Built With Quality In Mind 2017 Industrial Analyzers Product Catalog www.E-Inst.com (215) 750-1212

[close]

p. 2

E1500 Multipurpose Tool for Maintenance & Tuning of Boilers, Engines, Furnaces, and Other Combustion Applications Industrial Combustion Gas Analyzer Accurate Reliable CO2 CO NEW! Robust O2 Combustion Efficiency Fast CO Sensor w/ NOx Filter Draft & Differential Pressure 2 Channel Thermometer Internal Memory (2000 Tests) Zoom Feature Pre-Calibrated, Field Replaceable Gas Sensors Built with Quality in Mind PC Software with Automatic Data Saving Full COLOR Graphic Display BUILT-IN Printer E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 3

E1500 Features BUILT-IN Printer Pre-Calibrated Field Replaceable Sensors Magnetic Rubber Holster Full COLOR Graphic Display Simple Menu Interface Unbreakable Metal Connections PC Software Package with Bluetooth & USB Parameter O₂ CO H₂ Compensated w/ Built-In NOx Filter CO₂ Tair Tgas Differential Temp. Pressure/Draft Excess Air Efficiency Sensor Electrochemical Electrochemical Calculated Pt100 Tc K Calculated Semiconductor Calculated Calculated Range 0 - 25 % Resolution 0.1 % 0 - 8000 ppm 1 ppm 0 - 99.9% 0.1 % -10 to 212 ˚F 0.1 ˚F -10 to 1830 ˚F 0.1 ˚F -10 to 1830 ˚F 0.1 ˚F ±0 - 80 inH₂O 0.001 in H₂O 0 - 850% 0 - 100% 1% 0.1 % Accuracy ±0.2 % vol ±8 ppm <400 ppm ±5 % rdg up to 2000 ppm ±10 % rdg for >2000 ppm ±1 ˚F ±2 ˚F ±1 % of rdg. Ordering Information Model No. Description E1500-1 E1500 Unit (O2 & CO Gas Sensors, CO2 Calculated, Efficiency, Excess Air, Draft, Pressure, Temperature, Rechargeable Battery & AC Plug, Gas Sample Probe with Hose, Vinyl Carrying Case, Calibration Certificate, Water Trap, 2000 Test Memory, Built-In Printer, & PC Software Package Built with Quality in Mind NEW! Probes & Hoses Standard: 12”, 300mm Probe, 1470˚F/800˚C max with 10’/3m Dual Hose Long: 30”, 750mm Probe, 1470˚F/800˚C max with 10’/3m Dual Hose Long & High Temp: 40”, 1m Probe, 2190˚F/1200˚C max, with 10’/3m Hose Hose Extensions: 10’/3m Length Available All E1500 Include: • Built-In Printer • Draft & Differential Pressure • Temperature Measurements • Calculation for CO₂, Efficiency & Excess Air • Rechargeable Batteries & AC Charger • Gas Sampling Probe & Hoses • Water Trap with Filter Cartridge • Magnetic Rubber Holster • 2000 Test Internal Memory • PC Software & USB Cable • Bluetooth Module (Internal) • Operating Manual • Calibration Certificate • Vinyl Carrying Case Bulletin: E1500.2 Ed. 01/2017 Information & design subject to change at manufacture’s discretion E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 4

E4500 Handheld Versatile Gas Analyzer for Emissions Monitoring of Boiler, Engine, Furnace, and Other Combustion Applications Built with Quality in Mind Industrial Combustion Gas & Emissions Analyzer Accurate Reliable CO2 NEW!SampFloerCLoonwdNitiOoxni&ngSUOn2 it CO Up To FOUR Gas Sensors Robust PC Software with Bluetooth Fast O2 Automatic Data Saving Total NOx Capable Combustion Efficiency NO CO Sensor w/ NOx Filter Draft & Differential Pressure 2 Channel Thermometer Internal Memory (2000 Tests) Customizable Display Screen & Print-Out NOx NO2 SO2 CxHy (HC) Pre-Calibrated, Field Replaceable Gas Sensors Dilution Pump For CO Auto-Range Measurements Up To 10% NEW Sample Conditioning Unit For Low NOx & Low SO2 Applications Full COLOR Graphic Display BUILT-IN Printer E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 5

