overflow drain type cme256 cme506 cme656 cme806 · similar technology used in sce275 · purge valve drains used in cme306 cme456 cme686 cme810 cme1056 cme1356 cme1656 cme1856 cme2006
[close]
p. 4
cabinet · 30 wide cm3 models fit many bins and dispensers · htb250 htb350 htb555 · id200 id250 hd356 30 wide front removable top and side panels · snap screw front panel attachment · no screws in back or top
[close]
p. 5
front panel · removal of front panel provides access to controller water valve water pump · evaporator cover behind it provides a thermal barrier water barrier
[close]
p. 6
front view disposable air filter one on each side hi voltage box autoiq controller water level sensor water compartment
[close]
p. 7
hi voltage box ptcr a c series single phase d series higher use ptcr for single phase
[close]
p. 8
autoiq control system · · · · · · all electronic microprocessor controlled measures water level for cube size no altitude or ambient adjustments needed freeze up protection electric-eye ice sensors bin control new controller in 2002 blue box but same operation as prior black controller last 2 errors can be recalled displays eeprom code at power up universal service controller fits all cm3
[close]
p. 9
control system · controller collects stores and uses data to determine pump and fan off time freeze times end of harvest time reservoir flush time bin full water or refrigeration errors water level/cube size
[close]
p. 10
control system water temperature sensor autoiq controller right bin control ice sensor discharge temperature sensor left bin control ice sensor water level sensor
[close]
p. 11
autoiq controller · adaptive harvest optimizes harvest time · autorestart after power interruptions after water interruptions after long harvest or freeze · antislush first three cycles after restart · indicator lights easier diagnostics
[close]
p. 12
autoiq controller low voltage in/out water valve hot gas valve contactor coil stacking/thermostat push buttons not used thermistors bin control/ice sensor bin control/ice sensor reservoir water level sensor factory use indicator lights bin full freeze harvest clean off water refrigeration diagnostic indicators hi voltage water pump fan motor
[close]
p. 13
controls water system · water enters in harvest thru solenoid valve gravity drain overflow · uses a standpipe in the reservoir to control maximum water height · control system calculates each cycle s water flow rate and adjusts for it benefit overflows the same amount of water under different water flow conditions which provides an assured amount of rinse water · water overflow amount is manually adjustable for variations in water quality
[close]
p. 14
controls water system · inlet water solenoid valve · these four models use the low flow rate valve low flow rate valve used on 7 different modular models and the sce275 high flow rate valve used on the 5 other modular models · all are 24 volt · large screen for dirt resistance benefit only two valves to stock for entire cm3 line
[close]
p. 15
water system · ice water separated by the cube deflector located under the evaporators cube deflector
[close]