p. 1
catalog number notes type features specifications intended use streets walkways parking lots and surrounding areas construction rugged die-cast single piece aluminum housing with nominal wall thickness of 1/8 die-cast doorframe has impact-resistant tempered glass lens 3/16 thick doorframe is fully gasketed with one-piece tubular silicone finish standard finish is dark bronze ddb corrosion-resistant polyester powder finish with other architectural colors available optical system miro finish segmented reflectors for superior uniformity and control reflectors attach with tool-less fastener and are rotatable and interchangeable four full cutoff distributions available type ii roadway type iii asymmetric type iv sharp cutoff forward throw and type v symmetric square electrical system 50w-150w utilizes a high reactance high power factor ballast 35s utilizes a reactance high power factor ballast 175w metal halide utilizes a constantwattage auto transformer ballast ballasts are copper wound and 100 factory tested porcelain medium-base socket with copper alloy nickel-plated screw shell and center contact listing listed and labeled to ul standards for wet locations listed and labeled to csa standards see options nom certified see options ip65 rated architectural area roadway lighting mr1 metal halide 50w-175w high pressure sodium 35w 150w specifications length 24.5 62.23cm dia 18.625 47.3075cm overall height 6.375 16.1925cm max weight 27 lbs 12.2 kg epa 0.541 all dimensions are inches centimeters unless otherwise specified ordering information choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line example mr1 175m sr3 tb lpi mr1 series mr1 voltage 120 2083 2403 277 347 4803 tb4 tbv 5 ballast metal halide and highpressure sodium blank standard magnetic ballast cwi constant wattage isolated6 pulse-start metal halide scwa super cwa ballast options shipped installed in fixture sf single fuse 120 277 347v8,9 df double fuse 208 240 480v8,9 per nema twist-lock receptacle only no photocontrol cr corrosion-resistant finish epoxy clear coat over paint qrs quartz restrike system9,10 hs houseside shield sr2 sr3 ec emergency circuit tp tamper-proof csa listed and labeled to canadian safety standards nom nom certified shipped separately11 pe1 nema twist-lock pe 120 208 240v pe3 nema twist-lock pe 347v pe4 nema twist-lock pe 480v pe7 nema twist-lock pe 277v sc shorting cap for per option mr1vg vandal guard lamp 12 lpi lamp included l/lp less lamp wattage metal halide 50m1 70m1 100m 150m 175m high pressure sodium 35s2 50s 70s 100s 150s distribution sr2 segmented type ii roadway sr3 segmented type iii asymmetric sr4sc segmented type iv forward throw sharp cutoff sr5s segmented type v symmetric square mounting spa square pole mounting std rpa round pole mounting wba wall bracket up or down7 notes 1 not available with 480v 2 120v only 3 consult factory for availability in canada 4 optional multi-tap ballast 120 208 240 277v 120 277 347v in canada 5 optional penta-tap ballast 120 208 240 277 480v not available in canada 175w metal halide only 6 isolated two-coil system meets canadian electrical code requirements for 208v 240v and 480v applications 7 mounted in lens up orientation fixture is damp location rated 8 must specify voltage not available with tb or tbv 9 sf df or qrs options cannot be ordered together 10 lamp by others 11 may be ordered as an accessory 12 must be specified when ordering poles specify the appropriate drilling pattern see below example example ssa 20 4c dm19as dm19as 1 at 90 degrees dm28as 2 at 180 degrees dm29as 2 at 90 degrees dm39as 3 at 90 degrees dm49as 4 at 90 degrees dm32as 3 at 120 degrees round poles only consistent with leed® goals green globestm criteria for light pollution reduction outdoor sheet mr1-m-s al 160
[close]
p. 2