E4500 Features Sample Conditioning Unit For Low NOx & SO₂ Applications Removes Moisture at the Probe For More Accurate Low NOx & SO2 Measurements Built with Quality in Mind High Temperature Probe & Sintered Filter Available Parameter O₂ CO H₂ Compensated w/ Built-In NOx Filter CO DILUTED CO₂ NO NO₂ Low NO and/or Low NO₂ Sensor Electrochemical Electrochemical Electrochemical Calculated Electrochemical Electrochemical Electrochemical Range 0 - 25 % 0 - 8000 ppm Resolution 0.1 % 1 ppm 0.8% - 10.00% 0.01% 0 - 99.9% 0 - 5000 ppm 0.1 % 1 ppm 0 - 1000 ppm 1 ppm 0 - 100.0 ppm 0.1 ppm Accuracy ±0.2 % vol ±8 ppm (0 - 200ppm) ±5 % rdg (201 - 2000ppm) ±10 % rdg (2001 - 8000ppm) ±10% rdg ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 5000ppm) ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 1000ppm) ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) Probes & Hoses Standard: 12”, 300mm Probe, 1470˚F/800˚C max with 10’/3m Dual Hose Long: 30”, 750mm Probe, 1470˚F/800˚C max with 10’/3m Dual Hose Long & High Temp: 40”, 1m Probe, 2190˚F/1200˚C max, with 10’/3m Hose Hose Extensions: 10’/3m Length Available NOx SO₂ Low SO₂ Calculated Electrochemical 0 - 5000 ppm 0 - 5000 ppm 1 ppm 1 ppm Electrochemical 0 - 100.0 ppm 0.1 ppm ±5 ppm (0 - 100ppm) ±5% rdg (101 - 5000ppm) ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) CxHy (HC) Pellistor 0 - 5% 0.01% ±5% Full Scale Tair Tgas Pressure/Draft Pt100 Tc K Semiconductor -10 to 212 ˚F -10 to 100 ˚C 0.1 ˚F 0.1 ˚C -4 to 2280 ˚F 0.1 ˚F -20 to 1250 ˚C 0.1 ˚C ±0 - 80 inH₂O 0.001 inH₂O ±1 ˚F ±1 ˚C ±0.5 ˚C (-20 to 100 ˚C) ±0.5% rdg (101 to 1250 ˚C) ±1.0% rdg Excess Air Efficiency Calculated Calculated 0 - 850% 0 - 100% 1% 0.1 % Ordering Information Model No. Description E4500-3 E4500 with O₂, CO, NO/NOx Gas Sensors Installed, Upgradeable to 4th Gas Sensor E4500-N E4500 with O₂, CO, NO/NOx, NO₂ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm E4500-NLow E4500 with O₂, CO, Low NO/NOx, Low NO₂ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm E4500-S E4500 with O₂, CO, NO/NOx, SO₂ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm E4500-SLow E4500 with O₂, CO, NO/NOx, Low SO₂ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm E4500-C E4500 with O₂, CO, NO/NOx, CxHy (HC) Gas Sensors & CO Dilution Auto-Range to 50,000 ppm All E4500 Kits Include: • Built-In Printer • Draft & Differential Pressure • Temperature Measurements • Calculation for CO₂, Efficiency & Excess Air • Rechargeable Batteries & AC Charger • Gas Sampling Probe & Hoses • Water Trap with Filter Cartridge • Magnetic Rubber Holster • 2000 Test Internal Memory • PC Software & USB Cable • Bluetooth Module (Internal) • Operating Manual • Calibration Certificate • ABS Hard Plastic Carrying Case E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 Bulletin: E4500.3 Ed. 01/2017 Information & design subject to change at manufacture’s discretion

