Caledonian Industrial Cables German Standard (VDE) CaledonianCables CablesLtd Ltd Caledonian Industrial Cables Cables Industrial German Standard Addison Addison 1 www.cabledatasheet.com 07.03.2015

[close]

p. 2

Addison Industrial Cables Company Profile German Standard (VDE) Caledonian. established in 1978.offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products. . Our superior products provide leading edge within every cable series and for every application. Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard. ISO Standard etc. Caledonian Cables offers a comprehensive stock of cables and cabling products through its nationwide network of resellers and distributors. Caledonian Cables has continually expanded its global presence in Europe and Asia. Caledonian & Addison. produces a wide range of cables for communication. power and electronics in its primary plants in UK. Italy and Spain. To stay in front. we continually keep expanding our manufacturing capabilities in more low cost region such as Romania. Taiwan. Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible. scalable global system that delivers superior operational performance and optimal results for our customers. Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing. logistic services. and vertically integrated with our E commerce technologies. to optimize customer operations by lowering costs and reducing time to market. Caledonian & Addison has been respected for its high standards of quality. excellent service level. competitive pricing and a unique and innovative spirit. With our latest technologies. we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning. we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized. country and industryspecific solutions. Caledonian & Addison has established an extensive network of design. manufacturing. and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers. 2 www.cabledatasheet.com 07.03.2015

[close]

p. 3

Caledonian Industrial Cables Our Certificate German Standard (VDE) www.cabledatasheet.com 07.03.2015 3

[close]

p. 4

Addison Industrial Cables German Standard (VDE) Table of Content H03VV-F/ H03VVH2-F............................................................................ 8 H03V2V2-F/ H03V2V2H2-F.................................................................. 10 H05VV-F/ H05VVH2-F.......................................................................... 12 H05V2V2-F/ H05V2V2H2-F.................................................................. 14 H05VVH6-F/ H07VVH6-F. ..................................................................... 16 H05VV-F/SJT. ........................................................................................ 18 H05RN-F/H05RNH2-F. .......................................................................... 20 H05RR-F............................................................................................... 22 H07RN-F............................................................................................... 24 A07RN-F............................................................................................... 27 H07RN8-F............................................................................................. 29 H05BN4-F............................................................................................. 32 H07BN4-F WIND90............................................................................... 34 H05V-K.................................................................................................. 37 H07V-K.................................................................................................. 38 H05V-K UL / H07V-K UL - UL/CSA/HAR/MTW & UL1015 PVC............ 40 H05V2-K / H07V2-K.............................................................................. 42 H05V2-K UL / H07V2-K UL................................................................... 44 H05V-U / H07V-U.................................................................................. 46 H05V2-U / H07V2-U.............................................................................. 48 H07ZZ-F................................................................................................ 50 (H)03 Z1Z1-F/(H)05 Z1Z1-F.................................................................. 52 H05V-R/H07V-R.................................................................................... 54 4 www.cabledatasheet.com 07.03.2015

[close]

p. 5

Caledonian Industrial Cables German Standard (VDE) H05Z-K / H07Z-K. .................................................................................. 56 H05Z-U / H07Z-U / H07Z-R. .................................................................. 58 H05BQ-F / H07BQ-F (NGMH11YÖ). ..................................................... 60 H05G-K / H07G-K................................................................................. 62 H05G-U / H07G-U................................................................................. 64 H05VV5-F. ............................................................................................. 66 H05VVC4V5-K...................................................................................... 69 H05VVD3H6-F...................................................................................... 72 H05V3V3H6-F/H05V3V3D3H6-F.......................................................... 73 H05BB-F/H07BB-F................................................................................ 75 H03RT-H. ............................................................................................... 77 H05SS-F/H05SST-F.............................................................................. 78 H05GG-F............................................................................................... 80 H00V-D.................................................................................................. 82 H01N2-D/E (NSKFFÖU). ....................................................................... 84 YY. ......................................................................................................... 86 YY LSZH. ............................................................................................... 89 CY Screened Cable. .............................................................................. 92 CY LSZH Screened Cable ................................................................... 95 SY Steel Wire Braid Cable.................................................................... 98 LiYY..................................................................................................... 102 LiYY TP............................................................................................... 106 LiYCY.................................................................................................. 108 www.cabledatasheet.com 07.03.2015 5