mr1 metal halide high pressure sodium mr1 175m sr3 0.25 0.5 1 1.5 2.5 test no ltl10087 distance in units of mounting height -2 -1 0 1 2 3 4 5 mr1 175m sr4sc test no ltl10088 distance in units of mounting height -2 -1 0 2.5 2.5 1.5 1 0.5 0.25 3 4 5 0 1 2 3 4 5 6 1 2 mr1 175m sr5s test no ltl10089 distance in units of mounting height -2 1.5 -1 0 2.5 1.5 1.5 1 0.5 0.25 1 2 3 4 5 0 1 2 3 4 5 6 0 1 2 3 4 5 6 175w lamp rated 12800 lumens footcandle values based on 20 mounting height classification type iii medium full cutoff 175w lamp rated 12800 lumens footcandle values based on 20 mounting height classification type iv short full cutoff 175w lamp rated 12800 lumens footcandle values based on 20 mounting height classification unclassified type iii very short full cutoff mr1 150s sr3 test no ltl10091 distance in units of mounting height mr1 150s sr4sc test no ltl10092 distance in units of mounting height mr1 150s sr5s test no ltl10093 distance in units of mounting height -2 -1 0 2.5 2.5 1.5 1 0.5 0.25 1 2 3 4 5 0 1 2 3 4 5 6 -2 -1 0.25 0.5 1 1.5 2.5 0 1 2 3 4 5 0 1 2 3 4 5 6 -2 1 -1 0 2.5 1.5 1 1 0.5 0.25 3 4 5 0 1 2 3 4 5 6 1 2 150w lamp rated 15800 lumens footcandle values based on 20 mounting height classification type iii medium full cutoff 150w lamp rated 15800 lumens footcandle values based on 20 mounting height classification unclassified type iv very short full cutoff 150w lamp rated 15800 lumens footcandle values based on 20 mounting height classification type iii medium full cutoff lithonia lighting outdoor lighting one lithonia way conyers ga 30012-3957 phone 770-922-9000 fax 770-918-1209 www.lithonia.com sheet mr1-m-s ©2006 acuity lighting group inc rev 8/06
[close]
p. 3
catalog number notes type features specifications intended use streets walkways parking lots and surrounding areas construction rugged die-cast single piece aluminum housing with nominal wall thickness of 1/8 die-cast doorframe has impact-resistant tempered glass lens 3/16 thick doorframe is fully gasketed with one-piece tubular silicone finish standard finish is dark bronze ddb corrosion resistant polyester powder finish with other architectural colors available optical system miro finish segmented reflectors for superior uniformity and control reflectors attach with tool-less fastener and are rotatable and interchangeable four full cutoff distributions available type ii roadway type iii asymmetric type iv forward throw and type v symmetric square electrical system electronic high-frequency multi-volt ballast starting temperature 0° f 18° c <10 thd ballasts are mounted on a removable power tray four-pin white thermoplastic body with quick-connect push-in wiring terminals listing listed and labeled to ul standards for wet locations listed and labeled to csa standards see options nom certified see options ip65 rated architectural area roadway lighting mr1 compact fluorescent 42-70w specifications length 24.5 62.23cm dia 18.625 47.3075cm overall height 6.375 16.1925cm max weight 27 lbs 12.2 kg epa 0.541 all dimensions are inches centimeters unless otherwise specified ordering information choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line example mr1 42trt sr3 mvolt lpi mr1 series mr1 wattage 2/32trt 42trt 2/42trt 1 57trt 70trt 1 distribution sr2 segmented type ii roadway sr3 segmented type iii asymmetric sr4sc segmented type iv forward throw sharp cutoff sr5s segmented type v symmetric square voltage 120 277 347 mvolt 2 mounting spa square pole mounting std rpa round pole mounting wba wall bracket up or down3 shipped gmf glr per options installed in fixture internal slow-blow fusing4 internal fast-blow fusing4 nema twist-lock receptacle only no photocontrol cr corrosion-resistant finish epoxy clear coat over paint hs houseside shield sr2 sr3 tp tamper-proof csa listed and labeled to canadian safety standards nom nom certified shipped separately5 pe1 nema twist-lock pe 120 208 240v pe3 nema twist-lock pe 347v pe4 nema twist-lock pe 480v pe7 nema twist-lock pe 277v sc shorting cap for per option mr1vg vandal guard lamp 6 lpi lamp included l/lp less lamp notes 1 dual lamps available with sr3 optic only 2 optional multi-volt electronic ballast capable of operating on any line voltage from 120 to 277v 3 mounted in lens up orientation fixture is damp location rated 4 must specify voltage not available with mvolt 5 may be ordered as an accessory 6 must be specified when ordering poles specify the appropriate drilling pattern see below example example ssa 20 4c dm19as dm19as 1 at 90 degrees dm28as 2 at 180 degrees dm29as 2 at 90 degrees dm39as 3 at 90 degrees dm49as 4 at 90 degrees dm32as 3 at 120 degrees round poles only consistent with leed® goals green globestm criteria for light pollution reduction outdoor sheet mr1-cf al 161
