SAN Heating Cables

 

Embed or link this publication

Description

SAN Heating Cables Catalogue

Popular Pages


p. 1

Heating Cables

[close]

p. 2

Heating Cables Index Page Selfregulating Heating Cables Standard types 65-100˚C................................................................................................................................ High temperature 210-250˚C........................................................................................................................... DomoClick, connection technique.................................................................................................................. Technical information. ...................................................................................................................................... Parallel Heating Cables Standard types ............................................................................................................................................... Industrial Heating Cables 4-Conductor ................................................................................................................................................... Silicone............................................................................................................................................................ Teflon PTFE. ..................................................................................................................................................... Fibreglass ....................................................................................................................................................... Mineral insulated ........................................................................................................................................... Textile quartz .................................................................................................................................................. Heating Mats.................................................................................................................................................. Heat Loss Tables........................................................................................................................................... 4 14 20 22 24 30 31 32 42 46 50 52 53 Compressor Pre-heater................................................................................................................................. 55 Drain line heating cable................................................................................................................................ 56 Ice and Snow Detector.................................................................................................................................. 57 Thermostats................................................................................................................................................... 59 Temperature Limiters.................................................................................................................................... Control and Monitoring................................................................................................................................. Applications................................................................................................................................................... Mounting Instructions................................................................................................................................... Accessories................................................................................................................................................... SAN Quick Guide for Heating Cables.......................................................................................................... Floor Heating Cables SAN Thermo-net. ............................................................................................................................................. SAN El-Mix...................................................................................................................................................... Floor Heating Thermostats.............................................................................................................................. Accessories..................................................................................................................................................... 62 64 66 67 68 75 76 77 80 82 DEMKO: Approval for the Danish market FIMKO: Approval for the Finnish market VDE Approval Suitable for contact with foodstuff/Suitable for use in drinking water SEMKO: Approval for the Swedish market Approval for the French market EX Approval terminated NEMKO: Approval for the Norwegian market Gost: Approval for the Russian market Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 2 CVR No.: 42 16 59 13

[close]

p. 3

Member of the NIBE Group Selfregulating Heating Cable 1. Tinned copper wire. 2. Selfregulating synthetic heating element. 3. Outer XPE-insulation The ELSR heating cable can be used for frost protection and maintaining constant temperatures for receptacles, pipes, valves and gutters etc. Except for the connections, the heating cable may be immersed in fluids. If used in an aggressive environment (the Chemicals or Petrochemicals industry), we lag the heating cable with a special chemically resistant outer jacket (flouropolymer), option “BOT”. Function: Selfregulating heating cables consist of two parallel bus wires embedded in a networked plastic heating element, doped with surroounding carbon particles. If the temperature increases during operation, the plastic expands due to molecular expansion and the distances between the carbon particles increases. Resistance increases and output drops. When it cools down, this process is reversed and output increases. This physical property not to exceed the specified temperatures also facilitates the cross-routing of self-regulating cables and managing without a temperature cut-out device. 4. Tinned copper braiding / alu-foil. 5. Outer synthetic jacket TPE-O. Advantages: • Self-regulating with adaptable output • Various temperature range applications • Demand-orientated output grading • High chemical resistance • No temperature limitation required • Can be cut to length from the roll EEx-approval SAN selfregulating heating cable can be installed in hazardous areas, when the cable a.o. is equipped with special termination kit. Contact our sales department for further information. Approvals: EEx e II T6 EEx ed II C T6 Ex-certificate according to EN Eexe II T6, LCIE 96.D6141X. Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 3

[close]

