Digitally Controlled Ferroresonant Inverter

Popular Pages


p. 1

Digitally Controlled Ferroresonant Inverter DSS SINGLE PHASE INDUSTRIAL INVERTER

[close]

p. 2

DSS Digitally Controlled Ferroresonant Industrial Inverter Single Phase 3-50 kVA The DSS Inverter from AMETEK Solidstate Controls combines the best of both worlds – • The reliability and robust design of a Ferroresonant Inverter • The digital control and communications typically found only in PWM products.  he DSS is a true on-line, Inverter system  T that provides continuous, clean, regulated power for critical AC loads. Designed  specifically for process control and harsh industrial applications, the DSS combinesdigital control for enhanced communications, monitoring, control and  diagnostics capabilities with proven ferroresonant transformer design. T  he DSS also includes the LCD panel and user-friendly touch screen display found in our Digital Process Power systems for the ultimate in user control. Benefits of the DSS: • AMETEK SCI’s ferroresonant design (over 50 years of proven reliability) • High MTBF - exceeds 205,000 hours (23 Years) • Industrial grade - built to operate in extreme environments • Vacuum pressure impregnated (VPI) magnetics with 200ºC epoxy insulation (Class N)  • Long life LED indicators, front panel accessibility  • Unique crest factor circuitry provides full capacity for non-linear loads • All components are front accessible-no side or back clearance required  Integral system event recording for diagnostics (logs last 500 events)  - Lighted Mimic Panel Display • Microprocessor based alarms The Power Behind the Process Keypad Controls and Switches PROCESSPOWER INVERTER LCD and Touch Screen User Panel Inverter to Load w/Light Bypass to Load w/Light Static Switch Reset Retransfer Latching Alarm Reset Audible Alarm Silence Display On Inverter Enable (On/Off) Switch *Standard LED Indicators: Inverter Normal and Inverter Trouble Standard Mimic Screen (LCD Panel) Indicators Inverter Status (OK/Fail) Synchronism Status (In/Out of Sync) Static Switch Position (Inverter or Bypass) Manual Bypass Position (Inverter or Bypass) Bypass Status (OK/Fail) Shown with optional indicator lights

[close]

