Continental Worldwide Trading Company

 

Embed or link this publication

Description

CWTC Newsletter September-December 2017

Popular Pages


p. 1

CO2XBRIXMonitorCooRE! SimultaneousMeasurementofCO2andBrixinCarbonatedDrinks Traditionally,theamountofdissolvedcarbondioxideismeasuredusingamethodologycommonlycalled"manualshaking"(akapiercing device)whereacontainerwithpiercedholeisshakenvigorouslyinametalframe.Itrequiresstrenuousphysicalexertionofshakinga2Lbottle andametalframe,whichweighs8.4lbs/3.8kgintotal.TheCooRewasdevelopedtosimplifythistaskasmuchaspossible. Features: -SimultaneousmeasurementofGasvolumeandBrix. -Easymeasurementswhenever,whereverasitweighsonly40Kglessthanconventionalmeters. -Builtinpumpforsuctionandexpulsionofliquid. -CosteffectiveRequiressmallsamplesize-only100ml. -Two-inOneSystem canbeuseinlaboratoryoroperatedviabattery. -Userscalefunctioncaneasilyshiftthedatafrom existingversiontoCooRe. -MeasurementScaleBrix:0.00to20.00%,CO2Concentration:0.0000to12.000vol. AstellAutoclavesYourSterilizationPartnerSince1884 TopLoadingAutoclaves,AMARange-95to135liter -Userfriendlysizesin95,120and135litermodelsandClassic&Autofillversions. -Adelayedstartandamediaholdwarm featureforgreatercontroloverwhenyouwanttosterilize. -Safetyfeaturesover-temperatureprotection,anexternalpressuregauge,acoolinglock,asafetyvalvetest programandanemergencystopbutton. -ColorTouchscreenwithprogrammablecontroller. -Loadsensedprocesstiming;sterilizationcyclestartsonlywhendesiredtemperatureisreachedinsidethe autoclave,communicatedviaaprobeinsertedintotheload.

[close]

p. 2

LabRefrigeratorLKexv3910andLKUexv1610 SafeColdStorageofHazardousMaterials Laboratoryfreezer&refrigeratorsmustmeetverystrictrequirementsrelatedtosafety& temperatureconsistency.Itisimportantto chooseahighperformanceappliancedesignedforthedemandingstandardsofyourlaboratory. Features: -ATEX95;suitableforstoringexplosiveandhighlyflammablesubstancesinsealedcontainers. -Integrateddatamemorywithmax/mintemperature. -Safetythermostattoensurethattemperaturedoesnotfallbelow+2°C. -Comfortelectroniccontrollerenablestemperaturetobesetaccurately. -Selfclosingdoorforconvenientuse. -Availablewithoptionalglassdoors. LKexv1610 TotalGross/NetCapacity 141/130litre TemperatureRange +3°Cto+16°C LKexv3910 TotalGross/NetCapacity 360/344litre TemperatureRange +3°Cto+16°C Applications: ResearchandLaboratory,Food,BeveragesandPharmaceuticalSector. LKexv1610 LKexv3910 NIRMaster™ RealTimeMonitoringforEnhancedQuality&Productivity -Rapid&Fastresultswithminimum samplepreparation. -Precisemeasurementofseveralparametersatonetime. -Twinlampmodule-nodowntimeincaseofprimarylampfailure. -BroadSpectralrange-800to2500nm (12500-4000cm-1). -Housing-foodgradePMMAorstainlesssteelwithlP54orlP65. -Highspectralresolutionof8cm-1leadstohighlyaccuratereadings. -Easyspindrivewithmagneticspinnerforhighperformance. -AvailableinfoodgradePMMAorStainlessSteelhousing. -Certifieddustandsplashwaterprotection(IP54). -SafeoperationduetoembeddedindustrystandardPC. -AlsoavailableasNIRMasterProIP65withahygienicdesignthatiscertifiedto beresistanttowaterjetcleaningproceduresaccordingtoIP65protectionclass. NIRSolutionsacrosstheValueChain Research&Development Incomingmaterials Production FinishedProduct