[close]
p. 4
mr1 compact fluorescent area lighting mr1 42trt sr2 test no ltl10094 distance in units of mounting height -2 0.25 0.5 1 -1 0 1 2 3 4 5 0 1 2 3 4 5 6 0 1 2 3 4 5 6 mr1 42trt sr3 test no ltl10095 distance in units of mounting height 0 1 0.5 0.25 2 3 4 5 0 1 2 3 4 5 6 1 -2 0.25 0.5 1 -1 0 1 2 3 4 5 42w lamp rated 3200 lumens footcandle values based on 20 mounting height classification type ii medium full cutoff 42w lamp rated 3200 lumens footcandle values based on 20 mounting height classification type iii medium full cutoff mr1 42trt sr4sc test no ltl10096 distance in units of mounting height -2 -1 0.25 0.5 0 1 2 3 4 5 0 1 2 3 4 5 6 mr1 42trt sr5s test no ltl10097 0.25 -1 42w lamp rated 3200 lumens footcandle values based on 20 mounting height classification unclassified type iv very short full cutoff 42w lamp rated 3200 lumens footcandle values based on 20 mounting height classification unclassified type iii very short full cutoff distance in units of mounting height -2 lithonia lighting outdoor lighting one lithonia way conyers ga 30012-3957 phone 770-922-9000 fax 770-918-1209 www.lithonia.com sheet mr1-cf ©2006 acuity lighting group inc rev 8/06
[close]
p. 5
catalog number notes type features specifications intended use streets walkways parking lots and surrounding areas construction rugged die-cast single piece aluminum housing with nominal wall thickness of 1/8 die-cast doorframe has impact-resistant tempered glass lens 3/16 thick doorframe is fully gasketed with one-piece tubular silicone finish standard finish is dark bronze ddb corrosion resistant polyester powder finish with other architectural colors available optical system non-rotatable reflector discharge vessel/lamp glass bulb that contains a mixture of low-pressure mercury vapor and inert buffer gas the wall of the lamp is coated with a fluorescent powder that produces light at 3500k and an 80 cri induction high frequency generator supplies high-frequency power to the discharge vessel lamp to initiate and maintain a gas discharge for a rated 100,000 hours of life suitable for ambient temperatures ranging from -40° to 20° c one 120v generator 3500k lamp listing listed and labeled to ul standards for wet locations listed and labeled to csa standards see options nom certified see options ip65 rated architectural area roadway lighting mr1 induction 100w standard dimensions mr1 length 24.5 62.23cm dia 18.625 47.3075cm overall height 6.375 16.1925cm max weight 35 lbs 15.9 kg all dimensions are inches centimeters unless otherwise specified ordering information choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line example mr1 100il mvolt lpi mr1 series mr1 100il wattage 100il 1 mvolt voltage mvolt 2 lpi mounting spa square pole mounting std rpa round pole mounting wba wall bracket up or down3 options shipped installed in fixture per nema twist-lock receptacle only no photocontrol cr corrosion-resistant finish epoxy clear coat over paint tp tamper-proof csa listed and labeled to canadian safety standards nom nom certified shipped separately4 pe1 nema twist-lock pe 120 208 240v pe7 nema twist-lock pe 277v sc shorting cap for per option mr1vg vandal guard lamp5 lpi lamp included when ordering poles specify the appropriate drilling pattern see below example notes 1 consult factory for availability in canada 2 multi-volt electronic ballast capable of operating on any line voltage from 120 to 277v 3 mounted in lens-up orientation fixture is damp location listed 4 may be ordered as an accessory 5 must be specified example dm19as dm28as dm29as dm39as dm49as dm32as ssa 20 4c dm19as 1 at 90 degrees 2 at 180 degrees 2 at 90 degrees 3 at 90 degrees 4 at 90 degrees 3 at 120 degrees round poles only outdoor sheet mr1-il al 162
[close]
p. 6
mr1 induction area lighting mr1 100ind induction lamp 0.25 0.5 1 1.5 2.5 test no ltl14901 distance in units of mounting height -2 -1 0 1 2 3 4 5 0 1 2 3 4 5 6 100w lamp rated 8000 lumens footcandle values based on 20 mounting height classification type v full cutoff lithonia lighting outdoor lighting one lithonia way conyers ga 30012-3957 phone 770-922-9000 fax 770-918-1209 www.lithonia.com sheet mr1-il ©2006 acuity lighting group inc 9/06
[close]
p. 7