[close]

p. 6

E6000 Hand-Held Versatile Gas Analyzer for Emissions Monitoring of Boiler, Engine, Furnace, and Other Combustion Applications Six Gas Industrial Emissions Analyzer Accurate Reliable CO2 NEW!SampFloerCLoonwdNitiOoxni&ngSUOn2 it CO Up To SIX Gas Sensors Robust PC Software with Bluetooth Fast O2 Automatic Data Saving Total NOx Capable Low NOx & Low SO₂ Capable CO Sensor w/ NOx Filter Draft & Differential Pressure Combustion Efficiency Internal Memory (2000 Tests) Customizable Display Screen & Print-Out Pre-Calibrated, Field Replaceable Gas Sensors Dilution Pump For CO Auto-Range Measurements Up To 10% Built with Quality in Mind NO NOx NO₂ SO₂ CxHy (HC) H₂S NEW Sample Conditioning Unit For Low NOx & Low SO₂ Applications Full COLOR Graphic Display BUILT-IN Printer E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 7

E6000 Features Sample Conditioning Unit For Low NOx & SO₂ Applications Removes Moisture at the Probe For More Accurate Low NOx & SO2 Measurements Built with Quality in Mind High Temperature Probe & Sintered Filter Available Parameter O₂ Sensor Range Electrochemical 0 - 25 % Resolution Accuracy 0.1 % ±0.2 % vol Probes & Hoses CO H₂ Compensated w/ Built-In NOx Filter CO DILUTED CO₂ NO Electrochemical Electrochemical Calculated Electrochemical 0 - 8000 ppm 1 ppm 0.8% - 10.00% 0.01% 0 - 99.9% 0 - 5000 ppm 0.1 % 1 ppm NO₂ Electrochemical 0 - 1000 ppm 1 ppm Low NO and/or Low NO₂ Electrochemical 0 - 100.0 ppm 0.1 ppm ±8 ppm (0 - 200ppm) ±5 % rdg (201 - 2000ppm) ±10 % rdg (2001 - 8000ppm) ±10% rdg ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 5000ppm) ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 1000ppm) ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) Standard: 12”, 300mm Probe, 1470˚F/800˚C max with 10’/3m Dual Hose Long: 30”, 750mm Probe, 1470˚F/800˚C max with 10’/3m Dual Hose Long & High Temp: 40”, 1m Probe, 2190˚F/1200˚C max, with 10’/3m Hose Hose Extensions: 10’/3m Length Available NOx SO₂ Low SO₂ Calculated Electrochemical 0 - 5000 ppm 0 - 5000 ppm 1 ppm 1 ppm Electrochemical 0 - 100.0 ppm 0.1 ppm ±5 ppm (0 - 100ppm) ±5% rdg (101 - 5000ppm) ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) CxHy (HC) Pellistor 0 - 5% 0.01% ±5% Full Scale H₂S Tair Tgas Electrochemical 0 - 500 ppm 0.1 ppm Pt100 Tc K -10 to 212 ˚F -10 to 100 ˚C -4 to 2280 ˚F -20 to 1250 ˚C 0.1 ˚F 0.1 ˚C 0.1 ˚F 0.1 ˚C ±5 ppm (0.0 - 125.0ppm) ±4% rdg (125.1 - 500.0ppm) ±1 ˚F ±1 ˚C ±0.5 ˚C (-20 to 100 ˚C) ±0.5% rdg (101 to 1250 ˚C) Pressure/Draft Semiconductor ±0 - 80 inH₂O 0.001 inH₂O ±1.0% rdg Excess Air Calculated 0 - 850% 1% Efficiency Calculated 0 - 100% 0.1 % Ordering Information Model No. Description E6000-5DS E6000 with O₂, CO, NO, NO₂ , SO₂ Gas Sensors Installed, Upgradeable to 6th Gas Sensor* E6000-5DC E6000 with O₂, CO, NO, NO₂, CxHy(HC) Gas Sensors Installed, Upgradeable to 6th Gas Sensor* E6000-5SC E6000 with O₂, CO, NO, SO₂, CxHy(HC) Gas Sensors Installed, Upgradeable to 6th Gas Sensor* E6000-5SH E6000 with O₂, CO, NO, SO₂, H₂S Gas Sensors Installed, Upgradeable to 6th Gas Sensor* E6000-6DSH E6000 with O₂, CO, NO, NO₂, SO₂, H₂S Gas Sensors Installed* E6000-6DSC E6000 with O₂, CO, NO, NO₂, SO₂, CxHy(HC) Gas Sensors Installed* *All Configurations Available With Low NO, Low NO₂, and/or Low SO₂ Sensors All E6000 Kits Include: • Built-In Printer • CO Dilution Auto-Range to 10% • Draft & Differential Pressure • Temperature Measurements • Calculation for CO₂, Efficiency & Excess Air • Rechargeable Batteries & AC Charger • Gas Sampling Probe & Hoses • Water Trap with Filter Cartridge • Magnetic Rubber Holster • 2000 Test Internal Memory • PC Software & USB Cable • Bluetooth Module (Internal) • Operating Manual • Calibration Certificate • ABS Hard Plastic Carrying Case • Android Smart Phone App E Instruments International www.E-Inst.com Bulletin: E6000.2 Ed. 01/2017 Information & design subject to change at manufacture’s discretion P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 8

