powermaxcomplete panel fully supervised wireless alarm control system 1 introduction welcome to powermaxcomplete wireless alarm system this guide provides step by step information that will help you to easily install and run the system and to perform basic configuration changes quick guide the system configuration is shown in figure 1 tel sms gsm telephone gprs internet exchange central monitoring station emergency pendant transmitters door or window open/close detector universal perimeter protection detector wireless detectors up to 28 units installed in the protected premises local computer option wireless sirens router internet user computer site internal siren or strobe smoke detector tel line temperature detector motion detector site external sirens public telephone exchange 4 private telephones flood detector co gas detector up to 8 proximity tags away hard wired detector keyfob 2-way keyfob transmitter transmitter a combination of up to 8 up to 2 up to 8 keypad wireless devices remote commanders wired remote speech box central monitoring stations figure 1 system configuration d-302887 1
[close]
p. 2
2 back-up battery insertion front unit battery cable figure 2 battery insertion 3 mounting on a wall 1 release screws back unit 3 mark 4 drilling points on mounting surface drill 4 holes and insert wall anchors 4 fasten the back unit with 4 screws 5 figure 3 mounting on a wall 2 d-302887
[close]
p. 3
4 wiring phone wiring in north america 8-position rj-31x plug brown red green 1 rj-31x jack gray 2 3 4 6 5 red line from street brown rj-31x 7 grn house phones rj-31x cord gray note for whole house line seizure with dsl service present on the phone line you must install a filter it is suggested to use the dsl alarm filter model manufactured by excelsus technologies or equivalent this filter simply plugs into the rj31x jack and allows alarm reporting without breaking the internet connection zone 29 siren wiring magnetic contact or any other contact not a detector 2.2 k alarm n.c site external siren mg electronics mg441pds or similar siren 6-12vdc 150ma max figure 4 wiring d-302887 3
[close]
p. 4
5 controls and indicators indicators display power next emergency hold for 2 sec volume up record message volume down play message mute speaker chime on/off event log cancel entry delay press both for panic alarm arm chime trouble show/ok fire hold for 2 sec arming away pgm output on arming home pgm output off disarming pgm control move back partition figure 5 controls indicators 6 devices installation fig 6 next k9-85 mcw installation fig 7 mct-320 installation magnet 2 push catch and remove board 3 insert battery front tamper switch back tamper switch option remove spacer 1 3mm spacer a fasten the spacer to mounting surface with 2 screws b locate the magnet on the spacer at the correct direction and push it upward 2 1 release screw and remove cover 4 mounting note it is highly recommended to attach the transmitter to the top of the door/window on the fixed frame and the magnet to the movable part door or window make sure that the magnet is located not more than 6 mm 0.25 in from the transmitter s marked side fig 8 mct-234 usage on surface in corner notes 1 keep away from heat sources 2 do not expose to air drafts 3 do not install outdoors 4 avoid direct sunshine 5 keep wiring away from power cables 6 do not install behind partitions 7 mount on solid stable surface pressing both away home initiates a panic alarm disarm away home aux 4 d-302887
[close]
p. 5
7 defining zone type name chime zones partition you can assign a type and name to each of the system s wireless wired zones actions 1 2 3 4 5 6 7 8 press press enter installer code 9999 by default press press enter zone 01 to 29 e.g 05 press press select zone type with e.g 24h silent and press twice 3 times resultant display installer mode enter code 1 new instl code 3 define zones zone no zone no 05 z05 type black box means that a wireless device is already enrolled to the zone no dark box means that the zone is free entering installer menu 5 24h silent z05 name black box means that a zone type is defined no black box means that no zone type is defined 9 press 10 press select zone name with e.g front door twice and press z05 front door z05 chime 11 press 12 press select zone chime feature with e.g melody chime and press twice z05 partition z05 p1 p2 p3 13 enter zone e.g 05 and press select partition #1 2 or 3 by key 1 key 2 or key 3 respectively e.g 2 and press twice z05 p1 p2 p3 8 piezo siren enable/disable actions 1 2 3 4 5 enter into installer menu see par 8 press press press select siren on or off with and press 23 times 3 times resultant display 4 define panel 01 entry delay 1 24 piezo siren black box means that the siren is enabled piezo siren on the default setting is piezo siren on d-302887 5
[close]
p. 6
9 defining exit delay actions 1 2 3 4 5 6 enter into installer menu see par 8 press press press press select delay with and press the default exit delay time is 60 s 2 times 3 times resultant display 4 define panel 01 entry delay 1 03 exit delay exit delay 60 s 03 exit delay 10 defining entry delay 1/2 actions 1 2 3 4 5 enter into installer menu see par 8 press press press select delay with and press 3 times resultant display 4 define panel 01 entry delay 1 entry dly1 30 s 01 entry delay 1 02 entry delay 2 entry dly2 60 s 6 7 8 press press select delay with and press 02 entry delay 2 the default entry delay 1 time is 30 s the default entry delay 2 time is 60 s 6 d-302887
[close]
p. 7