catalog number notes type features specifications intended use streets walkways parking lots and surrounding areas construction rugged die-cast single piece aluminum housing with nominal wall thickness of 1/8 die-cast doorframe has impact-resistant tempered glass lens 3/16 thick doorframe is fully gasketed with one-piece tubular silicone finish standard finish is dark bronze ddb corrosion-resistant polyester powder finish with other architectural colors available optical system miro finish segmented reflectors for superior uniformity and control reflectors attach with tool-less fastener and are rotatable and interchangeable five full cutoff distributions available type ii roadway type iii asymmetric type iv forward throw type iv forward throw sharp cutoff and type v symmetric square electrical system ballast is a constant-wattage autotransformer standard 200w 320w and 350w require super scwa pulse start ballast must order scwa option all ballasts are mounted on a removable power tray ballasts are copperwound and 100 factory-tested porcelain mogul-based socket with copper alloy nickel-plated screw shell and center contact listing listed and labeled to ul standards for wet locations listed and labeled to csa standards see options nom certified see options ip65 rated architectural area roadway lighting mr2 metal halide high pressure sodium 200w-400w specifications length 32.875 83.5025cm diameter 25 63.5cm overall height 8.25 20.955cm max weight 46 lb 20.9 kg epa 0.914 all dimensions are inches centimeters unless otherwise specified ordering information choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line example mr2 400m sr3 tb lpi mr2 series mr2 voltage 120 2083 2403 277 347 4803 tb4 tbv 5 ballast metal halide and highpressure sodium blank standard magnetic ballast cwi constant wattage isolated6 pulse-start metal halide scwa super cwa ballast llrpsl low-loss reactor pulse start options shipped installed in fixture sf single fuse 120 277 347v8,9 df double fuse 208 240 480v8,9 per nema twist-lock receptacle only no photocontrol cr corrosion-resistant finish epoxy clear coat over paint qrs quartz restrike system9,10 hs houseside shield sr2 sr3 ec emergency circuit10 tp tamper-proof csa listed and labeled to canadian safety standards nom nom certified shipped separately11 pe1 nema twist-lock pe 120 208 240v pe3 nema twist-lock pe 347v pe4 nema twist-lock pe 480v pe7 nema twist-lock pe 277v sc shorting cap for per option mr2vg vandal guard lamp 12 lpi lamp included l/lp less lamp wattage metal halide 200m1 250m 320m1 350m1,2 400m1,2 high pressure sodium 200s 250s 400s distribution notes 1 2 3 4 5 6 7 sr2 segmented type ii roadway sr3 segmented type iii asymmetric sr4sc segmented type iv forward throw sharp cutoff sr4w segmented type iv wide forward throw sr5s segmented type v symmetric square mounting spa square pole mounting std rpa round pole mounting wba wall bracket up or down7 must order with scwa must use reduced jacket lamp ed28 consult factory for availability in canada optional multi-tap ballast 120 208 240 277v 120 277 347v in canada optional penta-tap ballast 120 208 240 277 480v not available in canada 175w metal halide only isolated two-coil system meets canadian electrical code requirements for 208v 240v and 480v applications mounted in lens up orientation fixture is damp location rated when ordering poles specify the appropriate drilling pattern see below example example ssa 20 4c dm19as dm19as 1 at 90 degrees dm28as 2 at 180 degrees dm29as 2 at 90 degrees dm39as 3 at 90 degrees dm49as 4 at 90 degrees dm32as 3 at 120 degrees round poles only 8 must specify voltage not available with tb or tbv 9 sf df or qrs cannot be ordered together 10 lamp by others 11 can be ordered as an accessory 12 must be specified consistent with leed® goals green globestm criteria for light pollution reduction outdoor sheet mr2-m-s al 163
[close]
p. 8