p. 4

Selfregulating heating cable Type ELSR-M up to 65°C Ou te c r ja ke t n tio tec ium o r n P mi Alu r pe op th c r a ed lat ive e -p Tri tect pro es r wi Ins ula n tio ing t lat en ire gu elem e r sw 2 lf Bu 6mm Se ating 0.5 he • • • • • Self-regulating Two nominal outputs Can be cut to length from the roll Moisture proof UV-resistant The ELSR-M heating cable offers you the smallest possible dimensions, is highly flexible in its application and perfectly suited to use for short heating circuits. A further feature: the ELSR-M-BF heating cable can be laid fully immersed in water, even its end contacts are moisture proof! Technical Data: Outer jacket, thermoplastic.............................................. TPE-O Bus wire. ........................................................... Cu nickel-plated Maximum exposure temperature (deenergized)................ 65°C Maximum exposure temperature (energized).....................65°C Nominal voltage................................................................. 230V Min. bending radius......................................................... 25mm Min. installation temperature. ............................................ -45°C Applications: ELSR-M is a self-regulating heating cable with a lightweight (“micro”) design, suitable for use in industry and house construction. The applications range from frost protection to temperature maintenance for pipes and receptacles. (Temperatures up to 65ºC). For example, the cable is used when heating tube bundle cables for water analysis. The food approved outer jacket is a special highlight of the ELSR-M and you can order it as variant ELSR-M-BF. Alternatively, you can be provided with the M tape, also with aluminium foil and a thermoplastic outer jacket (ELSR-M-AO) or with braiding and a thermoplastic outer jacket. Type Nom. loading at 10°C (W/m) 10 15 15 10 14 Max. allowed ambient temperature power on power off 65 65 65 65 65 For box PG 16 For cold cable or splicing 65 65 65 65 80 Earth braiding Braiding Alu-foil Braiding Alu-foil Tinned copper braiding Dimensions (mm) 8.5x5.8 8.0x5.5 8.5x5.8 7.5x4.9 8.9x6.1 Part no. ELSR-M-10-2-BO** ELSR-M-15-2-AO* ELSR-M-15-2-BO** ELSR-M-10-2-BF* ELSR-S-BOT* Termination kit * On stock ** Not on stock 3660013 3660014 3660015 3660006 3660007 7399120 7399108 Design: BO: AO: BF: BJF: Protective braiding and a thermoplastic outer jacket. Aluminium foil and a thermoplastic oouter jacket. Protective braiding and food safe outer jacket, suitable for use with drinking water. Teflon-PFA Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 4 CVR No.: 42 16 59 13

[close]

p. 5

Member of the NIBE Group Selfregulating heating cable Type ELSR-M up to 65°C ire sw 2 Bu 6mm 0.5 ing t lat en gu elem e r lf Se ating he la su tio n op d c ive e t la tect -p Tri r pro g e p idin bra r ute jac ke t In O 35 ELSR-M-...-2 output (on insulated metallic pipes in accordance with EN 62395-1) Heating curcuit lengths ELSR-M-...-2 Heating output [W/m] 30 25 20 15 10 5 0 -30 –20 –10 0 10 20 30 40 50 60 considering • 230V nominal voltage • Delayed action circuit breakers (C-characteristic) with 80 per cent maximum load • Maximum 10 per cent line voltage drop on the heating cable bus wire • A (1) single end power input heating cable into consideration Switch-on temperature (°C) +10ºC 0°C Nominal cutout value (A) 16 20 16 20 16 20 -20°C -40°C 16 20 16 20 Heating circuit length (m) for ELSR-M-10-2 ELSR-M-15-2 126.5 126.5 115.5 115.5 106.5 106.5 99.5 99.5 88.5 88.5 105.5 105.5 97.5 97.5 91.0 91.0 85.5 85.5 77.0 77.0 EL SR -M ELS -15 R-M -2 -10ºC -10 -2 Pipe temperature [0C] Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 5

[close]