p. 3

General Specifications – Standard Features System Measurements (Displayed on Mimic Screen) Total Number of Battery Discharges Total Operational Time on Batteries Average Time on Battery per Discharge Historical Min/Max Battery Voltage Recent Min/Max Battery Voltage Total Operation Time on Bypass Total Operation Time on Inverter Metering (Displayed on Mimic Screen) DC Bus Voltage DC Bus Current (+/-) AC Output Voltage AC Output Current AC Output Frequency Circuit Breakers DC Input (10kAIC, minimum) Bypass Input (14kAIC, minimum) General Specifications – Optional Features Metering and System Measurements (Option #) Bypass Input Frequency (112) Bypass Input Voltage (113) Output Power (kVA, KW, Power Factor) (114) % Inverter Loading (115) Inverter Output Voltage (117) Analog Meters (196) Circuit Breaker (Option #) 65 KAIC Bypass Breaker (85) Inverter Output (Non-Automatic) (17) AC Output (18) DC High Interrupt Breaker (86) Communications (Option #) Modbus RTU (RS485 Connection) (187) Ethernet Webpage (187) Modbus TCP (187) SCI-Link Consult Factory for Additional Communication Options Miscellaneous (Option #) Cascade Redundant Configuration Additional Relay Contacts (Max of 13 available) Additional LED Indicators(1 green, 9 red available) Remote External MBS1 Miscellaneous – Continued (Option #) Latching Alarms (28) Lamp Test (35) Alarm Relay Test (132) Alarms (Option #) High DC Disconnect (2) Positive/Negative to Ground (2 relays) (3) High/Low Bypass Source Voltage (7/6) High/Low AC Output Voltage (9/8) AC Output Overload (48) High/Low Inverter Output Voltage (41/42) Out-of-Sync (43) Inverter Fuse Blown (44) Inverter Off Frequency (45) Bypass Off Frequency (46) Battery Near Exhaustion (60) High DC Voltage (5) MBS to Bypass (78) Bypass Input CB Open (103) AC Output CB Open (104) Alarms (Displayed on LCD Alarm Panel) Fan Failure Low DC Voltage Low DC Disconnect DC Breaker Open ST/SW Retransfer Blocked Battery Discharging Overload Shutdown Bypass Supplying Load ST/SW Bridge Over Temperature Inverter Bridge Over Temperature ST/SW SCR Failure Bypass Failure Inverter Failure System Diagnostics (Displayed on LCD Alarm Panel) Loss of System Communication(s) Power Supply Failure(s) Relay Controls The following alarms also include 1 (one) set of normally open and normally closed relay contacts rated for 120VAC at 8 amps (30VDC at 8 amps): Inverter Trouble (Summary) Bypass Supplying Load Inverter Communications Failure (Summary) Applicable Standards, Codes and Regulations NEMA PE-1 ANSI ANSI/NFPA 70 IEEE UL-1778 C-UL ISO9001 Certified Facility General Specifications – Performance Inverter DC Input Nominal Voltage Range/ #of Cells (Lead Acid Type) 120V/60 (105-140VDC) 240V/120 (210-280VDC) Static Switch Bypass Voltage Switch Type Failure Mode AC Output Inverter/UPS Ratings Power Factor Range AC Output Voltage2 Regulation Frequency Crest Factor Total Harmonic Distortion (THD) Transient Response Recovery Time Overload Capacity 3 - 50 kVA 0.8 - 1.0 120: Single phase, 2 wire 120/240: Single phase, 3 wire ± 2% 60 Hz; ± 0.1% 3:1 100% linear load <5% 23% for ½ cycle 2% after 50 ms < 50 msec to ± 1% 120% - continuous 125% - 10 minutes 150% - 1 minute Positions Construction Transfer Time Overload Capacity Mounting Manual Bypass Switch1 Voltage Transfer Time Sync Capture Range Slew Rate Overload Capability 120 Single Phase, 2-wire 120/240 Single Phase, 3-wire Inversely paired set of SCRs (one set per leg) Automatically fails to Bypass Make Before Break 0.5% to 0.8% adjustable 1Hz/sec to 10Hz/sec (adjustable) 125% continuous 150% for 10 minutes 200% for 1 minute 1000% for 1 cycle 120: Single phase, 2 wire 120/240: Single phase, 3 wire Inside UPS/Inverter Enclosure Two 600VAC, rotary drum, make-before-break type Zero in both directions 125% continuous 150% for 10 minutes 200% for 1 minute 1000% for 1 cycle 0 to 40oC (32 to 104oF) 0-95% non-condensing 0-3300 meters (10,000 feet) 65-72dB(A) @1.5 meter (4.9 feet) typical Aided Convection or Forced Air, depending on kVA rating and design (fans standard for 30kVA units and above) Top and Bottom Entry Standard >205,000 Hours Environmental Ambient Temperature Relative Humidity Operating Altitude Audible Noise3 Cooling Cable Entry Mean Time Between Failure (MTBF) Cabinet Rating NEMA 1 / IP-20 (IP-21 with addition of optional drip shield) 1 Internal Manual Bypass Switch is normally removed when a Remote Manual Bypass Switch is selected 2 Custom Input and Output Voltages available – Consult Factory 3 Addition of drip shield may increase the noise by 1-3dB(A)

[close]