E8500 PLUS Complete Portable Emissions Analyzer with up to Nine Gas Sensors for Boiler, Engine, Furnace, and other Combustion Applications Built with Quality in Mind Portable Industrial Flue Gas & Emissions Analyzer CO₂(NDIR) NO₂ Up to 9 Total Gas Sensors NEW Software with Automatic Data Logging CxHy(HC) NO Built-In Thermoelectric Chiller SO₂ CO Automatic Condensate Drain NEW Display Screen & Keypad NEW!SaFmoprlLeoCwonNdOitxio&niSnOg2Unit H₂S O₂ Upgraded Memory (2000 Tests) VOC Direct CO₂ Measurement to 50% CO Dilution Auto-Range Long Life Rechargeable Battery True NOx & Low NOx Measurements True SO₂ & Low SO₂ Measurements Backlit Display with Zoom Function High Accuracy NDIR Sensors MADE IN USA REAL-TIME Software Package with Automatic Data Logging NEW Display Screen & Keypad Design with Easy Filter Replacement NEW PID VOC Sensor Option E Instruments International www.E-Inst.com P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047

[close]

p. 9

E8500 PLUS Real-Time Software with Data Logging The updated “EGAS” software package includes the ability to save & graph data in real-time in the field with a laptop or in a laboratory with a PC. It also allows the user to automatically log data for an exact number of tests for a specified time period. Communications between the E8500 PLUS and a computer are established either by wireless Bluetooth communications or USB cable. A Bluetooth wireless adapter for a computer comes standard with each E8500 PLUS gas analyzer. Data from the “EGAS” software can be exported to other spreadsheet programs for more user flexibility to create detailed emissions reports. Built with Quality in Mind EGAS Software 60” High Temperature Probe Sintered Filter Long & High Temperature Probes with Sintered Filter The internal thermoelectric chiller efficiently and quickly removes the water vapor from the flue gas sample to prevent combustion gases from bubbling from the gas phase into the condensate. The built-in condensate drain pump automatically pumps the accumulated water out through the bottom of the unit for greater convenience. E Instruments International www.E-Inst.com P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047

[close]