p. 6

Selfregulating parallel heating cable Type ELSR-N up to 80°C r ute k jac et l e tiv foi tec ium o r n i P m alu r pe op th c ar ed lat ive e -p Tri tect n tio pro es ula r s i n I w ing t lat en gu elem e r lf Se ating he ire sw 2 Bu 3mm 1.2 O The versatile self-regulating heating cable ELSR-N is suited for frost protection and temperature maintenance in the low temperature range of industrial applications. Likewise it is approved for use in hazardous areas. The BOT version of this heating cable even withstands aggressive chemicals, oil and fuel and, thanks to this high chemical resistance, stands out for a long lifetime. Applications: • Frost protection • Heat tracing on level indicators • Chemical & petrochemical industries • Tank bottom heating of LNG storage tanks • Pipe het tracing • Vesels and tanks • Automotive • Food processing industry Type Nom. output at 10°C (W/m) 10 10 10 20 20 20 30 30 30 40 40 40 • • • • • • Self-regulating Four nominal outputs Can be cut to length from the roll Moisture proof UV-resistant Approved for use in hazardous areas Technical Data: Outer jacket...................................................................... TPE-O Bus wire. .....................................................nickel-plated copper Maximum exposure temperature (deenergized).................80°C Maximum exposure temperature (energized).....................65°C Nominal voltage..................................................................230V Bending radius minimum..................................................25mm Minimum installation temperature. .................................... -45°C Classification..................... II 2G Ex e IIC Gb II 2D Ex tb IIIC Db Certificates.........................IICEx EPS 12.0006U 12ATEX1431U Dimensions approx. (mm) Weight approx. (g/m) Part no. ELSR-N-10-2-AO ELSR-N-10-2-BO ELSR-N-10-2-BOT ELSR-N-20-2-AO ELSR-N-20-2-BO ELSR-N-20-2-BOT ELSR-N-30-2-AO ELSR-N-30-2-BO ELSR-N-30-2-BOT ELSR-N-40-2-AO ELSR-N-40-2-BO ELSR-N-40-2-BOT Design: BO: AO: BOT: 13.6x5.5 14.1x5.8 13.8x5.6 13.6x5.5 14.1x5.8 13.8x5.6 13.6x5.5 14.1x5.8 13.8x5.6 13.6x5.5 14.1x5.8 13.8x5.6 91 108 108 91 108 108 91 108 108 91 108 108 3660050 3660109 3660110 3660053 3660209 3660120 3660056 3660309 3660130 3660059 3660409 3660140 Protective braiding and a thermoplastic outer jacket Aluminium foil and a thermoplastic outer jacket Protective braiding and a fluorpolymer outer jacket Termination Kit Description For box PG16 For box PG16 For box M25 For box M25 For cold cable Part no. 7399101 7399106 7399114 7399116 7399108 EX-termination Kit ELSR-N-10/20 ELSR-N-30/40 ELSR-N-10/20 ELSR-N-30/40 Description Complete w/M20 brass gland Complete w/M20 brass gland Complete w/M20 plastic gland Complete w/M25 plastic gland Part no. 7399030 7399032 7399034 7399036 ELSR-N-10/20 ELSR-N-30/40 ELSR-N-10/20 ELSR-N-30/40 ELSR-N-10/20/30/40 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 6 CVR No.: 42 16 59 13

[close]

p. 7

Member of the NIBE Group Selfregulating parallel heating cable Type ELSR-N up to 80°C wi us ² b per m 3m cop 1.2 ned n i t re ing t lat en gu elem e r f l Se ating he la su t ion ra ed lat ive b -p Tri tect pro idi ng O r ute jac ke t In (on insulated metallic pipes in accordance with EN 62395-1) 70 ELSR-N-...-1 output (110V) (on insulated metallic pipes in accordance with EN 62395-1) 70 60 50 40 30 20 10 0 –30 –20 –10 0 10 20 30 40 50 60 Heating output [W/m] ELSR-N-...-2 output (230V) 60 50 40 30 20 Heating output [W/m] ELS ELS EL EL SR SR R-N -30 1 -N -40 -2 10 0 –30 –20 -N ELSR R-N -1 ELS ELSR R-N -30 -N-10 -20- -1 -2 -20 -2 -N-1 0-2 –10 0 10 20 30 40 50 60 Pipe temperature [0C] Heating curcuit lengths ELSR-N-...-1 (110V) Pipe temperature [0C] Heating curcuit lengths ELSR-N-...-2 (230V) considering • 110V nominal voltage • Delayed action circuit breakers (C-characteristic) with 80 per cent maximum load • Maximum 10 per cent line voltage drop on the heating cable bus wire • A (1) single end power input heating cable into consideration Switch-on temp. °C Nominal cutout value A 10 +10ºC 16 20 25 10 0°C 16 20 25 10 -10˚C 16 20 25 10 -20°C 16 20 25 10 -40°C 16 20 25 Heating circuit length (m) for ELSR-N- 10-1 76 90 90 90 63 82,5 82,5 82,5 54 76 76 76 46 71 71 71 37 59 63 63 ELSR-N- 20-1 48 72 72 72 40 64 66 66 35 55 61 61 30 48 57 57 24 39 48 51 ELSR-N- 30-1 32 52 59 59 27 44 54,5 54,5 24 38 47 50,5 21 33 42 47,5 17 27 34 42 considering • 230V nominal voltage • Delayed action circuit breakers (C-characteristic) with 80 per cent maximum load • Maximum 10 per cent line voltage drop on the heating cable bus wire • A (1) single end power input heating cable into consideration Switch-on temp. °C Nominal cutout value A 16 +10ºC 20 25 16 0°C 20 25 16 -10˚C 20 25 -20°C 16 20 25 16 -40°C 20 25 Heating circuit length (m) for ELSR-N10-2 177.0 177.0 177.0 160.0 160.0 160.0 144.0 149.0 149.0 125.0 139.0 139.0 99.0 124.0 124.0 ELSR-N20-2 109.0 129.0 129.0 92.0 115.0 119.0 79.0 99.0 111.0 70.0 87.0 104.0 56.0 71.0 88.0 ELSR-N30-2 83.0 104.0 113.0 71.0 89.0 105.0 63.0 78.0 98.0 56.0 69.0 87.0 45.0 57.0 71.0 ELSR-N40-2 57.0 71.0 89.0 50.0 62.0 78.0 44.0 55.0 69.0 40.0 50.0 62.0 33.0 42.0 52.0 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 7