p. 4

120VDC (60 Lead Acid Battery Cells) Model DSS003-** DSS005-** DSS007-** DSS010-** DSS015-** DSS020-** DSS030-** DSS040-** DSS050-** Rated Output Power KVA 3 5 7.5 10 15 20 30 40 50 KW 3 5 7.5 10 15 20 30 40 50 Efficiency DC-AC 83% 85% 85% 85% 86% 86% 87% 88% 88% Max DC Current 1.75VPC 34 56 84 112 166 221 328 432 541 AC Output Amps* 120 25 42 63 83 125 167 250 333 417 240 13 21 31 42 63 83 125 167 208 UPS Cabinet Style GTD1X GTD1X GTD1X GTD1X GTD1X GTD1X GTD1X GTD1X GTD2X DC I/P Breaker 120 50 70 100 125 200 250 400 500 600 Bypass Breaker 120 35 60 80 125 175 225 350 500 600 120/240 20 30 40 60 80 110 175 225 300 Lbs. 885 885 1100 1325 2050 2100 2650 3050 3700 Weight Kg. 402 402 500 602 932 955 1205 1386 1682 2097 3011 4516 6021 8332 11109 15295 18611 23264 Heat Loss (BTU) 240VDC (120 Lead Acid Battery Cells) Model DSS003-** DSS005-** DSS007-** DSS010-** DSS015-** DSS020-** DSS030-** DSS040-** DSS050-** Rated Output Power KVA 3 5 7.5 10 15 20 30 40 50 KW 3 5 7.5 10 15 20 30 40 50 DC-AC 84% 87% 88% 88% 88% 88% 88% 88% 88% Max DC Current 1.75VPC 17 27 41 54 81 108 162 217 270 AC Output Amps* 120 25 42 63 83 125 167 250 333 417 240 13 21 31 42 63 83 125 167 208 UPS Cabinet Style GTD1X GTD1X GTD1X GTD1X GTD1X GTD1X GTD1X GTD1X GTD2X DC I/P Breaker 240 25 40 50 70 100 125 200 250 350 Bypass Breaker 120 35 60 80 125 175 225 350 500 600 120/240 20 30 40 60 80 110 175 225 300 Lbs. 685 685 830 1125 1455 1635 1995 2240 2940 Weight Kg. 311 311 377 511 661 743 906 1017 1335 1950 2549 3490 4653 6979 9305 13958 18611 23264 Heat Loss (BTU) Inches—Cabinet-Dimensions—mm Style GTD1X GTD2X H x W x D 79 x 32 x 36 79 x 54 x 36 H x W x D 2007 x 813 x 914 2007 x 1372 x 914 “EE” DC Bus Volts Code 120 – (12) 240 – (24) “FF” AC Output Volts (Code) 120 – (12) 120/240 - (24) “GG” Freq (Code) 60 – (60) *Circuit Breakers are sized at a minimum of 125% of rated current. **A complete model number includes the DC bus (link) voltage, AC output voltage and system frequency. To “build” a model number, use the “code” in the matrix shown above, following the example format: DSS020-EE-FF-GG; where EE=DC bus voltage; FF=AC Output Voltage; GG=System Frequency. For Example: A 20 kVA with 120 VDC bus voltage; 120 VAC output, 60 Hz frequency; would have the following model number: DSS020-12-12-60. For 120/240 VAC output units, add “2” before DSE model number For custom systems, and for units which do not have a configurable model number, insert a ‘C’ in the model number as follows: DSS020C Specifications are subject to change. Top mounted cooling fans require 13mm (0.5 in) additional height. Certain optional features and/or combinations may require larger cabinets. For serious inquiries, please contact factory.

[close]

p. 5

T HE PURPO SE OF OUR BUSINESS I S T O P ROVI D E CONT I NU I T Y OF E L E CT RIC A L P O W ER TO KEEP BU SI N E SSE S I N BU SI N E SS All Facilities are ISO 9001 Certified World Headquarters Asia Pacific Headquarters Middle East Headquarters 875 Dearborn Drive AMETEK Singapore Office AMETEK Solidstate Controls Columbus, Ohio 43085 43 Changi South Ave. 2 #04-01 P.O. Box: 17067 Phone: +1-614-846-7500 Singapore 486164 Jebel Ali F.Z.; Dubai, U.A.E. Toll Free: +1-800-635-7300 Phone: +65-6484-2388 Phone: +971-50-5584054 Fax: +1-614-885-3990 Fax: +65-6481-6588 Alt Phone: +971-50-5720648 Mexico Headquarters Brazil Headquarters India Headquarters Avenida Ejercito Nacional AMETEK do Brasil Ltda Number 423 2o. Colonia Granada Rod. Eng° Ermênio de Oliveira Penteado C.P. 11520 Miguel Hidalgo, Mexico, D.F. (SP75) - Km 57, Barrio Tombadouro Phone: +52-55-5250-1132 Indaiatuba - SP - Brasil, 13337-300 Fax: +52-55-5250-7981 Phone: +55-16-2107-4100 AMETEK Instruments India Private Limited Plot 148, EPIP Zone Phase 2 Featherlite Tech Park, 1st Floor Whitefield, Bangalore - 560066 Karnataka, INDIA Phone: +91 70222 53258 Fax: +91 80 6782 3232 VISIT OUR WEBSITES: English: www.solidstatecontrolsinc.com Nuclear: www.nuclearups.com Spanish: www.solidstatecontrolsinc-esp.com Russian: www.solidstatecontrolsinc-ru.com Chinese: www.solidstatecontrolsinc-chn.com Brazilian Portuguese: www.solidstatecontrolsinc-bz.com

[close]