[close]

p. 6

Addison Industrial Cables German Standard (VDE) LiYCY TP..............................................................................................112 LiYCY CY.............................................................................................116 Li2YCY/Li2YCYv..................................................................................119 Li2YCY PiMF....................................................................................... 121 LiHH.................................................................................................... 124 LiHCH.................................................................................................. 127 LiHCH TP............................................................................................ 130 JE-LiHCH. ............................................................................................ 133 LiY / LiYv / LiYv-t. ................................................................................. 135 LiYW.................................................................................................... 137 LiFY..................................................................................................... 139 NYM-J / NYM-O. .................................................................................. 141 (N)YM(St)-J......................................................................................... 143 NYY..................................................................................................... 147 NYCY. .................................................................................................. 150 NYCWY............................................................................................... 153 NHXMH/(N)HXMH(St)......................................................................... 156 NAYY................................................................................................... 159 NAYCY................................................................................................ 161 N2XH................................................................................................... 163 N2XY................................................................................................... 168 N2XCY. ................................................................................................ 171 N2XRY. ................................................................................................ 174 N2XFGY.............................................................................................. 177 Product Symbols.......................................................................... 181-184 6 www.cabledatasheet.com 07.03.2015

[close]

p. 7

Caledonian Industrial Cables German Standard (VDE) Conductor Structure....................................................................... 185-189 Conductor Resistance........................................................................... 190 Colour Code................................................................................. 191-196 Fire Performance. ......................................................................... 197-202 www.cabledatasheet.com 07.03.2015 7

[close]

p. 8

Addison Industrial Cables German Standard (VDE) H03VV-F/ H03VVH2-F Application and Description These cable types are especially suited for use on small appliances with low mechanical stress and for connection for light household appliances, e.g. kitchen utensils, desk lamps, floor lamps, vacuum cleaners, office machines, radios, etc. As far as these cables are admitted to the relevant specifications of the equipment, They are not permitted for use with cooking or heating apparatus. Cables with cross section 0.75 mm² are not suitable for outdoor use or use of industrial or farmer machineries. Max operating voltage in single or three phase system is Uo/U 330/330 volts. In a direct current system max operating voltage is Uo/U 495/495 volts. PVC insulation Bare copper conductor PVC outer jacket H03VV-F H03VV-F Standard and Approval HD21.5, VDE 0281, CE low voltage directive 73/23/EEC & 93/68/EEC.ROHS compliant PVC insulation Bare copper conductor PVC outer jacket H03VVH2-F H03VVH2-F 8 www.cabledatasheet.com 07.03.2015

[close]

p. 9

Caledonian Industrial Cables German Standard (VDE) Cable Construction - Bare copper fine wire conductor - Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383 - PVC core insulation T12 to VDE-0281 Part 1 - Color coded to VDE-0293-308 - Green-yellow grounding (3 conductors and above) - PVC outer jacket TM2 Technical Characteristics - Working voltage: 300/300 volts - Test voltage: 2000 volts - Flexing bending radius: 7.5 x Ø - Static bending radius: 4 x Ø - Flexing temperature: -5º C to +70º C - Static temperature: -40º C to +70º C - Short circuit temperature: +160º C - Flame retardant: IEC 60332.1 - Insulation resistance: 20 MΩ x km Cable Parameter AWG No. of Cores x Nominal Cross Sectional Area # x mm² 2 x 0.50 3 x 0.50 4 x 0.50 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 2 x 0.50 2 x 0.75 Nominal Thickness of Insulation mm 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Nominal Thickness of Sheath mm H03VV-F 0.6 0.6 0.6 0.6 0.6 0.6 0.6 H03VVH2-F 0.6 0.6 Nominal Overall Diameter mm 5 5.4 5.8 5.5 6 6.5 7.1 3.2 x 5.2 3.4 x 5.6 Nominal Copper Weight kg/km 9.6 14.4 19.2 14.4 21.6 28.8 36.0 9.7 14.4 Nominal Weight kg/km 38 45 55 46 59 72 87 32 35 20(16/32) 20(16/32) 20(16/32) 18(24/32) 18(24/32) 18(24/32) 18(24/32) 20(16/32) 18(24/32) www.cabledatasheet.com 07.03.2015 9

[close]

p. 10

Addison Industrial Cables German Standard (VDE) H03V2V2-F/ H03V2V2H2-F Application and Description These cables are suitable for domestic premises, kitchen, office for light service or light portable apparatuses. With their special insulation and sheath compounds these cables are adapt for apparatus in kitchen and heating and for use in zones with high temperatures (like lighting system apparatuses) without contact with warm parts and radiations. Unsuitable for outdoor use, in industrial and agricultural buildings or non-domestic portable tools. The maximum conductor temperature in normal use: 90°C.While high temperature use, skin contact must be avoided Yellow/Green wire PVC insulation Bare copper conductor PVC outer jacket H03V2V2-F H03V2V2-F Standard and Approval HD 21.12; HD 308 S2 DIN VDE 0281 part 1, part 12; DIN VDE 0293 part 308; DIN VDE 0295 PVC insulation Bare copper conductor PVC outer jacket H03V2V2H2-F H03V2V2H2-F 10 www.cabledatasheet.com 07.03.2015

