SAN Industrial Radiators

 

Embed or link this publication

Description

SAN Industrial Radiators Catalogue

Popular Pages


p. 1

Industrial Radiators

[close]

p. 2

Radiators etc. Tubular Radiators: Finned tubular element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Finned tubular radiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Finned tubular radiator, EX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard tubular radiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3 page 4 page 5 page 6 Church radiators: Panel radiators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7 Convector radiators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8 Radiation heaters: Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9 Infra red armature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10 Radiation heating panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11-12 Panel radiators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13 Heating mats and jackets: Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Antenna heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Container heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Silicone heating mats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quartz heating mats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glass cloth heating mats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Metal heating mats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drum heaters: Band heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drum heater and base heater . . . . . . . . . . . . . . . . . . . . . . . . . . EX-drum heater and base heater . . . . . . . . . . . . . . . . . . . . . . . Gas bottle heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14 page 15 page 16 page 17 page 17 page 17 page 17 page 18 page 19 page 20 page 21 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 2 CVR No.: 42 16 59 13

[close]

p. 3

Member of the NIBE Group Finned Tubular Elements The SAN finned tubular elements type AL are especially developped to avoid condensation in automatic cabinets - terminal boxes, cold falling down from large window areas etc. Material : ture Finned tube Connection Surface temp. Dimensions : stainless steel SIS 2350, ∅ 42 mm : plastic with PG 11 gland, IP 54 : 150ºC at 22ºC ambient tempera: A: total length B: heating zone FINNED TUBULAR ELEMENT, AL Type AL 0,5 AL 1 AL 1,5 AL 2 AL 4 AL 6 Power W 60 115 165 200 400 600 Voltage V 230 230 230 230 230 230 L mm 230 350 470 575 1000 1500 C mm 120 245 375 495 905 1405 230V Part no. 83117 83103 83104 83105 83126 83127 Suggestions for thermostat: type KTO miniature. L 38,5 Ø16 19 10 2 15 C 61 85 18 6,5 8,5 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 30 3

[close]

p. 4

Finned Tubular Radiator Type A The SAN finned tubular radiator type A is an industrial radiator for heating of rooms - garages - cabinets etc., with great demands for a robust construction. Delivered in grey painted steel. Finned tubular radiator type A is delivered as standard, see below scheme. Upon request the A can also be delivered with other voltage, power and length. SPECIAL VERSION: vibration- and shock safe, e.g. for use on ships. Surface temperature: 120ºC at 22ºC ambient temperature. FINNED TUBULAR RADIATOR, A Type A5 A10 A15 A20 A5 A10 A15 A20 A30* A40* Power W 500 1000 1500 2000 500 1000 1500 2000 3000 4000 Voltage V 230 230 230 230 400 400 400 400 400 3x400 A mm 530 930 1330 1730 530 930 1330 1730 1730 1730 B mm 350 750 1150 1550 350 750 1150 1550 1550 1550 230V Part no. 832001 832011 832021 832031 832051 832061 832071 832081 83225 83226 *Higher surface temperature. A 110,00 B 157,00 GRATING Protection grate for A5, L = 650mm Protection grate for A10, L = 1050mm Protection grate for A15, L = 1450mm Protection grate for A20, L = 1850mm Height: 200mm. Width: 135 83245 83246 83247 83248 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 4 CVR No.: 42 16 59 13

[close]

p. 5

Member of the NIBE Group Finned Tubular Radiator The SAN finned tubular radiator type SAN EEx is used for heating of room air, by convection in areas of zone 1-2. Environment temperature: -20ºC to +40ºC Installation: Horizontal Ignition protection mode: EEx de IIC "flameproof" "increased safety" Protection mode: IP 54 (IP 67 possible) Temperature class: T1 - T5 (T6 upon request) EG-Type Approval Certificate: PTB 02 ATEX 1040 Available surface finishes: L = Black enamel finish V = Galvanized/black enamel finish E = Stainless steel / aluminium lacquered. Nominal power / W: From 50 to 2200W, please ask for detailed specification sheet. Length: From 650 to 2270 mm, please ask for detailed specification sheet. Applications: • Screening plants of sewage treatment plants • Gas regulator stations • Filling stations for gaseous fuels • Colour storage rooms • Chemical tankers • Offshore drilling platforms OPTIONAL: Where there are no special requirements on the accuracy of temperature, SAN EEx radiator can be delivered with built-in thermostat, 0-40ºC. For precise controlling please use separate temperature controller. SAN EEx radiator can also be delivered with a protection grate. We offer the following types: Type "M": Type "S": Protection grate with skewed front, objects hardly hold on the radiator, the risk of heat build-up is reduced. Protection grate, bent at a right angle, thermal contact protection. Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 5