mr2 metal halide high pressure sodium mr2 400m sr3 test no ltl10099 distance in units of mounting height mr2 400m sr4sc test no ltl10100 distance in units of mounting height -2 -1 0.25 0.5 1 1.5 2.5 5 0 1 2 3 4 5 0 1 2 3 4 5 6 mr2 400m sr4w test no ltl10101 distance in units of mounting height distance in units of mounting height -2 -1 0 5 2.5 1.5 1 0.5 0.25 1 2 3 4 5 0 1 2 3 4 5 6 -2 -1 0 5 2.5 1.5 1 0.5 0.25 4 5 0 1 2 3 4 5 6 1 2 3 400w lamp rated 32000 lumens footcandle values based on 20 mounting height classification type iii medium full cutoff 400w lamp rated 32000 lumens footcandle values based on 20 mounting height classification unclassified type iv very short full cutoff 400w lamp rated 32000 lumens footcandle values based on 20 mounting height classification type iv short full cutoff mr2 400m sr5s test no ltl10102 distance in units of mounting height -2 2.5 -1 0 5 2.5 2.5 1.5 1 0.5 0.25 1 2 3 4 5 0 1 2 3 4 5 6 mr2 400s sr3 test no ltl10104 distance in units of mounting height -2 -1 0 mr2 400s sr4sc test no ltl10105 -2 -1 0.25 0.5 1 1.5 2.5 5 0 1 2 3 4 5 0 1 2 3 4 5 6 5 2.5 1.5 1 0.5 0.25 1 2 3 4 5 0 1 2 3 4 5 6 400w lamp rated 32000 lumens footcandle values based on 20 mounting height classification unclassified type iv very short full cutoff 400w lamp rated 50000 lumens footcandle values based on 20 mounting height classification type ii medium full cutoff 400w lamp rated 50000 lumens footcandle values based on 20 mounting height classification unclassified type iv very short full cutoff lithonia lighting outdoor lighting one lithonia way conyers ga 30012-3957 phone 770-922-9000 fax 770-918-1209 www.lithonia.com sheet mr2-m-s ©2006 acuity lighting group inc rev 8/06
[close]
p. 9
catalog number notes type features specifications intended use streets walkways parking lots and surrounding areas construction rugged die-cast single piece aluminum housing with nominal wall thickness of 1/8 die-cast doorframe has impact-resistant tempered glass lens 3/16 thick doorframe is fully gasketed with one-piece tubular silicone finish standard finish is dark bronze ddb corrosion resistant polyester powder finish with other architectural colors available optical system non-rotatable reflector discharge vessel/lamp glass bulb that contains a mixture of low-pressure mercury vapor and inert buffer gas the wall of the lamp is coated with a fluorescent powder that produces light at 3500k and an 80 cri induction high frequency generator supplies high-frequency power to the discharge vessel lamp to initiate and maintain a gas discharge for a rated 100,000 hours of life suitable for ambient temperatures ranging from -40° to 20° c one 120v generator 3500k lamp listing listed and labeled to ul standards for wet locations listed and labeled to csa standards see options nom certified see options ip65 rated architectural area roadway lighting mr2 induction 150w specifications length 32.875 83.5025cm diameter 25 63.5cm overall height 8.25 20.955cm max weight 46 lb 20.9 kg epa 0.914 all dimensions are inches centimeters unless otherwise specified ordering information choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line example mr2 150il mvolt lpi mr2 series mr2 150il wattage induction 150il1 mvolt voltage mvolt 2 mounting spa square pole mounting std rpa round pole mounting wba wall bracket up or down3 options shipped installed in fixture per nema twist-lock receptacle only no photocontrol cr corrosion-resistant finish epoxy clear coat over paint tp tamper-proof csa listed and labeled to canadian safety standards nom nom certified shipped separately4 pe1 nema twist-lock pe 120 208 240v pe7 nema twist-lock pe 277v sc shorting cap for per option mr2vg vandal guard lpi lamp 5 lpi lamp included notes 1 consult factory for availability in canada 2 multi-volt electronic ballast capable of operating on any line voltage from 120-277v 3 mounted in lens up orientation fixture is damp location rated 4 can be ordered as an accessory 5 must be specified when ordering poles specify the appropriate drilling pattern see below example example ssa 20 4c dm19as dm19as dm28as dm29as dm39as dm49as dm32as 1 2 2 3 4 3 at 90 degrees at 180 degrees at 90 degrees at 90 degrees at 90 degrees at 120 degrees round poles only outdoor sheet mr2-il al-164
[close]
p. 10
mr2 induction area lighting mr2 150ind induction lamp test no ltl14902 -1 0 5 2.5 1.5 1 0.5 0.25 1 2 3 4 5 0 1 2 3 4 5 6 -2 150w lamp rated 12000 lumens footcandle values based on 20 mounting height classification unclassified type ii very short cutoff distance in units of mounting height lithonia lighting outdoor lighting one lithonia way conyers ga 30012-3957 phone 770-922-9000 fax 770-918-1209 www.lithonia.com sheet mr2-il ©2006 acuity lighting group inc rev 12/8/06