[close]

p. 11

Caledonian Industrial Cables German Standard (VDE) Cable Construction - Bare copper fine wire conductor - Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383 - PVC core insulation T13 to VDE-0281 Part 1 - Color coded to VDE-0293-308 - PVC outer jacket TM3 Technical Characteristics - Working voltage: 300/300 volts - Test voltage: 3000 volts - Flexing bending radius: 15 x Ø - Static bending radius: 4 x Ø - Flexing temperature: +5º C to +90º C - Static temperature: -40º C to +90º C - Short circuit temperature: +160º C - Flame retardant: IEC 60332.1 - Insulation resistance: 20 MΩ x km Cable Parameter AWG No. of Cores x Nominal Cross Sectional Area # x mm² 2 x 0.50 3 x 0.50 4 x 0.50 2 x 0.75 3 x 0.75 4 x 0.75 2 x 0.50 2 x 0.75 Nominal Thickness of Insulation mm 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Nominal Thickness of Sheath mm H03V2V2-F 0.6 0.6 0.6 0.6 0.6 0.6 H03V2V2H2-F 0.6 0.3 Nominal Overall Diameter mm 5 5.4 5.8 5.5 6 6.5 3.2 x 5.2 3.4 x 5.6 Nominal Copper Weight kg/km 9.6 14.4 19.2 14.4 21.6 28.8 9.7 14.4 Nominal Weight kg/km 38 45 55 46 59 72 32 35 20(16/32) 20(16/32) 20(16/32) 18(24/32) 18(24/32) 18(24/32) 20(16/32) 18(24/32) www.cabledatasheet.com 07.03.2015 11

[close]

p. 12

Addison Industrial Cables German Standard (VDE) H05VV-F/ H05VVH2-F Application and Description These cables are suited for medium mechanical stress in damp and wet environments such as refrigerators, washing machines, spin dryers and other appliances, as long as it meets applicable equipment specifications. These cables are also suited for cooking and heating apparatus, provided that the cable does not come into direct contact with the hot parts of the apparatus or with any other heat source. Further applications of this cable include: Fixed installation in furniture, partition walls, decorative covering, and in the hollow spaces of prefabricated building parts. They are not suitable for outdoor use, industrial (except clothing manufacture) or farming applications. Max operating voltage in single or three phase system is Uo/U 318/550 volts. In a direct system, max operating voltage is Uo/U 413/825 volts. Standard and Approval VDE0281, CENELEC HD21.5, CE low voltage directive 73/23/EEC & 93/68/EEC., ROHS compliant 0.5 - 2.5mm² to BS6500, 4.0mm² to BS7919, 6.0mm² generally to BS7919, Cable Construction - Bare copper fine wire conductor - Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383 - PVC core insulation T12 to VDE-0281 Part 1 - Color coded to VDE-0293-308 - Green-yellow grounding (3 conductors and above) - PVC outer jacket TM2 Technical Characteristics - Working voltage: 300/500 volts - Test voltage: 2000 volts - Flexing bending radius: 7.5 x Ø - Static bending radius: 4 x Ø - Flexing temperature: -5º C to +70º C - Static temperature: -40º C to +70º C - Short circuit temperature: +160º C - Flame retardant: IEC 60332.1 - Insulation resistance: 20 MΩ x km H05VV-F PVC outer jacket Green/Yellow wire Bare copper conductor PVC insulation H05VV-F 12 www.cabledatasheet.com 07.03.2015

[close]

p. 13

Caledonian Industrial Cables German Standard (VDE) PVC insulation Bare copper conductor PVC outer jacket H05VVH2-F Cable Parameter AWG No. of Cores x Nominal Cross Sectional Area # x mm² 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 2 x 1.00 3 x 1.00 4 x 1.00 5 x 1.00 2 x 1.50 3 x 1.50 4 x 1.50 5 x 1.50 2 x 2.50 3 x 2.50 4 x 2.50 5 x 2.50 3 x 4.00 4 x 4.00 5 x 4.00 3 x 6.00 4 x 6.00 2 x 0.75 2 x 1.00 Nominal Nominal Thickness of Thickness Insulation of Sheath mm mm H05VV-F 0.6 0.8 0.6 0.8 0.6 0.8 0.6 0.9 0.6 0.8 0.6 0.8 0.6 0.9 0.6 0.9 0.7 0.8 0.7 0.9 0.7 1.0 0.7 1.1 0.8 1.0 0.8 1.1 0.8 1.1 0.8 1.2 0.8 1.2 0.8 1.2 0.8 1.4 0.8 1.1 0.8 1.3 H05VVH2-F 0.6 0.8 0.6 0.8 Nominal Overall Diameter mm 6.4 6.8 7.4 8.5 6.8 7.2 8.0 8.8 7.6 8.2 9.2 10.5 9.2 10.1 11.2 12.4 11.3 12.5 13.7 13.1 13.9 4.2 x 6.8 4.4 x 7.2 H05VVH2-F Nominal Copper Weight kg/km 14.4 21.6 29 36 19 29 38 48 29 43 58 72 48 72 96 120 115 154 192 181 230 14.4 19.2 Nominal Weight kg/km 57 68 84 106 65 79 101 123 87 111 142 176 134 169 211 262 233 292 369 328 490 48 57 18(24/32) 18(24/32) 18(24/32) 18(24/32) 17(32/32) 17(32/32) 17(32/32) 17(32/32) 16(30/30) 16(30/30) 16(30/30) 16(30/30) 14(50/30) 14(50/30) 14(50/30) 14(50/30) 12(56/28) 12(56/28) 12(56/28) 10(84/28) 10(84/28) 18(24/32) 17(32/32) www.cabledatasheet.com 07.03.2015 13