[close]

p. 8

Selfregulating parallel heating cable Type ELSR-R up to 55°C r ute k jac et l e tiv foi tec ium o r n i P m alu r pe op th c r a ed lat ive e -p Tri tect n tio pro es ula r s i n w I ing t lat en gu elem e r lf Se ating he ire sw 2 Bu 6mm 0.5 O • • • • • Round cable form Self-regulating Can be cut to length from the roll Moisture proof UV-resistant Moreover, the heating cable ELSR-R is damp-protected and UVresistant as are all our self-regulating heating cables. Technical Data: Outer jacket...................................................................... TPE-O Bus wire. ........................................................... Cu nickel-plated Maximum exposure temperature (deenergized).................55°C Maximum exposure temperature (energized).....................55°C Nominal voltage..................................................................230V Bending radius minimum..................................................30mm Minimum installation temperature. .................................... -30°C Applications: The “R” in the name of our self-regulating heating cable ELSR-R is an abbreviation for “round”. This heating cable was specially developed to protect the doors and seals of refrigerating chambers against frost as well as all for applications requiring a round heating cable. It is often used in cold water lines by breweries and drinks manufacturers (as frost protection). The maximum exposure temperature is 55°C. Type Nom. output at 10°C (W/m) 19W/m at 10°C 19W/m at 10°C 19W/m at 10°C 19W/m at 10°C Dimensions approx. (mm) Weight approx. (g/m) Part no. ELSR-R-19-2-B ELSR-R-19-2-BO ELSR-R-19-2-AO ELSR-R-19-2-OT* 7.4 8.2 8.0 7.5 63 74 82 63 3660080 3660081 3660082 3660083 * This heating cable is explicitly developed for the operation in cold room doors. Please approach our sales engineers for advice on our ELSR-R-19-2-OT. Design: B: BO: AO: OT: Protective braiding Protective braiding and a thermoplastic outer jacket Aluminium foil and a thermoplastic outer jacket Fluoropolymer outer jacket Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 8 CVR No.: 42 16 59 13

[close]

p. 9

Member of the NIBE Group Selfregulating parallel heating cable Type ELSR-R up to 55°C wi us r b m² pe 6m cop 0.5 ned tin re ing t lat en gu elem e r f l Se ating he u io lat n er pp g co aidin d r e lat ive b -p Tri tect pro Ou ja ter ck et Ins ELSR-R-19-2 output (on insulated metallic pipes in accordance with EN 62395-1) Heating curcuit lengths ELSR-R-19-2 35 30 25 considering • 230V nominal voltage • Delayed action circuit breakers (C-characteristic) with 80 per cent maximum load • Maximum 10 per cent line voltage drop on the heating cable bus wire • A (1) single end power input heating cable into consideration Switch-on temp. °C Nominal cutout value A 16 20 16 20 16 20 16 20 16 20 Heating circuit length (m) for ELSR-R-19-2 95.5 95.5 88 88 82.5 82.5 77.5 77.5 70 70 Heating output [W/m] EL 20 15 SR -R -19 -2 +10ºC 0°C 10 5 0 –30 –20 –10 0 10 20 30 40 50 60 -10˚C -20°C -40°C Pipe temperature [0C] Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 9