[close]
p. 11
catalog number notes type features specifications intended use streets walkways parking lots and surrounding areas construction rugged die-cast single piece aluminum housing with nominal wall thickness of 1/8 die-cast doorframe has impact-resistant tempered glass lens 3/16 thick doorframe is fully gasketed with one-piece tubular silicone finish standard finish is dark bronze ddb corrosion-resistant polyester powder finish with other architectural colors available optical system miro finish segmented reflectors for superior uniformity and control reflectors attach with tool-less fastener and are rotatable and interchangeable four full cutoff distributions available type ii roadway type iii asymmetric type iv forward throw and type v symmetric square electrical system 50w-150w utilizes a high reactance high power factor ballast 35s utilizes a reactance high power factor ballast 175w utilizes a constant-wattage auto transformer ballast ballasts are copper wound and 100 factory tested porcelain medium-base socket with copper alloy nickel-plated screw shell and center contact temperatures ranging from -40° to 20°c one 120v generator installation additional backing plate and receiver used to mount tension rod listing listed and labeled to ul standards for wet locations listed and labeled to csa standards see options nom certified see options ip65 rated architectural area roadway lighting mrt1 metal halide 50w-175w high pressure sodium 35w 150w specifications length 24.5 62.23cm dia 18.625 47.3075cm overall height 6.375 16.1925cm max weight 27 lbs 12.2 kg epa 0.541 all dimensions are inches centimeters unless otherwise specified ordering information choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line example mrt1 175m sr3 tb lpi mrt1 series mrt1 voltage 120 2083 2403 277 347 4803 tb4 tbv 5 ballast metal halide and highpressure sodium blank standard magnetic ballast cwi constant wattage isolated6 pulse-start metal halide scwa super cwa ballast options shipped installed in fixture sf single fuse 120 277 347v8,9 df double fuse 208 240 480v8,9 per nema twist-lock receptacle only no photocontrol cr corrosion-resistant finish epoxy clear coat over paint qrs quartz restrike system9,10 hs houseside shield sr2 sr3 ec emergency circuit tp tamper-proof csa listed and labeled to canadian safety standards nom nom certified shipped separately11 pe1 nema twist-lock pe 120 208 240v pe3 nema twist-lock pe 347v pe4 nema twist-lock pe 480v pe7 nema twist-lock pe 277v sc shorting cap for per option mr1vg vandal guard lamp 12 lpi lamp included l/lp less lamp wattage metal halide 50m1 70m1 100m 150m 175m high pressure sodium 35s2 50s 70s 100s 150s distribution sr2 segmented type ii roadway sr3 segmented type iii asymmetric sr4sc segmented type iv forward throw sharp cutoff sr5s segmented type v symmetric square mounting spa square pole mounting std rpa round pole mounting wba wall bracket up or down7 notes 1 not available with 480v 2 120v only 3 consult factory for availability in canada 4 optional multi-tap ballast 120 208 240 277v 120 277 347v in canada 5 optional penta-tap ballast 120 208 240 277 480v not available in canada 175w metal halide only 6 isolated two-coil system meets canadian electrical code requirements for 208v 240v and 480v applications 7 mounted in lens up orientation fixture is damp location rated 8 must specify voltage not available with tb or tbv 9 sf df or qrs options cannot be ordered together 10 lamp by others 11 may be ordered as an accessory 12 must be specified when ordering poles specify the appropriate drilling pattern see below example example ssa 20 4c dm19mrt1 dm19mrt1 1 at 90 degrees dm28mrt1 2 at 180 degrees dm29mrt1 2 at 90 degrees dm39mrt1 3 at 90 degrees dm49mrt1 4 at 90 degrees dm32mrt1 3 at 120 degrees round poles only consistent with leed® goals green globestm criteria for light pollution reduction outdoor sheet mrt1-m-s al 165
[close]
p. 12