p. 10

E8500 PLUS Specifica�ons Parameter Sensor O2 Electrochemical CO Electrochemical CO Auto Range CO NO Low NO NO2 Low NO2 NOx SO2 Low SO2 CO2 CO2 Electrochemical NDIR Electrochemical Electrochemical Electrochemical Electrochemical Calculated Electrochemical Electrochemical Calculated NDIR Range 0 - 25% 0 - 8000 ppm Res. 0.01% 1 ppm 0 - 20,000 ppm 1 ppm Accuracy ±0.1% vol <300 ppm=±8 ppm up to 2000 ppm=±4% >2000 ppm=±10% ±10% rdg. 0 - 15.00% 0 - 5000 ppm 0 - 100.0 ppm 0 - 1000 ppm 0 - 100.0 ppm 0 - 5000 ppm 0 - 5000 ppm 0 - 100.0 ppm 0 - 99.9% 0 - 50.0% 0.01% 1 ppm 0.1 ppm 1 ppm 0.1 ppm 1 ppm 1 ppm 0.1 ppm 0.1% 0.1% ±3% rdg. <125 ppm=±5 ppm up to 5000 ppm=±4% <50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% <125 ppm=±5 ppm up to 1000 ppm=±4% <50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% <125 ppm=±5 ppm up to 5000 ppm=±4% <50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% ±3% rdg. < 20% ±5% rdg. > 20% CxHy NDIR H2S VOC Tair Electrochemical PID Pt100 Tgas Tc K ∆T Pressure/Draft Excess Air Gas Velocity Efficiency Calculated Bridge Calculated Calculated Calculated 0 - 3.00% 0 - 500 ppm 0 - 200 ppm -10 - 99.9°C 14.0 - 212.0°F 0 - 999.9°C 32.0 - 1830°F 0 - 999.9°C 32.0 - 1830°F ± 40.0 in H2O 1.00 - infinity 0 - 99.9 m/s 0 - 330 ft/s 1 - 99.9% 0.01% ±3% rdg. + 0.01% 1 ppm <125 ppm=±5 ppm up to 500 ppm=±4% 1 ppm ±10 % rdg. + 1 ppm 1°C ±2°C 1°F ±3°F 0.1°C 0.1°F ±3°C ±5°F 1°C 1°F 0.1 in H2O 0.01 ±1% rdg. 0.1 m/s 0.1 ft/s 0.1% Gas Sensors The E8500 PLUS can have a maximum of nine total gas sensors; up to six electrochemical type sensors, up to three NDIR type sensors, and an optional PID sensor for measuring VOC. Easy Filter Replacement The E8500 PLUS has a newly designed user interface that includes an easily accessible filter compartment for quick and simple inspection & replacement of filters in the field. Built with Quality in Mind Draft, Pressure, & Velocity An internal pressure sensor allows the analyzer to measure both pressure and stack draft. With two pressure inputs, differential pressure can also be measured. Gas velocity can be measured using the differential pressure and an optional Pitot tube. Sample Conditioning Unit The Sample Conditioning Unit is mounted directly at the sampling probe exit, where excess moisture rapidly condenses and separates from the gas sample. This minimizes contact of the gases with moisture, which could potentially affect NOx and SO2 measurements. E Instruments International www.E-Inst.com P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047

[close]

p. 11

E8500 PLUS E8500 PLUS Ordering Code Built with Quality in Mind Part # 8500P - Table A - Table B - Table C Table A - Electrochemical Sensors O O2 Sensor (0 - 25 %) C CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 20,000 ppm N NO Sensor (0 - 5000 ppm) D NO2 Sensor (0 - 1000 ppm) S SO2 Sensor (0 - 5000 ppm) H H2S Sensor (0 - 500 ppm) V VOC Sensor (0 - 200 ppm)** *H2S & VOC sensors cannot concurrently be installed on one E8500 PLUS **Must include NDIR sensor option to include VOC sensor Table B - NDIR (non-dispersive infrared) Sensors ABC CO2 Sensor (0 - 50 %), CxHy Sensor (0 - 3 %), and High CO Sensor (0 - 15 %) 0 No NDIR sensors Table C - Sampling Probes and Hoses 12 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 30 30” (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 40 40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications 60 60” (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications Standard E8500 PLUS Configuration (E8500P-OCN-0-12) Includes: - O2, CO, and NO Gas Sensors - Thermoelectric Chiller with Automatic Condensate Drain Pump - Rechargeable Battery Pack - 110-240VAC/50-60Hz Battery Charger - 12”/300mm Probe with 10’/3m Dual Hose - Stack Gas & Air Temperature Measurements - Draft & Differential Pressure Measurements - Calculated Values for Efficiency, Excess Air, & CO2% - Internal Memory (2,000 Tests) - Real-Time Software Package with Bluetooth Module - Wireless Bluetooth Communications - Protective Carrying Case - Calibration Certificate - Operations Manual Weight: 11 lbs. (5 kg) Dimensions: 10x6x9.5” (26x15x24 cm) Bulletin: E8500PLUS.2 Ed. 01/2017 Information & design subject to change at the manufacturer’s discretion E Instruments International www.E-Inst.com P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047