[close]

p. 6

Tubular Radiator Type RO Tubular radiators are primarily used for heating of church rooms, halls, stables, locker rooms, toilets, containers or trailers etc. The radiator is designed from powder painted steel tube with stainless steel tubular heating elements and equipped with brackets for wall- or floor mounting. Due to the smooth surface of the radiator, is is very easy to clean. Mounting The tubular radiator must not be exposed to water or other fluids nor being covered. Also the radiator must not be placed close to inflammable materials. The tubular radiator can be mounted horizontally or vertically with the terminal box downwards. L-measure L=500mm L=750mm L=1000mm L=1250mm L=1500mm L=1750mm L=2000mm L=2250mm L=500mm L=750mm L=1000mm L=1250mm L=1500mm L=1750mm L=2000mm L=2250mm a-measure a=70mm a=80mm a=100mm a=125mm a=150mm a=175mm a=200mm a=225mm a=70mm a=80mm a=100mm a=125mm a=150mm a=175mm a=200mm a=225mm Voltage 230V 230V 230V 230V 230V 230V 230V 230V 400V 400V 400V 400V 400V 400V 400V 400V Type: RXXXA Thermo fuse: 150°C auto reset 250°C manual reset Approval: D, CE (EN-60335-1/ EN-60335-2-30) Protection class: IP55 Insulation class: Double insulated Surface temperature: Delta-T, max. 85°C Colour: RAL7004 (lysegrå) Power increments: 0.5 and 1 power unit Power 150W 225W 300W 375W 450W 525W 600W 675W 150W 225W 300W 375W 450W 525W 600W 675W Special versions, however max. 300W per meter tube please contact our sales department for further information and ordering. Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 6 CVR No.: 42 16 59 13

[close]

p. 7

Member of the NIBE Group Panel Radiators Type PO The SAN panel radiator PO is designed for mounting on wall or rack and is especially applicable for heating of church interior. The inside has been made from galvanized iron plate mounted with stainless tubular heating elements type BV and the outside from powder painted iron plate. It has a very low surface temperature and has a very low-volume operation. Voltage : 230 V, 400 V or 3 x 400 V Colour : white RAL 9016 78 300 Protection class : IP 22 PANEL RADIATOR type PO Type PO 10 PO 15 Power W 1000 1500 Length mm 800 1300 Part no. 82700 82705 300 175 L 242 L 87 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 7

[close]

p. 8

Convector Radiator Type KO The SAN convector radiators KO are especially designed for heating of church interior and are mounted below the benches or in convector pits. The construction fulfils the government circular from the Church Ministry of Aug. 10th 1993 concerning implementing and use of church heating systems. The convector radiator type KO is manufactured from powder painted steel plate, stainless tubular heating element and with fittings or legs for mounting under bench or on floor in convector pit respectively. Silent operation. Can be delivered with tubular heating element for 3 power steps (1/4 - 1/2 - 1/1). Power : Voltage : Max. length : Colour : Protection class : Surface temperature : approx. 400 W/m 230 V, 400 V or 3x400 V 2400 mm grey RAL 7032 IP 22 65ºC CONVECTOR RADIATOR type KO Type KO 65 KO 80 KO 90 KO 95 KO 100 KO 110 KO 125 KO 140 KO 150 KO 170 KO 190 KO 210 KO 230 Power W 260 325 405 380 450 450 500 560 600 680 760 840 920 Length mm 650 800 900 950 1000 1100 1250 1400 1500 1700 1900 2100 2300 230V Part no. 82600 82605 82606 82610 82611 82615 82620 82625 82630 82635 82640 82650 82655 78 300 300 175 L 242 L 87 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 8 CVR No.: 42 16 59 13

[close]

p. 9

Member of the NIBE Group Radiation Heater Type IR Infrared radiation heating (IR) is often the optimum heating solution. Infrared radiation is a part of the electromagnetic specter, which also includes e.g. visual light and radio waves. The IR rays do not - as e.g. convection heating - use a media for conveying the heat from the heating element to the product to be heated. Therefore the following 3 points describe radiation heating: Effective : Obtains very high degrees of heat transmission. Exactly applied and possibility of control by minimum peripheral heat loss. Fast : The energy is conducted at the velocity of light from the heating source to the product. Clean : No combustion products. No forced air streams lead contamination to the product. The SAN IR programme contains several various products, which have all been developped for different tasks. E.g. drying of car paint, heating of large halls. Construction The SAN ceramic radiation heating elements type IR are manufactured by casting a resistance spiral into a glazed screen made from a fireproof material and have thus been protected against moisture, oxidation and contamination. The glazing, the screen and the resistance spiral have been thoroughly chosen and composed, so that the required spectral, electrical, mechanical and thermal characteristics are obtained. When an electrical voltage runs through the resistance spiral, heat is generated. It is distributed evenly to the screen and submitted from the surface as infrared radiation. The glazing and the screen have been chosen to obtain a high radiation value. Main connections Mounting terminal Fastening spring and clip Spring fitting Reflector Heating element Element from fire proof material Glazing Casted resistance heating spirals Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 9