[close]

p. 14

Addison Industrial Cables German Standard (VDE) H05V2V2-F/ H05V2V2H2-F Application and Description These cables are suitable for domestic premises, kitchen, office for light service or light portable apparatuses. With their special insulation and sheath compounds these cables are adapt for apparatus in kitchen and heating and for use in zones with high temperature (like lighting system apparatuses) without contact with warm parts and radiations. Unsuitable for outdoor use, in industrial and agricultural buildings or non-domestic portable tools. The maximum conductor temperature in normal use: 90°C. While high temperature use, skin contact must be avoided Standard and Approval HD 21.12; HD 308 S2, DIN VDE 0281 part 1, part 12, DIN VDE 0293 part 308, DIN VDE 0295 Cable Construction - Bare copper fine wire conductor - Stranded to DIN VDE 0295 cl. 5, IEC 60228 cl. 5 and HD 383 - PVC core insulation T13 to VDE-0281 Part 1 - Green-yellow grounding (3 conductors and above) - Color coded to VDE-0293-308 - PVC outer jacket TM3 Technical Characteristics - Working voltage: 300/500 volts - Test voltage: 2000 volts - Flexing bending radius: 15 x Ø - Static bending radius: 4 x Ø - Flexing temperature: +5º C to +90º C - Static temperature: -40º C to +90º C - Short circuit temperature: +160º C - Flame retardant: IEC 60332.1 - Insulation resistance: 20 MΩ x km H05V2V2-F PVC outer jacket Green/Yellow wire Bare copper conductor PVC insulation H05V2V2-F 14 www.cabledatasheet.com 07.03.2015

[close]

p. 15

Caledonian Industrial Cables German Standard (VDE) PVC insulation Bare copper conductor PVC outer jacket H05V2V2H2-F Cable Parameter AWG No. of Cores x Nominal Cross Sectional Area # x mm² 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 2 x 1.00 3 x 1.00 4 x 1.00 5 x 1.00 2 x 1.50 3 x 1.50 4 x 1.50 5 x 1.50 2 x 2.50 3 x 2.50 4 x 2.50 5 x 2.50 3 x 4.00 4 x 4.00 5 x 4.00 3 x 6.00 4 x 6.00 2 x 0.75 2 x 1.00 Nominal Nominal Thickness of Thickness Insulation of Sheath mm mm H05V2V2-F 0.6 0.8 0.6 0.8 0.6 0.8 0.6 0.9 0.6 0.8 0.6 0.8 0.6 0.9 0.6 0.9 0.7 0.8 0.7 0.9 0.7 1.0 0.7 1.1 0.8 1.0 0.8 1.1 0.8 1.1 0.8 1.2 0.8 1.2 0.8 1.2 0.8 1.4 0.8 1.1 0.8 1.3 H05V2V2H2-F 0.6 0.8 0.6 0.8 Nominal Overall Diameter mm 6.2 6.6 7.1 8 6.4 6.8 7.6 8.3 7.4 8.1 9 10 9.2 10 10.9 12.4 11.3 12.5 13.7 13.1 13.9 4.2 x 6.8 4.4 x 7.2 H05V2V2H2-F Nominal Copper Weight kg/km 14.4 21.6 29 36 19 29 38 48 29 43 58 72 48 72 96 120 115 154 192 181 230 14.1 19 Nominal Weight kg/km 54.2 65 77.7 97.3 60.5 73.1 93 111.7 82.3 104.4 131.7 163.1 129.1 163 199.6 245.4 224 295 361 328 490 48 57 18(24/32) 18(24/32) 18(24/32) 18(24/32) 17(32/32) 17(32/32) 17(32/32) 17(32/32) 16(30/30) 16(30/30) 16(30/30) 16(30/30) 14(50/30) 14(50/30) 14(50/30) 14(50/30) 12(56/28) 12(56/28) 12(56/28) 10(84/28) 10(84/28) 18(24/32) 17(32/32) www.cabledatasheet.com 07.03.2015 15