Built With Quality In Mind IAQ Product Catalog www.E-Inst.com P: (215) 750-1212 F: (215) 750-1399 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047

[close]

p. 2

AQ Comfort Handheld Indoor Air Quality Monitor The Latest in Indoor Air Quality Monitoring & Real-Time Data-Logging for IAQ Analysis in Homes, Schools, Offices, and much more Innovative IAQ Tool for HVAC Professionals Provide your own Comfort Audit ™ REAL-TIME Continuous Data-Logging Active Internal Sampling Pump Compact Handheld Unit Easy to Use Menu System Large Internal Memory (2000) Long Lasting Rechargeable Battery MADE IN USA Accessories: PC Software & USB Cable Protective Magnetic Rubber Boot Optional Wireless Printer Optional Handheld Probe “Built with Quality in Mind” Real-Time Data-Logging for Graphs, Data Review, IAQ Reports Wireless Communications with Computer & Remote Printer Light Weight, Durable, Handheld Design CO 2 % RH Dew Point Wet Bulb Temp. Differential Temp. Differential Pressure Add SafetyCO E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 3

AQ Comfort Specifications Parameter Sensor CO2 NDIR CO Electrochemical Relative Humidity TAemmpb.ient Temperature TFC Pt100 Differential Pressure Bridge Temperature Type K T1 Tc K Electomagnetic Compatibility Range 0 - 5,000 ppm 0 - 200 ppm 5 - 95% -40 - 257°F (-40 - 125°C) ± 8.0 inH2O (±20.0 mbar) 0 - 2000°F (0 - 1100°C) Res. 1 ppm 0.1 ppm 0.1% 0.1°C/F Accuracy ± 2% rdg. ± 10 ppm ± 1% rdg. ± 0.2 ppm ± 2% RH ± 0.4°C (0 - 60°C) 0.1 inH2O (0.25 mbar) ± 1% rdg. 1°C/F 5°F (3°C) or 2% of rdg EN 61326-1, Portable Equipment Applications Features ALL AQ Comfort Kits Include: ● Continuous Active Internal Sampling Pump ● Differential Pressure ● Differential Temperature ● Operating Manual ● Long Lasting Battery & AC Charger ● Factory Calibration Certificate AQ Comfort ORDERING CODE AQ Comfort Kit CO 2 CO Ambient Temp Kit-1 ■ Kit-2 ■ ■ Kit-3 ■ ■ Kit-4 ■ ■ ■ %RH, Wet Bulb & Dew Point ■■ Bluetooth ■■ Internal Memory (2000) ■■■■ PC Software Kit Carrying Case ■ ■■ Temp CO2 ∆P CO % RH (Optional) AQ Gas® Real-time Datalogging Software Distributed By: Bulletin: AQCOMFORT.1 Ed. 10/2016 Information & design subject to change at th’e manufacture’s discretion. E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 4

AQ INCUBA The Latest in Incubator Monitoring & Real-Time Data-Logging for Air Quality Analysis for Incubators CO₂ Incubator Monitor Built with Quality in Mind Accurate Reliable Temp. CO2 Measurement Ranges of: (0 - 5%, 0 - 10%, 0 - 20%) CO₂ Relative Humidity & Temperature Barometric Pressure Fast %RH REAL-TIME Data-Logging Active Internal Sampling Pump User Friendly Interface Large Internal Memory (2000) Long Lasting Rechargeable Battery Protective Magnetic Hands-Free Boot MADE IN USA Accessories: Real-Time PC Software Optional Wireless Printer Optional Temperature Probe Wireless Communications with Computer & Remote Printer Real-Time Data-Logging for Graphs, Data Review, & IAQ Reports Light Weight, Durable, Hand-Held Design E Instruments International www.E-Inst.com P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047