[close]

p. 10

Radiation Heater Type SAN Infra-Red The SAN INFRA-RED ceramic radiation heating element is for mounting in stainless radiation panels. Max. temperature: 755ºC. Can also be delivered with built-in thermo couple. SAN INFRA-RED Type Power W 125 150 IR 122 200 250 325 375 500 150 250 300 IR 245 400 500 650 750 1000 Power kW/m² 10 12 16 20 26 32 40 6 10 12 16 20 26 32 40 TYPE IR Surface temp. ºC 418 452 515 560 615 660 755 320 418 452 515 560 615 660 755 230V Part no. 96020 96021 96022 96023 96025 96025 96026 96001 96002 96003 96004 96005 96006 96007 96008 Reflector f/1 pc. IR 245 L = 295mm Reflector f/2 pcs IR 245 L = 545mm Reflector f/3 pcs IR 245 L = 795mm Reflector f/4 pcs IR 245 L = 1045mm 96100 96101 96102 96103 The SAN type Electro-sol is an IR-armature in mirror finished alu-profile and with built-in stainless heating element. Changing over possible ELECTRO-SOL Type SAN I SAN II SAN III Power W 160/325/650 250/500/1000 325/650/1300 I* mm 630 980 1280 Length mm 890 1240 1540 230V Part no. 83517 83518 83519 If your heating requirement demands other power or lengths than the mentioned standard types, these are available upon request. RADIATION PANELS are manufacture according to specification. * Heating zone Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 10 CVR No.: 42 16 59 13

[close]

p. 11

Member of the NIBE Group Radiation Heating Panel Type TTP and TTS Type TTP For room heating of e.g stocks, sports halls, workshops, radiation heating panels TTP and TTS can be used, as the radia-tion passes freely through the air and is not converted into heat until it reaches the floor or people. The surroundings thus reach a higher temperature than the ambient air, which then is heated by "contact". You feel that the temperature is higher than it actually is. The temperature of the air can therefore be kept lower than by hot-air plants. Type TTP is for rooms with floor-to-ceiling height from approx. 2.4 m to max. 10 m. The largest unit is 1200 W. Type TTS is for rooms with floor-to-ceiling height from approx. 2.5 m - 15-20 m. The biggest unit is 2100 W. Type TTP 400 TTP 600 TTP 900 TTP 1200 TTP 600 TTP 900 TTP 1200 TTS 1200 TTS 1700 TTS 2100 TTS 1200 TTS 1700 TTS 2100 Type TTS Power W 400 600 900 1200 600 900 1200 1200 1700 2100 1200 1700 2100 Voltage 230 230 230 230 400 400 400 230 230 230 400 400 400 Dim. mm LxWxH 600x170x70 900x170x70 1050x170x70 1350x170x70 900x170x70 1050x170x70 1350x170x70 800x280x70 1050x280x70 1350x280x70 800x280x70 1050x280x70 1350x280x70 Part no. 83376 83377 83378 83379 83380 83381 83382 83351 83352 83353 Technical data. Protection class: IP 44. Manufactured from painted steel plate (RAL 9010, white) and heating strips of anodized Alu-plate. Adjustment For controlling the temperature we recommend Triac control type TTC. With this you obtain a fast connection/disconnection at even heat distribution. Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 11

[close]

p. 12

Radiation Heating Panel Type TVH Type TVH The radiant panel heater type TVH is a roof oven suitable for heating of rooms with roof heights between approx. 4 and 20 metres. Typical application areas are airports, stores, sports halls, industrial- and storerooms, workshops, green houses etc. Also used for additional heating of cold work places and for drying of floors in entrance areas. The ovens can also be mounted tilted on the wall with a wall bracket (to be ordered separately). The biggest unit is 6000 W. Type TVH-2000-2 TVH-3000-2 TVH-4500-2 TVH-6000-2 TVH-3000-4 TVH-4500-4 TVH-6000-4 Power kW 2 3 4,5 6 3 4,5 6 Voltage 230/1 230/3 230/3 230/3 400/3 400/3 400/3 Dim. mm LxWxH 160x1280x70 220x1280x70 440x980x70 440x1280x70 220x1280x70 440x980x70 440x1280x70 Technical data. Protection class: IP 54. Manufactured with raw sintek back and side walls. The radiant surface is black painted steel. The surface temperature is approx. 400ºC, which gives a very high power. Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 12 CVR No.: 42 16 59 13

