Infrared Radiators

[close]

p. 2

Infra Red Elements Ceramic elements: Full trough element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3 Half trough element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4 Large full trough element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5 Quarter curved element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6 Quarter trough element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7 Flat elements: Full flat element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8 Half flat element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9 Large full flat element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10 Quarter full element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11 Suare flat element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12 Hollow elements: Full flat hollow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13 Half flat element hollow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14 Quarter flat element hollow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15 Square flat element hollow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16 Ceramic bulbs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quartz elements: Full quartz element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Half quartz element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quarter quartz element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Square quartz element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single tube quartz heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pillared full quartz element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pillared half quartz element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quartz halogen / tungsten element: Fast medium wave emitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . Short wave emitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FastIR systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17 page 18 page 19 page 20 page 21 page 22 page 23 page 24 page 25 page 26 page 27 page 28 Projectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 29 Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 30 Panel heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 31 Comfortir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 33 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 35 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 2 CVR No.: 42 16 59 13

[close]

p. 3

Member of the NIBE Group FTE - Full trough element Standard Features • • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions UL approved Recommended radiation distance from heater is 100 mm to 200 mm Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J FTE Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 150 262 750 9 (5.8) 250 354 750 15 (9.7) 300 400 750 18 (11.6) 400 464 750 24 15.5) 500 486 750 30 (19.4) 650 589 750 39 (25.2) 750 634 750 45 (29) 1000 722 750 60 (38.7) 180 g 245 x 60 x 31mm Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 3

[close]

p. 4

HTE - Half trough element Standard Features • • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions UL approved Recommended radiation distance from heater is 100 mm to 200 mm. Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J HTE Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 125 354 750 15 (9.6) 150 400 750 18 (11.6) 200 464 750 24 (15.5) 116 g 122 x 60 x 31mm 2 to 10μm 250 486 750 30 (19) 325 634 750 39 (25) 500 722 750 60 (38) Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 4 CVR No.: 42 16 59 13

[close]

p. 5

Member of the NIBE Group LFTE - Large full trough element Standard Features • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions Recommended radiation distance from heater is 100 mm to 200 mm Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J LFTE Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 1000 511 750 36 (23) 369 g 245 x 110 x 37mm 2 to 10μm 1500 596 750 54 (34) Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 5

[close]

p. 6

QCE - Quarter curved element Standard Features • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions Recommended radiation distance from heater is 100 mm to 200 mm Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J QCE Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 150 440 750 34 (22) 75 g 60 x 55 x 40mm 2 to 10μm 250 592 750 56 (36) Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 6 CVR No.: 42 16 59 13

[close]

p. 7

Member of the NIBE Group QTE - Quarter trough element Standard Features • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions Recommended radiation distance from heater is 100 mm to 200 mm Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J QTE Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 125 486 750 30 78 g 60 x 60 x 31mm 2 to 10μm 250 722 750 60 Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 7

[close]

p. 8

FFE - Full flat element Standard Features • • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions UL approved Recommended radiation distance from heater is 100 mm to 200 mm Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J FFE Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 150 262 750 9 (5.8) 250 354 750 15 (9.7) 300 400 750 18 (11.6) 400 464 750 24 (15.5) 500 486 750 30 (19.4) 650 589 750 39 (25.2) 750 634 750 45 (29) 1000 722 750 60 (38.7) 206 g 245 x 60 x 24mm 2 to 10 μm Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 8 CVR No.: 42 16 59 13

[close]

p. 9

Member of the NIBE Group HFE - Half flat element Standard Features • • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions UL approved Recommended radiation distance from heater is 100 mm to 200 mm. Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J HFE Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 125 354 750 15 (9.6) 150 400 750 18 (11.6) 200 464 750 24 (15.4) 250 486 750 30 (19.3) 325 634 750 39 (25) 500 722 750 61 (39.3) 113 g 122 x 60 x 24mm 2 to 10 μm Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 9

[close]

p. 10

LFFE - Large full flat element Standard Features • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions Recommended radiation distance from heater is 100 mm to 200 mm Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J LFFE Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 150 204 750 5.4 (3.4) 350 338 750 12 (7.6) 342 g 245 x 95 x 24mm 2 to 10 μm 750 501 750 27 (17) 1400 667 750 50 (31.9) Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 10 CVR No.: 42 16 59 13

[close]

p. 11

Member of the NIBE Group QFE - Quarter flat element Standard Features • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions Recommended radiation distance from heater is 100 mm to 200 mm Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J QFE Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 125 486 750 30 107 g 60 x 60 x 24mm 2 to 10 μm 250 722 750 60 Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 11

[close]

p. 12

SFSE - Square flat solid element Standard Features • • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions UL approved Recommended radiation distance from heater is 100 mm to 200 mm Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J SFSE Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 150 262 750 9 (5.8) 250 354 750 15 (9.7) 300 400 750 18 (11.6) 350 420 750 21 (13.5) 400 464 750 24 (15.5) 500 486 750 30 (19.4) 650 589 750 39 (25.2) 750 634 750 45 (29) 231 g 122 x 122 x 24mm 2 to 10 μm Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 12 CVR No.: 42 16 59 13

[close]

p. 13

Member of the NIBE Group FFEH - Full flat hollow element Standard Features • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions Recommended radiation distance from heater is 100 mm to 200 mm Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J FFEH Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 250 383 750 15 (9.7) 300 400 750 18 (11.6) 400 488 750 24 (15.5) 500 535 750 30 (19.4) 600 563 750 36 (23.2) 800 670 750 48 (31) 222 g 245 x 60 x 36mm 2 to 10 μm Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 13

[close]

p. 14

HFEH - Half flat hollow element Standard Features • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions Recommended radiation distance from heater is 100 mm to 200 mm. Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J HFEH Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 125 383 750 15 (9.7) 200 488 750 24 (15.5) 250 535 750 30 (19.3) 106 g 122 x 60 x 36mm 2 to 10 μm 300 563 750 36 (23.2) 400 670 750 48 (31) Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 14 CVR No.: 42 16 59 13

[close]

p. 15

Member of the NIBE Group QFEH - Quarter flat hollow element Standard Features • • • • • • Iron-chrome aluminium resistance wire Heater Voltage: 230 Volts standard (other voltages available on request) Useful wavelength range: 2-10 microns Average Operating Life-Up to 20,000 hrs depending on conditions Recommended radiation distance from heater is 100 mm to 200 mm Supplied with 100mm ceramic beaded power leads Options available: Colours: Wire terminations: Thermocouples White, yellow, coral, black Others on request Ferrule (standard) Ring termination Type K, Type J QFEH Wattage Mean surface temp (0C) Max permissible operating temp (0C) Max power density kW/m2 (Winch2) Average weight Dimensions Useful wavelength range 125 535 750 30 75 g 60 x 60 x 36mm 2 to 10 μm 200 670 750 48 Heat up / cool down graphs Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 15