[close]

p. 5

AQ INCUBA Specifications Parameter Sensor CO2 NDIR Relative Humidity Ambient Temperature TFC Pt100 Barometric Pressure Solid State Temperature Type K T1 Tc K O2 Electrochemical Electomagnetic Compatibility Features Range 0 - 5% 0 - 10% 0 - 20% Res. 0.1% 0.1% 0.1% Accuracy ± 3% of rdg. ± 3% of rdg. ± 3% of rdg. 5 - 95% RH 0.1% RH ± 2% RH -40 - 257°F (-40 - 125°C) 0.1°C/F ± 0.4°C (0 - 60°C) 260 - 1260 mbar 1 mbar ± 2 mbar 0 - 2000°F (0 - 1100°C) 0 - 25% 1°C/F 0.1% 5°F (3°C) or 2% of rdg ± 0.1% vol rdg. EN 61326-1, Portable Equipment ALL AQ INCUBA Kits Include: ● CO2 Measurement ● Barometric Pressure ● Moisture Removal System ● Continuous Active Internal Sampling Pump ● Sampling Hose ● Differential Temperature ● Operating Manual ● Long Lasting Battery & AC Charger ● Factory Calibration Certificate AQ INCUBA ORDERING CODE AQ INCUBA Kit 100 101 102 CO 2 % Relative Humidity 0 - 5% 0 - 10% 0 - 20% Ambient Temp Barometric Pressure O2 (0 - 25%) Option Option Option Optional Accessories Applications CO2 Temp % RH P. Bar O2 AQ Gas® Real-time Datalogging Software Bulletin: AQINCUBA.1 Ed. 02/2017 Information & design subject to change at the ’manufacture’s discretion. Wireless Bluetooth™ Printer (EE900P) Temperature Probe (E1500SP) Moisture Exchange Tube (AQMET) E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 6

AQ PRO Handheld Indoor Air Quality Monitor The Latest in Indoor Air Quality Monitoring & Real-Time Data-Logging for IAQ Analysis in Hospitals, Universities, Labs, Airports, and more Customize UP to 3 Gases (Multiple Parameters - Up to 6 Total) REAL-TIME Continuous Data-Logging Active Internal Sampling Pump Compact Handheld Unit PC Software & USB Included Large Internal Memory (2000) Long Lasting Rechargeable Battery Barometric Air Pressure Protective Magnetic Rubber Boot Optional Wireless Printer Optional Handheld Probe MADE IN USA “Built with Quality in Mind” Real-Time Data-Logging for Graphs, Data Review, IAQ reports Wireless Communications with Computer & Remote Printer Light Weight, Durable, Handheld Design % RH Temp Barometric Pressure CO 2 CO Formaldehyde NO2 SO2 H2S O 2 NO E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 7

AQ PRO Specifications Parameter Sensor Relative Humidity TFC Ambient Temp. Pt100 Barometric Pressure Solid State Differential Pressure Bridge Range 5 - 95% RH -40 - 257°F (-40 - 125°C) 260 - 1260 mbar Res. 0.1% RH 0.1°C/F 1 mbar Accuracy ± 2% RH ± 0.4°C (0 - 60°C) ± 2 mbar ± 8.0 inH2O (±20.0 mbar) 0.1 inH2O (0.25 mbar) ± 1% of rdg. Temperature Type K T1 Tc K 0 - 2000°F (0 - 1100°C) 1°C/F Air Velocity Calculated Electomagnetic Compatibility 0 - 300 ft/sec 1 ft/sec EN 61326-1, Portable Equipment AQ PRO ORDERING CODE ± 2% of rdg Part #: PRO - ___ - ___ - ___ Example: Part #: PRO - C2 - C - H = CO2, CO, & H2S ALL AQ PRO Kits Include: Temperature, % Relative Humidity Barometric Pressure PC Software & USB Cable REAL-TIME Continuous Data-Logging Bluetooth Connectivity Protective Carrying Case Continuous Active Internal Sampling Pump Differential Pressure Operating Manual & Quick Reference Guide Long Lasting Battery & AC Charger Factory Calibration Certificate CH2O CO2 Select UP to ANY 3* Gases Below: Parameter Sensor Range C2 - Carbon Dioxide (CO2)1 NDIR 0 - 5,000 ppm C - Carbon Monoxide (CO)1 EC2,5 0 - 200 ppm Res. 1 ppm 0.1 ppm Accuracy ± 2% of rdg. ± 10 ppm ± 4% of rdg. ± 0.5 ppm F - Formaldehyde (CH2O)3,4 EC2,5 0 - 10 ppm ( 0 - 10,000 ppb) 1 ppb ± 5% of rdg. ± 50 ppb H - Hydrogen Sulfide (H2S)1 EC 2,5 0 - 100 ppm 1 ppm ±4% of rdg. ± 0.5 ppm N - Nitrogen Dioxide (NO2)1 EC2,5 O - Oxygen (O ) 2 - Sulfur Dioxide (SO2)1 EC 2,5 EC 2,5 X - Nitric Oxide (NO)1 EC 2,5 0 - 20 ppm 0 - 25% 0 - 20 ppm 0 - 250 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm 0.1 % ± 0.1% vol rdg. 0.1 ppm ± 4% of rdg. ± 0.5 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm 1. Other Ranges are Available Upon Request 2. Electrochemical 3. Accuracy Based on Laboratory Conditions 4. This sensor may have interference from H , CO, H S and other reducing gases such as alcohols *5.Maximum of TWO (2) Electrochemical (EC) Sensors Per Unit Optional Accessories NO2 O2 SO2 CO % RH H2S AQ Gas® Real-Time Datalogging Software Distributed By: Bulletin: AQPRO.5 Ed. 01/2017 Information & design subject to change at the man’ufacture’s discretion. Wireless Bluetooth™ Printer (EE900P) Sampling Probe (E85AACSF13) Moisture Exchange Tube for Calibration (AQMET) Pitot Tube for Air Velocity (BB610032) E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 8