[close]

p. 3

StorageofCompressedGasCylinder CertifiedSafe&ApprovedStorageofFlammablesorToxicGases OptimalVentilationThatCompliesWiththeInternationalStandards! AsecosGasCylinderCabinetsareuniqueonthemarketwitha60cm widthforthe storageoftwo50litresteelgascylindersortwo40litrealuminium gascylinderswith adiameterof230mm. -Forthesafestorageofupto4gascylinderseachholding50litres. -TypeG30,30minutesfirerated,FurnacetestedinaccordancewithEN14470-2. -Easyinstallationofequipmentandpipes-largeinteriorheightwith,60or48 leadthroughpossibilitiesonthetopofthecabinet. -Nounauthoriseduse-doorslockablewithcylinderlock. -Ventilationwithintegratedairductsforconnectiontoatechnicalexhaustsystem. -Completeanduniform ventilationofthecabinetinteriorfrom thebottom tothetop. -Standardsupplywithmountingrails,rollingramp,cylinderretainer& tensionbelts. PreparativeHPLCLaboACELC-5060 MaximizeRecoveryandPurityofYourCompounds JapanAnalyticalIndustry(JAI)isaninnovativeJapanesecompanythatspecializeinRecyclingPreparativeHPLCandrelatedproductsin thefieldofPreparativeChromatography. ThenewgenerationLaboACEPreparativeHPLCpromisestomakeyourpurification stepssimple,quick&easy. Autocleanupfunction Keepstheflow channelscleanautomatically.Solventchangeoverwhen changingcolumnsisalsomademucheasier. Reliablesolventdeliverypeformance Optimizedserialdoubleplungerpumpdedicatedforrecyclingwithreliable solventdelivery& guaranteedflowrateregardlessofcolumnpressure. UniqueRecyclingEfficiency Minimizedinternaldeadvolumewiththepatentedrecyclingfeature.

[close]

p. 4

GFLShakers-Maximizeyourlab’sefficiency ForGentleMotion,VigorousMixingorIntensiveShaking -Forgentlemotion,vigorousmixingorintensiveshaking -Availablewithfivedifferenttypesofshakingmotion: -OrbitalShakers -ReciprocatingShakers -Orbital-RockingShakers -RockingShaker -VibratingShaker -Easyattachmentofaccessoriesforvariousapplications. -CEmark,lowmaintenance&robustsystems. IWAKILaboratoryGlassware IdealforLaboratoryApplication -Robust,withlowcoefficientofthermalexpansionandincreasedwear&abrasionresistance. -Temperatureresistant,canwithstandhightemperaturesoflab. -MeetingInternationalStandards,ISO-&JapanIndustrialStandards(JIS)certification highaccuracyandrepeatability. -Traceablecertificate-ClassAglasswarearesuppliedwithbatchcertificates. -IWAKIvolumetricwareglasswaresaresuppliedwithoriginalBATCHCERTIFICATEby themanufacture. HIGHQUALITYLABGLASSWARE CompleteLaboratoryGlassware Multi-BranchedFiltrationSystem All-in-OneVacuumFiltrationSystem -Quickfiltrationofamultitudeofsamples. -Strongoil-freevacuumpump. -SUS316stainlesssteelorlightaluminummanifolds. -Individuallycontrollablefiltercups. -Spin-Lockormagneticlockingdesigntoensurequick assemblyandatightsystem. -Noclampsneeded. -Custom-madesystemspossible. GERMAN TECHNOLOGY ContinentalWorldwideTradingCompany RegisteredOffice:Office#203,AmberEstate,Block7-8,K.C.H.SUnionLtd.,Shahrah-e-Faisal,CityP.OBox5134,Karachi-75350,Pakistan. SalesOffice:BungalowD-11FirstFloorP.E.C.H.SBlock-6,CityP.OBox5134,Karachi-75350,Pakistan. Tel.:+92-21-34390472-5,Fax:+92-21-34390476,Email:sales@cwtc.com.pk MultanAddress:3CooperativeBankBuilding,ChowqKutchery,Multan,Pakistan. Website:www.cwtc.com.pk

[close]

Comments

no comments yet