[close]

p. 10

Selfregulating heating cable Type ELSR-W up to 100°C Ou te c r ja ke t Pro te on cti Alu m um ini r pe op th c ar ed lat ive e -p Tri tect pro es r wi Ins ul on ati ing t lat en ire gu elem e r sw 2 lf Bu 3mm Se ating 1.2 he • • • • Self-regulating Two nominal outputs Can be cut to length from the roll Moisture proof Applications: The self-regulating heating cable ELSR-W (hot water) is used for receptacles, pipes, valves and several other applications with temperatures between 30°C and approx. 80°C. Except for the connections, the heating cable may be fully immersed. The ELSR-W self-regulating heating cables are frequently used to heat oil and fat lines, for example in the foodstuff industry. But also its use for drainage lines in canteens and (large scale) kitchens makes good sense, avoiding fat and oil deposits by heating. Technical Data: Outer jacket...................................................................... TPE-O Bus wire ......................................................... Cu nickel-plated Maximum exposure temperature (deenergized)...............100°C Maximum exposure temperature (energized).....................80°C Nominal voltage..................................................................230V Bending radius minimum..................................................20mm Min. installation temp....................................................... -20°C Type Nom. loading at 10°C (W/m) 21 21 28 28 Max. allowed ambient temperature power on power off 80 80 80 80 100 100 100 100 Earth braiding Dimensions (mm) Part no. ELSR-W-55-2-AO ELSR-W-55-2-BO ELSR-W-65-2-AO ELSR-W-65-2-BO Design: BO: AO: Alu-foil Braiding Alu-foil Braiding 12.9x5.0 12.9x5.0 12.9x5.0 12.9x5x0 3660100 3660102 3660105 3660106 Protective braiding and a thermoplastic outer jacket. Aluminium foil and a thermoplastic outer jacket. Termination Kit ELSR-W-55/65 ELSR-W-55/65 ELSR-W-55/65 Description For box w/PG16 For box w/M25 For cold cable Part no. 7399106 7399116 7399108 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 10 CVR No.: 42 16 59 13

[close]

p. 11

Member of the NIBE Group Selfregulating heating cable Type ELSR-W up to 100°C ire sw 2 Bu 3mm 1.2 ing t lat en gu elem e r lf Se ating he u Ins lat ion r pe op iding c ra ed lat ive b -p Tri tect pro r ute jac ke t O 70 ELSR-W output (on insulated metallic pipes in accordance with EN 62395-1) Heating output [W/m] 60 50 40 30 20 10 0 -30 –20 –10 0 10 20 30 40 50 60 70 80 90 ELSR ELSR -W-6 5 -W-5 5 Pipe temperature [0C] Heating circuit lengths ELSR-W considering • 230V nominal voltage • Delayed action circuit breakers (C-characteristic) with 80% maximum load • Maximum 10% line voltage drop on the heating cable bus wire • A (1) single end power input heating cable into consideration Switch-on temperature (°C) +50ºC Nominal cutout value (A) 16 20 25 Heating circuit length (m) for ELSR-W-55 ELSR-W-65 158.0 225.0 285.0 121.0 150.0 189.0 106.0 130.0 166.0 96.0 120.0 150.0 110.0 137.0 171.0 76.0 95.0 118.0 63.0 78.0 98.0 54.0 67.0 84.0 +20°C 16 20 25 0ºC 16 20 25 -20°C 16 20 25 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 11

[close]