AQ VOC Portable Handheld VOC Monitor Accurate VOC Monitoring & Real-Time Data-Logging for Air Quality Analysis in Industrial Safety, Environmental, Laboratories and other IAQ Applications Dynamic PID VOC Sensor Technology 0 - 20,000 PPB 0 - 200 PPM VOC in ppb/µg/m³ or ppm/mg/m³ UPGRADEABLE: (Add UP TO 2 More Gas Sensors) REAL-TIME Continuous Data-Logging Active Internal Sampling Pump Large Internal Memory (2000) PC Software & USB Included Long Lasting Rechargeable Battery Barometric Air Pressure Protective Magnetic Rubber Boot Optional Wireless Printer Optional Handheld Probe MADE IN USA “Built with Quality in Mind” Real-time Data-Logging Software for Graphs, Data Review, IAQ reports Wireless Communications with Computer & Remote Printer Light Weight, Durable, Handheld Design VOC % RH Temp Barometric Pressure Formaldehyde CO 2 O 2 CO NO2 H2S SO2 NO E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 9

AQ VOC Specifications Parameter Low Range VOC OR High Range VOC Sensor PID PID Relative Humidity TFC Ambient Temp. Pt100 Barometric Pressure Solid State Differential Pressure Bridge Air Velocity Calculated Electomagnetic Compatibility Range 0 - 20,000 ppb (0 - 46,000 µg/m3) 0 - 200 ppm (0 - 460 mg/m3) 5 - 95% RH Res. 1 ppb (1 µg/m3) 1 ppm (1 mg/m3) 0.1% RH Accuracy ±10 % of rdg. ± 20 ppb ±10 % of rdg. ± 2 ppm ± 2% RH -40 - 257°F (-40 - 125°C) 0.1°C/F ± 0.4°C (0 - 60°C) 260 - 1260 mbar 1 mbar ± 2 mbar ± 8.0 in H2O (±20 mbar) 0.1 inH2O (0.25 mbar) 0 - 300 ft/sec 1 ft/sec EN 61326-1, Portable Equipment ±1% of rdg. AQ VOC ORDERING CODE Part #: VOC- ___ - ___ - ___ Example: Part #: VOC - 1 - F - C2 = Low Range VOC, CH2O, CO2 ALL AQ VOC Kits Include: Temperature, % Relative Humidity Barometric Pressure PC Software & USB Cable REAL-TIME Continuous Data-Logging CO2 Bluetooth Connectivity Protective Carrying Case Continuous Active Internal Sampling Pump Operating Manual & Quick Reference Guide Long Lasting Battery & AC Charger CH2O Factory Calibration Certificate Select Your VOC Range: Parameter Sensor Range V1 - Low Range VOC PID 0 - 20,000 ppb (0 - 46,000 µg/m3) V2 - High Range VOC PID 0 - 200 ppm (0 - 460 mg/m3) Optional Gas Sensor Upgrades (Choose UP To ANY 2) C2 - Carbon Dioxide (CO2)1 NDIR C - Carbon Monoxide (CO)1 EC 2 0 - 5,000 ppm 0 - 200 ppm 1 ppm ± 2% of rdg. ± 10 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm F - Formaldehyde (CH2O) 3,4 EC 2 H - Hydrogen Sulfide (H2S) 1 EC2 0 - 10,000 ppb 0 - 100 ppm 1 ppb ± 5% od rdg. ± 50 ppb 1 ppm ± 4% of rdg. ± 0.5 ppm N - Nitrogen Dioxide (NO2) 1 EC 2 0 - 20 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm O - Oxygen (O2) S - Sulfur Dioxide (SO ) 1 X - Nitric Oxide (NO) 1 2 EC 2 EC2 EC 2 0 - 25% 0 - 20 ppm 0 - 250 ppm 0.1% ± 0.1% vol rdg. 0.1 ppm ± 4% of rdg. ± 0.5 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm 1. Other Ranges are Available Upon Request 2. Electrochemical 3. Accuracy Based on Laboratory Conditions 4. This sensor may have interference from H , CO, H S and other reducing gases such as alcohols Optional Accessories VOC NO2 O2 SO2 CO % RH H2S AQ Gas® Real-Time Datalogging Software Distributed By: Bulletin: AQPRO.2 Ed. 01/2017 Information & design subject to change at the man’ufacture’s discretion. Wireless Bluetooth™ Printer (EE900P) Sampling Probe (E85AACSF13) Moisture Exchange Tube for Calibration (AQMET) Zero Filter for Calibration (AQ CAL-ZF) Pitot Tube for Air Velocity (BB610032) E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 10