[close]

p. 12

E8500 Cooled NOx Portable Emissions Analyzer with Temperature Controlled NOx Measurement for Boiler, Engine, Furnace, and other Combustion Applications Built with Quality in Mind Portable Industrial Flue Gas & Emissions Analyzer NEW Cooled NO Sensor to Optimize Accuracy of NOx Measurements MADE IN USA Displays & Records the Temperature at the Cooled NO Sensor NO(Cooled) CO₂(NDIR) NO₂ CxHy SO₂ CO H₂S VOC O₂ NOx Up to 9 Total Gas Sensors Built-In Thermoelectric Cooler for NO Sensor NEW Software with Automatic Data Logging NEW Display Screen & Keypad NEW PID VOC Sensor Option Upgraded Memory (2000 Tests) Direct CO₂ Measurement to 50% CO Dilution Auto-Range Long Life Rechargeable Battery True NOx & Low NOx Measurements E Instruments International www.E-Inst.com P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047

[close]

p. 13

E8500 Cooled NOx Built with Quality in Mind Cooled NO Sensor for Optimal Accuracy The accuracy of the gas sensor for NO, the primary component of NOx, can be compromised when exposed to ambient temperatures above 86°F (30°C) and significantly more so above 104°F (40°C). To help prevent this temperature effect on the NO sensor, the E8500 Cooled NOx keeps the NO sensor cooled with an internal cooling system. The analyzer measures, displays, & records the NO sensor temperature to make it easier to comply with US EPA conditional test methods such as CTM-030. 40”(1m) & 60”(1.5m) High Temperature Probes Sintered Filter EGAS Software Real-Time Software with Data Logging The updated “EGAS” software package includes the ability to save & graph data in real-time in the field with a laptop or in a laboratory with a PC. It also allows the user to automatically log data for an exact number of tests for a specified time period. Communications between the E8500 Cooled NOx and a computer are established either by wireless Bluetooth communications or USB cable. A Bluetooth wireless adapter for a computer comes standard with each E8500 Cooled NOx gas analyzer. Data from the “EGAS” software can be exported to other spreadsheet programs for more user flexibility to create detailed emissions reports. E Instruments International www.E-Inst.com P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047

[close]