p. 12

Selfregulating heating tape Type GTe up to 85°C l na et. tio ck Op ter ja ou d ne Tin id a r b p co pe r s ela tic n s o la op ulati erm r ins h T e tom ve cti ix. du matr n -co g mi itin Se lf-lim se pCo s m² wire m 1.1 r bus pe Roof and gutter protection from snow and ice build up • • • • • • Automatically adjusts heat output in response to changes in ambient temperature Can be cut-to-length with no wastage Will not overheat or burnout, even when overlapped Full range of accessories available Optional fluoropolymer outer jacket for use in corrosive environments Available for 110-120VAC and 220-277 VAC Design and installation of a G-Trace system is simple as there are no fixed lengths. The heating tape can be cut to length during installation. G-Trace is cut off the reel and placed in the gutter. The heating tape is hung down into the down pipe without the need for spacers. All systems - from the simplest to the most elaborate – use the same components, thereby providing maximum flexibility and ease of design. Max temperature.................................................................85ºC Minimum installation temp................................................ -40ºC ........................................................................(CENEL -20°C) Power supply................................... 110-120VAC, 220-277VAC Max. resistance of protective braiding. .................18.2 Ohm/km Weight & dimensions Type Ref GTe Nom. Dims. (mm) 10.5 x 5.9 Weight kg/100m 10.0 Min. bending radius 35mm Description: Snow that has built up on a roof will start to melt as a result of either exposure to the sun or from heat rising from the building below. As the melted snow runs from the roof into cold gutters and drain pipes, it can re-freeze forming layers of ice that can continue to build up until the flow is blocked. This can result in damaged drains and gutters. In addition, water can get into the roof and walls of the building, leading to expensive structural damage such as broken roof tiles, damaged plaster and facades, etc. The Solution We have the solution in the form of G-Trace. The self-regulating characteristics of the heating tape means that the cable can adjust it’s heat output in accordance with the ambient temperature. In snow and icy water, the heating cable operates at full power. As the snow melts and the water drains away, GTrace self-regulates to half power while it dries. As it gets warmer, so G-Trace gradually reduces it’s output. The G-Trace system is safe and reliable. As self-regulation prevents overheating, G-Trace can even be installed in plastic gutters and with the UV resistant outer jacket, the heating cable is protected from the sun’s harmful rays – thus making it totally durable and reliable. G-Trace provides a cost effective, preventive maintenance solution to damaged roof tops and gutters and the system consumes no more power than it takes to prevent ice formation. Power Output In ice at 0°C. .................................................................... 36W/m In air at 0°C..................................................................... 18W/m Cold Start Data (300 Second Rating) Start at °C Start Current (A/m) 230V -20°C 0°C +10°C 0.272 0.212 0.180 Accessories We supply a complete range of accessories including termination/splice kits, end seals, junction boxes and controls. THese items are recommended for the correct operation of G-Trace heaters. Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 12 CVR No.: 42 16 59 13

[close]

p. 13

Member of the NIBE Group Selfregulating heating tape Type GTe up to 85°C pCo s m² wire m 1.1 r bus pe ve cti ix. du matr n -co g mi itin Se lf-lim se s ela tic n s o la op ulati erm r ins h T e tom ne Tin id r ba o dc pp er l na et. tio ck Op ter ja ou Maximum Length (m) vs. Circuit breaker size The following circuit details relate specifically to the trace heating of pipework and equipment. For any other application consult SAN. Cat Ref GTe Start-up Temp. 10ºC 0ºC -20ºC 230V 6A 34 28 22 10A 16A 20A 30A 56 48 36 88 76 58 92 92 74 92 Thermal ratings Nominal output at rated voltage. For use with Type C circuit breakers to IEC60898:1991 Power Output Multiplying Factors 230V Heating Tape 200V 208V 220V 230V 240V 250V 277V Multiply output by 0.91 Multiply output by 0.93 Multiply output by 0.97 Multiply output by 1.00 Multiply output by 1.03 Multiply output by 1.06 Multilply output by 1.15 Notes: 1. In snow and ice water, the heating tape will operate at full power. 2. As the snow begins to melt and the water drains away, the heating tape self-regulates to half power while it dries. 3. As it gets warmer, the heating tape will reduce its power output. Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 13

[close]