AQ EXPERT Portable Indoor Air Quality Monitor Providing the latest in Monitoring & Data Logging for IAQ testing in Buildings, Hospitals, Universities, Labs, Clean Rooms, Airports & more Customize UP to 7 Gases (Multiple Parameters - Up to 12) REAL-TIME Continuous Data-Logging Long Lasting Rechargeable Battery Large Internal Memory (2000) PC Software & USB Included Easy to Use Menu System Optional Wireless Printer Portable w/ Swivel Handle Barometric Air Pressure Dual Temp TcK Inputs Optional Air Sampling Probe Active Internal Sampling Pump MADE IN USA “Built with Quality in Mind” Real-Time Data-Logging Software For Graphs, Data Review, IAQ Reports Wireless Communications with Computer & Remote Printer Light Weight, Durable, and Easy to Transport Design % RH Temp Barometric Pressure CO2 CO VOC Formaldehyde NO2 NO O3 O2 H2S SO2 E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 11

AQ EXPERT Applications CO2, CO, % RH, Temp, TVOC’s, O2, NO, NO2, O3, CH2O, SO2, H2S, Barometric Pressure Features Custom to Your Application Up to 7 different toxic gases to meet the needs of most air quality analyses REAL-TIME Data Logging Save and graph using USB or wireless Bluetooth to a Computer or Tablet NO2 NO VOCs CH2O SO2 VOCs CO2 Easy Calibration Built-in menu driven calibration procedure Made in USA Designed and manufactured in the USA AQ Gas® Real-Time Datalogging Software O2 H2S CO % RH E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 12