11 setup for gprs/bb no phone line step 1 do not make any program changes in define com other than those shown on this instructions unless necessary notes 1 before continuing remove power ac and battery and install a sim card provisioned for gprs data service 2 request a sim card phone number from your sim supplier if you wish to have the ability to arm disarm via text messaging or program from the central station receiver actions 1 2 3 4 5 6 7 8 9 press press 3 times once resultant display installer mode enter code 1 new inst code 5 define comm 1:pstn/gsm 2:gprs/bb gprs report disable enable gprs report gprs apn enter installer code 9999 by default press press press press press press 4 times once once once once once twice 3 times once 10 press 11 press 12 press apn 13 enter access point name airnet1 example seaguard sim airnet1 key #8 scroll symbols up key #2 scroll symbols down key #5 toggle uppercase lowercase 14 press 15 press 16 press twice once once gprs apn
[close]
p. 8
12 setup for c.s reporting no phone line step 2 actions 1 2 3 4 5 6 7 8 9 press press 3 times once resultant display installer mode enter code 1 new inst code 5 define comm 1:pstn/gsm 3:c.s reporting report events 1st rprt method disable cellular cellular 1st rprt method ip rcvr 1 000.000.000.000 069.074.192.027 ip rcvr 1 ip rcvr 2 000.000.000.000 208.017.225.027 ip rcvr 2 line fail report pstn 5 minutes don t report don t report pstn
[close]
p. 9
13 setting user codes you can program a security code for yourself and additional 7 codes for other system users actions 1 2 3 4 5 6 7 8 9 press press enter master user code 1111 by default press press press the user code is 1111 by default enter 4 digit code e.g 6854 press press 4 times 2 times resultant display user settings enter code set bypass set user codes user code 1 user code 1 1 1 1 1 user code 1 6 8 5 4 user code 1 6 8 5 4 user code 2 user code 2 user code 2 0 0 0 0 user code 2 2 3 5 1 access to part u02 p1 u02 p1 p2 p2 p3 p3 entering user settings menu 10 press 11 press 12 enter 4 digit code e.g 2351 13 press 14 press select partition by push buttons 1 2 and 3 for partition 1&3 enter 13 15 press 16 press 17 press twice user code 2 as required for the other user codes 3-8 and act as in steps 11-15 set user codes 14 gprs diagnostics actions 1 2 3 4 5 6 7 press press 3 times once resultant display installer mode enter code 1 new inst code 10.diagnostics wl sensors test gprs conn test please wait enter installer code 9999 by default press press press press 6 times once 3 times once note panel rssi must be good or strong not poor visonic has external gsm antennas available in 10 or 20 lengths d-302887 9
[close]
p. 10
messages that may be reported to installer after test lcd message 1 2 3 4 5 6 7 8 unit is ok gsm com loss pin code failure gsm net failure sim card failure gsm not enrolled no gprs service gprs conn fail description gsm global system for mobile communications gprs general packet radio service is working properly rs-232 communication with modem failed missing or wrong pin code only if sim card pin code is enabled modem failed registration to local gsm network creg sim card is not installed correctly in gsm modem gsm auto enroll failed to detect gsm modem gprs network is not available to work with the current sim card meaning the sim card is not open for gprs cgatt see note 1 local gprs network is not available or wrong gprs apn user and password at+gprs see note 1 9 10 11 12 srvr unavailable srvr ip missing apn is missing sim card locked fail opening tcp socket with server problem with server or wrong server ip or no acknowledge received from server at#sktd server ip 1 and #2 are not configured apn access point name is not configured after entering a wrong pin code 3 consecutive times the sim is locked to unlock it a puk pin unlock key number should be entered the puk cannot be entered by the powermax this can be fixed by installing the sim in a personal cellphone and performing the unlock function 13 denied by server the ipmp replied duh to sia-over-ip event message duh means that the ipmp cannot handle the message because the panel is not defined or the message is not decrypted correctly note 1 after sim card provisioning the control panel must be power cycled 15 diagnostic testing actions 1 2 3 4 5 6 enter into installer menu see par 8 press press press walk test the entire protected site to trigger all the sensors review all the results by pressing repeatedly to see all the results if you get a poor display from a certain sensor relocate it and re-test until the result is good or strong 9 times resultant display 10 diagnostics wl sensors test diag testing front door alternately z1 strong back door alternately z2 good 10 d-302887
[close]
p. 11
16 pstn reporting to central station actions 1 2 3 4 5 6 7 8 9 press press 3 times once resultant display installer mode enter code 1 new inst code 5 define comm 1:pstn/gsm 3:c.s reporting report events 1st report method disable pstn pstn 1st rprt method
[close]
p. 12
visonic ltd israel p.o.b 22020 tel-aviv 61220 israel phone 972-3 645-6789 fax 972-3 645-6788 visonic inc u.s.a 65 west dudley town road bloomfield ct 06002-1376 phone 860 243-0833 800 223-0020 fax 860 242-8094 visonic ltd uk unit 6 madingley court chippenham drive kingston milton keynes mk10 0bz tel 0870 7300800 fax 0870 7300801 product support 0870 7300830 visonic gmbh d-a-ch kirchfeldstr 118 d-40215 dÜsseldorf tel +49 0211 600696-0 fax +49 0211 600696-19 visonic iberica isla de palma 32 nave 7 polÍgono industrial norte 28700 san sebastiÁn de los reyes madrid espaÑa tel 34 91659-3120 fax 34 91663-8468 www.visonic-iberica.es internet www.visonic.com © visonic ltd 2010 powermaxcomplete quick guide d-302887 rev 0 10/10 12 d-302887