p. 14

Selfregulating heating tape Type ELSR-H up to 210°C rj ve a e ck t id, bra r e tiv pe tec cop Pro ned tin la su t ion ing t lat en gu elem e r f l Se ating he m² 3m e 1.2 s wir bu O In High Temperature The versatile self-regulating heating cable ELSR-H is for high temperatures up to 210 °C in a large number of industrial applications. It also suited and approved for use in hazardous areas. The BOT version of this heating cable even withstands aggressive chemicals, oil and fuel and, thanks to this high chemical resistance, stands out for a long life span. • • • • • • • Up to 120 °C/210 °C Self-regulating Six nominal outputs Can be cut to length off the roll Moisture proof Resistant to chemicals Approved for use in hazardous areas Applications: • Chemical & petrochemical industries • Oil & gas industry • Power plants • Ex-areas • Frost protection • Water & sanitation utilities • Temperature maintenance on vessels, pipes & valves Technical Data Outer jacket...........................................................Flouropolymer Bus wire. ..................................................... nickel-plated copper Maximum exposure temperature (deenergized)............... 210°C Maximum operating temperature (energized)................... 120°C Nominal voltage....................................................... 230V/120V* (*upon request) Minimum installationtemp................................................. -45°C Minimum bending radius. ................................................. 25mm Classification..................... II 2G Ex e IIC Gb II 2D Ex tb IIIC Db Certificate.................................................... IECEx EPS 12.0004 IMPORTANT! This cable can be produced and delivered for hazardous areas (Ex-area, with ATEX certificate) - please state when ordering. Type ELSR-H-10-2-BOT ELSR-H-15-2-BOT ELSR-H 20-2-BOT ELSR-H 30-2-BOT ELSR-H 45-2-BOT ELSR-H 60-2-BOT Nom. loading at 10°C (W/m) 10 15 20 30 45 60 Dimensions (mm) 12,4x5,0 12,4x5,0 12.4x5.0 12.4x5.0 12.4x5.0 12.4x5.0 Weight approx. (g/m) 120 120 120 120 120 120 Part no. 3663020 3663030 3663045 3663060 BOT: Protective braiding and a fluoropolymer outer jacket. Termination Kit ELSR-H-10/20/30/45/602-BOT ELSR-H-10/20/30/45/602-BOT Description w/plastic gland M25 For cold cable Part no. 7399021 7399108 EX-termination Kit ELSR-H-10/20/30/45/602-BOT Description w/2 brass gland M20 for 2 boxes with earth Part no. 7399020 Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com 14 CVR No.: 42 16 59 13

[close]

p. 15

Member of the NIBE Group Selfregulating heating tape Type ELSR-H up to 210°C m² 3m e 1.2 s wir bu ing t lat en gu elem e r lf Se ating he t ula ion id, bra r e tiv pe tec cop Pro ned tin r ute jac ke t Ins O ELSR-H output (on insulated metallic pipes in accordance with EN 62395-1) Heating output [W/m] 70 Heating circuit lengths ELSR-H-...-2-BOT on the following conditions: • • • 60 • 230V nominal voltage Delayed action circuit breakers (C-characteristic) with 80 per cent maximum load Maximum 10 per cent line voltage drop on the heating cable bus wire A (1) single end power input heating cable into consideration Nominal cutout value (A) 16 20 25 32 16 20 25 32 16 20 25 32 16 20 25 32 16 20 25 32 Heating circuit length (m) for at 230V ELSR- ELSR- ELSR- ELSR- ELSR- ELSRH-10 H-15 H-20 H-30 H-45 H-60 193.0 193.0 193.0 193.0 189.0 189.0 189.0 189.0 184.0 184.0 184.0 184.0 180.0 180.0 180.0 180.0 173.0 173.0 173.0 173.0 158.0 158.0 158.0 158.0 153.0 153.0 153.0 153.0 146.0 148.5 148.5 148.5 139.0 145.0 145.0 145.0 126.0 138.0 138.0 138.0 122.0 136.0 136.0 136.0 116.0 132.0 132.0 132.0 110.0 129.0 129.0 129.0 104.0 125.5 125.5 125.5 95.0 119.0 120.0 120.0 82.0 102.0 111.0 111.0 77.0 97.0 108.0 108.0 73.0 92.0 105.5 105.5 70.0 87.0 103.0 103.0 64.0 80.0 98.0 98.0 55.0 68.0 85.0 91.0 52.0 65.0 81.0 88.5 50.0 62.0 77.0 86.5 47.0 59.0 74.0 84.5 43.0 54.0 68.0 81.0 41.0 51.0 64.0 79.0 39.0 49.0 61.0 77.0 37.0 46.0 58.0 70.0 36.0 44.0 56.0 67.0 33.0 41.0 51.0 61.0 Switchon temp. (°C) 50 EL SR -H 60 10 40 EL SR -H 0 45 -10 30 ELS 20 R-H 30 -20 10 -H 15 ELSR-H 10 ELSR ELSR -H 20 -25 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 Pipe temperature (°C). Gillelejevej 30b - DK-3230 Graested - Denmark Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 98 - info@san-as.com - www.san-as.com CVR No.: 42 16 59 13 15

[close]