mrt1 metal halide high pressure sodium mr1 175m sr3 0.25 0.5 1 1.5 2.5 test no ltl10087 distance in units of mounting height -2 -1 0 1 2 3 4 5 mr1 175m sr4sc test no ltl10088 distance in units of mounting height mr1 175m sr5s test no ltl10089 distance in units of mounting height -2 1.5 -1 0 2.5 1.5 1.5 1 0.5 0.25 1 2 3 4 5 0 1 2 3 4 5 6 -2 -1 0 2.5 2.5 1.5 1 0.5 0.25 3 4 5 0 1 2 3 4 5 6 1 2 0 1 2 3 4 5 6 175w lamp rated 12800 lumens footcandle values based on 20 mounting height classification type iii medium full cutoff 175w lamp rated 12800 lumens footcandle values based on 20 mounting height classification type iv short full cutoff 175w lamp rated 12800 lumens footcandle values based on 20 mounting height classification unclassified type iii very short full cutoff mr1 150s sr3 test no ltl10091 distance in units of mounting height -2 -1 0 mr1 150s sr4sc test no ltl10092 distance in units of mounting height -2 -1 0.25 0.5 1 1.5 2.5 0 1 2 3 4 5 0 1 2 3 4 5 6 mr1 150s sr5s test no ltl10093 distance in units of mounting height -2 1 -1 0 2.5 1.5 1 1 0.5 0.25 3 4 5 0 1 2 3 4 5 6 1 2 2.5 2.5 1.5 1 0.5 0.25 1 2 3 4 5 0 1 2 3 4 5 6 150w lamp rated 15800 lumens footcandle values based on 20 mounting height classification type iii medium full cutoff 150w lamp rated 15800 lumens footcandle values based on 20 mounting height classification unclassified type iv very short full cutoff 150w lamp rated 15800 lumens footcandle values based on 20 mounting height classification type iii medium full cutoff lithonia lighting outdoor lighting one lithonia way conyers ga 30012-3957 phone 770-922-9000 fax 770-918-1209 www.lithonia.com sheet mrt1-m-s ©2006 acuity lighting group inc rev 8/06
[close]
p. 13
catalog number notes type features specifications intended use streets walkways parking lots and surrounding areas construction rugged die-cast single piece aluminum housing with nominal wall thickness of 1/8 die-cast doorframe has impact-resistant tempered glass lens 3/16 thick doorframe is fully gasketed with one-piece tubular silicone finish standard finish is dark bronze ddb corrosion resistant polyester powder finish with other architectural colors available optical system miro finish segmented reflectors for superior uniformity and control reflectors attach with tool-less fastener and are rotatable and interchangeable four full cutoff distributions available type ii roadway type iii asymmetric type iv forward throw and type v symmetric square electrical system electronic high-frequency multi-volt ballast starting temperature 0°f 18°c <10 thd ballasts are mounted on a removable power tray four-pin white thermoplastic body with quick-connect push-in wiring terminals installation additional backing plate and receiver used to mount tension rod listing listed and labeled to ul standards for wet locations listed and labeled to csa standards see options nom certified see options ip65 rated architectural area roadway lighting mrt1 compact fluorescent 42w 57w 70w specifications length 24.5 62.23cm dia 18.625 47.3075cm overall height 6.375 16.1925cm max weight 27 lbs 12.2 kg epa 0.541 all dimensions are inches centimeters unless otherwise specified ordering information choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line example mrt1 42trt sr3 mvolt lpi mrt1 series mrt1 wattage 2/32trt 1 42trt 2/42trt 1 57trt 70trt distribution sr2 segmented type ii roadway sr3 segmented type iii asymmetric sr4sc segmented type iv forward throw sharp cutoff sr5s segmented type v symmetric square voltage 120 277 347 mvolt 2 mounting spa square pole mounting std rpa round pole mounting wba wall bracket up or down3 shipped gmf glr per options installed in fixture internal slow-blow fusing4 internal fast-blow fusing4 nema twist-lock receptacle only no photocontrol cr corrosion-resistant finish epoxy clear coat over paint hs houseside shield sr2 sr3 tp tamper-proof csa listed and labeled to canadian safety standards nom nom certified shipped separately5 pe1 nema twist-lock pe 120 208 240v pe3 nema twist-lock pe 347v pe4 nema twist-lock pe 480v pe7 nema twist-lock pe 277v sc shorting cap for per option mr1vg vandal guard lamp 6 lpi lamp included l/lp less lamp notes 1 dual lamps available with sr3 optic only 2 optional multi-volt electronic ballast capable of operating on any line voltage from 120 to 277v 3 mounted in lens up orientation fixture is damp location rated 4 must specify voltage not available with mvolt 5 may be ordered as an accessory 6 must be specified when ordering poles specify the appropriate drilling pattern see below example example ssa 20 4c dm19mrt1 dm19mrt1 1 at 90 degrees dm28mrt1 2 at 180 degrees dm29mrt1 2 at 90 degrees dm39mrt1 3 at 90 degrees dm49mrt1 4 at 90 degrees dm32mrt1 3 at 120 degrees round poles only consistent with leed® goals green globestm criteria for light pollution reduction outdoor sheet mrt1-cf al 166