[close]

p. 13

Member of the NIBE Group Panel Radiators Type AP The SAN alu-panel radiators type AP are applicable for heating of cold falling down from large window areas. The small construction dimensions provide possibility of mounting almost everywhere. The alu-panels are delivered in 3 heights and either white- or bronze painted. Technical data Voltage : 230 V Protection class : IP 44 Dim. : Relief from wall : 35 mm Height: AP 400 : 150 mm AP 175 : 75 mm AP 125 : 45 mm Thermostat : Type AP 400 can be delivered with thermostat: Fx 400t : bimetal Fx 400e : electronic Fx 400cm : electronic with reduction of night temp. Type AP 175 Power W 175 260 350 435 525 610 700 Length mm 1150 1650 2150 2650 3150 3650 4150 175W/m Part no. 83616 83618 83620 83622 83624 83626 83628 Type AP 125 Power W 125 185 250 310 375 435 500 Length mm 1150 1650 2150 2650 3150 3650 4150 125W/m Part no. 83630 83632 83634 83636 83638 83640 83642 Type AP 400 Power W 250 350 525 700 875 1050 1225 1400 AP 400T AP 400E AP 400EM Length mm 900 1150 1650 2150 2650 3150 3650 4150 - ºC 350W/m Part no. 83600 83602 83604 83606 83608 83610 83612 83614 83644 83646 83642 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 13

[close]

p. 14

Flexible Heating Mats and Jackets Vaccuum chamber. Vacuum pump. Vessel for polyol and isocyanat for the production of PUR foam. Flexible heating mats and jackets are the optimum way of heating with high effect and good heat distribution. The • • • • • • • • • • benefits are: easy to remove and to exchange easy to install applicable in sophisticated applications high life time tailormade to the shape of vessels, pipes, valves or pumps operating temperatures from 0º up to 900ºC efficient heating system optimum heat distribution for hazardous areas too including insulation Collimator for high density radiation. Experimental system for catalysator development. Design of heating mats and jackets Nominal temperature Nominal voltage Maximum heat density Material of heating surfaces Fasteners Primary insulation of heating wires Thermal insulation Outer surface of thermal insulation Plastic fabric with and without PU/PVC coating Glass cloth tape PTFE Plastic foam 80º - 900ºC <= 500V 500W/m² - 20.000W/m² Possible combinations Fibreglass with silicone or PTFE coating Eyelets, hooks, velcro fasteners Fibre glass Glass felt Fibreglass without coating Glass cloth tape with silicone adhesive Quartz fabric Silicone foam Quartz fabric without coating Quartz lacing Fibreglass lacing Quartz fabric Quartz felt Ceramic wool The low surface temperatures on the outside of the insulation allow the use of following materials: Plastic fabric with or without coating up to 80ºC, Aluminium coated fibreglass up to 160ºC, Fibreglass coated with silicone or PTFE up to 220ºC, Fibre glass or quartz without coating will be used for higher surface temperature. Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 14 CVR No.: 42 16 59 13

[close]

p. 15

Member of the NIBE Group Antenna Heating Satellite receiver with heating. Icing and snow fall on antennas desturb the optimum receipt and operation. This especially happens on parabolic reflector systems. In commercial operation of antenna systems these drop outs can cause high expenses. SAN heating effectively prevents snow and icing and keeps the antenna operation noiceless. During the last couple of years our customers have used more than 1000 SAN heating systems. The antenna heating systems in larger quantities as complete cup systems. At minor quantities or for single cases we pro-ject, deliver and mount individually. Technical data: Heating types: • constructively fitted heating cups in styrosun for antennas of between approx. 0,8 to approx. 5 m diameter. The cups are usually fastened by special clamping units. • PTFE-cable • parallel heating elements • heating sticks • heating mats • air heaters All heating methods can according to technical demands be projected for full diameter or only for the lower half. Regulation: Capillary pipe regulator/electronic regulator, air thermostat or electronic control type ELSAT-1 or ELSAT-2 comprising all important temperature data and monitoring- and heating systems. Power: Approx. 500-600 W/m2 / 230 or 400 Volt. Temperatures: -30 to +70ºC. Mounting: By SAN-employees in our own factory or by the customer according to detailed supervision. At bigger plants with more than 5 m Ø we offer individual solutions for each assignment, incl. SAN-mounting or mounting monitoring on site. Reference list: 1. 2. 3. 4. Kathrein Precision Vertex Prolin 5. Andrew 9. Technisat 6. Bosch 10. Hatsushita/Panasonic 7. Hirschmann 11. Hômann 8. Alcatel Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 15

[close]

Comments

no comments yet