AQ EXPERT Specifications Parameter Sensor Range Res. CO2 NDIR 0 - 5,000 ppm 1 ppm CO2 NDIR 0 - 20% 0.1% CO1 Electrochemical 0 - 200 ppm 0.1 ppm % RH Thin Film Capacitive 5 - 95% RH 0.1% RH Ambient Temperature VOCs Pt100 PID -40 - 257°F (-40 - 125°C) 0.1°C/F 0 - 20,000 ppb 1 ppb (0 - 46,000 µg/m3) (1 µg/m3) VOCs O2 PID Electrochemical 0 - 200 ppm (0 - 460 mg/m3) 0 - 25% 1 ppm (1 mg/m3) 0.1% Ozone (O3) H2S1 Electrochemical Electrochemical 0 - 5 ppm 0 - 100 ppm 1 ppb 1 ppm Accuracy ±2% of rdg. ±10 ppm ±3% of rdg. ±4% of rdg. ±0.5 ppm ±2% RH ±2°F (32-140°F) (± 0.4°C [0-60°C]) ±10 % of rdg. ± 20 ppb ±10 % of rdg. ± 2 ppm ±0.1% vol rdg. ±4% of rdg. ± 0.5 ppm CH O 2,3 2 NO1 NO2 1 SO 2 1 Barometric Pressure Electrochemical Electrochemical Electrochemical Electrochemical Solid State 0 - 10,000 ppb 0 - 250 ppm 0 - 20 ppm 0 - 20 ppm 260 - 1260 mbar 1 ppb 0.1 ppm 0.1 ppm 0.1 ppm 1 mbar ±5% of rdg. ± 50 ppb ±4% of rdg. ±0.5 ppm ±4% of rdg. ±0.5 ppm ±4% of rdg. ±0.5 ppm ±2 mbar Differential Pressure Temperature Type K T1 & T2 Air Velocity Bridge Tc K Calculated ± 40.0 inH2O (± 100 mbar) 0 - 2000°F (0 - 1100°C) 0 - 300 ft/sec 0.1 inH2O (0.25 mbar) 1°C/F 1 ft/sec ±1% of rdg. ± 2% of rdg. Electromagnetic compatibility EN 61326-1, Portable Equipment 1. Other Ranges are Available Upon Request 2. Accuracy Based on Laboratory Conditions 3. This sensor may have interference from H , CO, H S and other reducing gases such as alcohols Accessories Wireless Bluetooth Printer Air Velocity w/ Pitot Tube Sampling Probe Carrying Case Moisture Exchange Tube for Calibration Ambient Air Zero Filter E Instruments International www.E -In s t.c o m P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

[close]

p. 13

AQ EXPERT AQ EXPERT ORDERING CODE Part Number: EXPERT-___-___-___-___-___ (Example: EXPERT-C2-C-V1 = Ambient Temp, % RH, Barometric Pressure, CO2 (0-5000 ppm), CO (0-200 ppm), VOC (0-20,000 ppb) AQ EXPERT Base Unit Including: - Ambient Temperature, % Relative Humidity - Barometric Pressure, Wet Bulb & Dew Point - Continuous Internal Sampling Pump - REAL-TIME data logging - PC Software (with USB Cable) - Wireless Bluetooth & External Dongle - Dual-channel TcK (Diff. Temp) - Differential Pressure - Differential Temperature - Operating Manual - Swivel Handle for Easy Transport - Rechargeable Battery & AC Charger - Factory Calibration Certificate ADD UP TO 7 (SEVEN) ADDITIONAL SENSORS FROM THE LIST BELOW: PART NUMBER DESCRIPTION Expert- *-C2 *-C AQ Expert Base Unit w/ Ambient Temp, %RH, Barometric Pressure CO2 Sensor (0-5,000 ppm) CO Sensor (0-200 ppm ) -V1 VOC Sensor (0-20,000 ppb) -V2 *-N -Z *-H -O *-S *-X VOC Sensor (0-200 ppm) NO2 Sensor (0-20 ppm)** O3 Sensor (0-5 ppm)** H2S Sensor (0-100 ppm) O2 Sensor (0-25%) SO2 Sensor (0-20 ppm)** NO Sensor (0-250 ppm) -F CH2O Sensor (0-10,000 ppb) * Other Ranges are Available Upon Request ** Note: All 3 O3, NO2, & SO2 Sensors Cannot Concurrently be Installed on one Instrument OPTIONAL ACCESSORIES: PART NUMBER DESCRIPTION E858140 AQ CAL-ZF AQ MET E85AACSF13 EE900P BB610032 AACKP01 Protective Carrying Case Ambient Air Zero Filter Moisture Exchange Tube for Calibration 12” (300mm) Probe, 10’ (3m) Dual Hose Bluetooth Wireless Printer 12” (300mm) Pitot Tube (Air Velocity) Differential Pressure Kit E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 Bulletin: AQEXPERT.2 Ed. 01/2017 Information & design subject to change at the manufacture’s discretion.

[close]

p. 14

Built With Quality In Mind E Instruments International is a designer, manufacturer, & provider of a complete range of innovative instrumentation solutions including Indoor Air Quality Monitors, portable combustion gas analyzers, and gas leak detectors, which we export to over 65 countries worldwide. For more information about our products please call: (215) 750-1212 or visit our website at: www. E-Inst.com