[close]
p. 14
mrt1 compact fluorescent area lighting mr1 42trt sr2 test no ltl10094 distance in units of mounting height -2 0.25 0.5 1 -1 0 1 2 3 4 5 0 1 2 3 4 5 6 0 1 2 3 4 5 6 mr1 42trt sr3 test no ltl10095 distance in units of mounting height 0 1 0.5 0.25 2 3 4 5 0 1 2 3 4 5 6 1 -2 0.25 0.5 1 -1 0 1 2 3 4 5 42w lamp rated 3200 lumens footcandle values based on 20 mounting height classification type ii medium full cutoff 42w lamp rated 3200 lumens footcandle values based on 20 mounting height classification type iii medium full cutoff mr1 42trt sr4sc test no ltl10096 distance in units of mounting height -2 -1 0.25 0.5 0 1 2 3 4 5 0 1 2 3 4 5 6 mr1 42trt sr5s test no ltl10097 0.25 -1 42w lamp rated 3200 lumens footcandle values based on 20 mounting height classification unclassified type iv very short full cutoff 42w lamp rated 3200 lumens footcandle values based on 20 mounting height classification unclassified type iii very short full cutoff distance in units of mounting height -2 lithonia lighting outdoor lighting one lithonia way conyers ga 30012-3957 phone 770-922-9000 fax 770-918-1209 www.lithonia.com sheet mrt1-cf ©2006 acuity lighting group inc rev 8/06
[close]
p. 15
catalog number notes type features specifications intended use streets walkways parking lots and surrounding areas construction rugged die-cast single piece aluminum housing with nominal wall thickness of 1/8 die-cast doorframe has impact-resistant tempered glass lens 3/16 thick doorframe is fully gasketed with one-piece tubular silicone finish standard finish is dark bronze ddb corrosion resistant polyester powder finish with other architectural colors available optical system non-rotatable reflector discharge vessel/lamp glass bulb that contains a mixture of low-pressure mercury vapor and inert buffer gas the wall of the lamp is coated with a fluorescent powder that produces light at 3500k and an 80 cri induction high frequency generator supplies high-frequency power to the discharge vessel lamp to initiate and maintain a gas discharge for a rated 100,000 hours of life suitable for ambient temperatures ranging from -40° to 20° c one 120v generator 3500k lamp installation additional backing plate and receiver used to mount tension rod listing listed and labeled to ul standards for wet locations listed and labeled to csa standards see options nom certified see options ip65 rated architectural area roadway lighting mrt1 induction 100w specifications length 24.5 62.23cm dia 18.625 47.3075cm overall height 6.375 16.1925cm max weight 35 lbs 15.9 kg epa 0.541 all dimensions are inches centimeters unless otherwise specified ordering information choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line example mrt1 100il mvolt lpi mrt1 series mrt1 150il wattage induction 100il1 mvolt voltage mvolt 2 mounting spa square pole mounting std rpa round pole mounting wba wall bracket up or down3 options shipped installed in fixture per nema twist-lock receptacle only no photocontrol cr corrosion-resistant finish epoxy clear coat over paint tp tamper-proof csa listed and labeled to canadian safety standards nom nom certified shipped separately4 pe1 nema twist-lock pe 120 208 240v pe7 nema twist-lock pe 277v sc shorting cap for per option mr1vg vandal guard lpi lamp 5 lpi lamp included notes 1 consult factory for availability in canada 2 multi-volt electronic ballast capable of operating on any line voltage from 120-277v 3 mounted in lens up orientation fixture is damp location rated 4 can be ordered as an accessory 5 must be specified when ordering poles specify the appropriate drilling pattern see below example example ssa 20 4c dm19mrt1 dm19mrt1 dm28mrt1 dm29mrt1 dm39mrt1 dm49mrt1 dm32mrt1 1 2 2 3 4 3 at 90 degrees at 180 degrees at 90 degrees at 90 degrees at 90 degrees at 120 degrees round poles only outdoor sheet mrt1-il al-167
[close]