p. 14

E8500 Cooled NOx Specifica�ons Parameter Sensor O2 Electrochemical CO Electrochemical CO Auto Range CO NO Low NO NO2 Low NO2 NOx SO2 Low SO2 CO2 CO2 Electrochemical NDIR Electrochemical Electrochemical Electrochemical Electrochemical Calculated Electrochemical Electrochemical Calculated NDIR Range 0 - 25% 0 - 8000 ppm Res. 0.01% 1 ppm 0 - 20,000 ppm 1 ppm Accuracy ±0.1% vol <300 ppm=±8 ppm up to 2000 ppm=±4% >2000 ppm=±10% ±10% rdg. 0 - 15.00% 0 - 5000 ppm 0 - 100.0 ppm 0 - 1000 ppm 0 - 100.0 ppm 0 - 5000 ppm 0 - 5000 ppm 0 - 100.0 ppm 0 - 99.9% 0 - 50.0% 0.01% 1 ppm 0.1 ppm 1 ppm 0.1 ppm 1 ppm 1 ppm 0.1 ppm 0.1% 0.1% ±3% rdg. <125 ppm=±5 ppm up to 5000 ppm=±4% <50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% <125 ppm=±5 ppm up to 1000 ppm=±4% <50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% <125 ppm=±5 ppm up to 5000 ppm=±4% <50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% ±3% rdg. < 20% ±5% rdg. > 20% CxHy NDIR H2S VOC Tair Electrochemical PID Pt100 Tgas Tc K ∆T Pressure/Draft Excess Air Gas Velocity Efficiency Calculated Bridge Calculated Calculated Calculated 0 - 3.00% 0 - 500 ppm 0 - 200 ppm -10 - 99.9°C 14.0 - 212.0°F 0 - 999.9°C 32.0 - 1830°F 0 - 999.9°C 32.0 - 1830°F ± 40.0 in H2O 1.00 - infinity 0 - 99.9 m/s 0 - 330 ft/s 1 - 99.9% 0.01% ±3% rdg. + 0.01% 1 ppm <125 ppm=±5 ppm up to 500 ppm=±4% 1 ppm ±10 % rdg. + 1 ppm 1°C ±2°C 1°F ±3°F 0.1°C 0.1°F ±3°C ±5°F 1°C 1°F 0.1 in H2O 0.01 ±1% rdg. 0.1 m/s 0.1 ft/s 0.1% Gas Sensors The E8500 Cooled NOx can have a maximum of nine total gas sensors; up to six electrochemical type sensors, up to three NDIR type sensors, and an optional PID sensor for measuring VOC. Easy Filter Replacement The E8500 Cooled NOx has a newly designed user interface that includes an easily accessible filter compartment for quick and easy inspection & replacement of filters in the field. Built with Quality in Mind Draft, Pressure, & Velocity An internal pressure sensor allows the analyzer to measure both pressure and stack draft. With two pressure inputs, differential pressure can also be measured. Gas velocity can be measured using the differential pressure and an optional Pitot tube. Sample Conditioning Unit The Sample Conditioning Unit is mounted directly at the sampling probe exit, where excess moisture rapidly condenses and separates from the gas sample. This minimizes contact of the gases with moisture, which could potentially affect NOx and SO2 measurements. E Instruments International www.E-Inst.com P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047

[close]

p. 15

E8500 Cooled NOx E8500 Cooled NOx Ordering Code Part # 8500CN - Table A - Table B - Table C Built with Quality in Mind Table A - Electrochemical Sensors O O2 Sensor (0 - 25 %) C CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 20,000 ppm N NO Sensor (0 - 5000 ppm) NL Low NO Sensor (0 - 100.0 ppm) D NO2 Sensor (0 - 1000 ppm) DL Low NO2 Sensor (0 - 100.0 ppm) S SO2 Sensor (0 - 5000 ppm) H H2S Sensor (0 - 500 ppm) V VOC Sensor (0 - 200 ppm)** *H2S & VOC sensors cannot concurrently be installed on one E8500 Cooled NOx **Must include NDIR sensor option to include VOC sensor Table B - NDIR (non-dispersive infrared) Sensors ABC CO2 Sensor (0 - 50 %), CxHy Sensor (0 - 3 %), and High CO Sensor (0 - 15 %) 0 No NDIR sensors Table C - Sampling Probes and Hoses 12 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 30 30” (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 40 40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications 60 60” (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications Bulletin: E8500CooledNOx.1 Ed. 03/2017 Information & design subject to change at the manufacturer’s discretion Standard E8500 Cooled NOx Configuration (E8500CN-OCN-0-12) Includes: - O2, CO, and NO Gas Sensors - Thermoelectric Cooler for NO Sensor - External Water Trap with Filter - Sample Conditioning Unit - Rechargeable Battery Pack - 110-240VAC/50-60Hz Battery Charger - 12”/300mm Probe with 10’/3m Dual Hose - Stack Gas & Air Temperature Measurements - NO Sensor Temperature Measurement - Draft & Differential Pressure Measurements - Calculated Values for Efficiency, Excess Air, & CO2% - Internal Memory (2,000 Tests) - Real-Time Software Package with Bluetooth Module - Wireless Bluetooth Communications - Protective Carrying Case - Calibration Certificate Weight: 11 lbs. (5 kg) Dimensions: 10x6x9.5” (26x15x24 cm) - Operations Manual E Instruments International www.E-Inst.com P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047