Digitally Controlled Ferroresonant UPS

Popular Pages


p. 1

Digitally Controlled Ferroresonant UPS DSE SINGLE PHASE INDUSTRIAL UNINTERRUPTIBLE POWER SUPPLY SYSTEM

[close]

p. 2

DSE Digitally Controlled Ferroresonant Industrial Uninterruptible Power Supply System Single Phase 3-50 kVA The DSE UPS from AMETEK Solidstate Controls combines the best of both worlds – • The reliability and robust design of a Ferroresonant UPS • The digital control and communications typically found only in PWM products.  he DSE is a true on-line, double conversion Uninterruptible Power Supply system  T that provides continuous, clean, regulated power for critical AC loads. Designed  specifically for process control and harsh industrial applications, the DSE combinesdigital control for enhanced communications, monitoring, control and  diagnostics capabilities with proven ferroresonant transformer design. T  he DSE also includes the LCD panel and user-friendly touch screen display found in our Digital Process Power systems for the ultimate in user control. Benefits of the DSE: • AMETEK SCI’s ferroresonant design (over 50 years of proven reliability) • High MTBF - exceeds 205,000 hours (23 Years) • Industrial grade - built to operate in extreme environments • Vacuum pressure impregnated (VPI) magnetics with 200ºC epoxy insulation (Class C)  • Long life LED indicators, front panel accessibility  • Unique crest factor circuitry provides full capacity for non-linear loads • All components are front accessible-no side or back clearance required  Integral system event recording for diagnostics (logs last 500 events)  - Lighted Mimic Panel Display • Microprocessor based alarms • 6 or 12 pulse charger available The Power Behind the Process PROCESSPOWER UPS SYSTEM LCD and Touch Screen User Panel Keypad Controls and Switches Float/Equalize Initialization w/Light Battery Test Initialization Inverter to Load w/Light Bypass to Load w/Light Static Switch Reset Retransfer Latching Alarm Reset Audible Alarm Silence Display On Inverter Enable (On/Off) Switch *Standard LED Indicators: UPS Normal and UPS Trouble Standard Mimic Screen (LCD Panel) Indicators Equalize Time Remaining Charger Status (OK/Fail) Float/Equalize Status Inverter Status (OK/Fail) Synchronism Status (In/Out of Sync) Static Switch Position (Inverter or Bypass) Manual Bypass Position (Inverter or Bypass) Bypass Status (OK/Fail) Shown with optional indicator lights

[close]

p. 3

General Specifications – Standard Features System Measurements (Displayed on Mimic Screen) Total Number of Battery Discharges Total Operational Time on Batteries Average Time on Battery per Discharge Historical Min/Max Battery Voltage Recent Min/Max Battery Voltage Total Operation Time on UPS Total Operation Time on Bypass Total Operation Time on Inverter Metering (Displayed on Mimic Screen) DC Bus Voltage DC Bus Current (+/-) AC Output Voltage AC Output Current AC Output Frequency Rectifier Output Current Circuit Breakers AC Input (14kAIC, minimum) Battery Input (10kAIC, minimum) Bypass Input (14kAIC, minimum) Alarms (Displayed on LCD Alarm Panel) Fan Failure Charger Failure Low DC Voltage Low DC Disconnect Battery Breaker Open ST/SW Retransfer Blocked Battery Discharging Overload Shutdown Bypass Supplying Load ST/SW Bridge Over Temperature Inverter Bridge Over Temperature ST/SW SCR Failure Bypass Failure Inverter Failure System Diagnostics (Displayed on LCD Alarm Panel) Loss of System Communication(s) Power Supply Failure(s) Relay Controls The following alarms also include 1 (one) set of normally open and normally closed relay contacts rated for 120VAC at 3 amps (30VDC at 8 amps): UPS Trouble (Summary) Bypass Supplying Load UPS Communications Failure (Summary) Applicable Standards, Codes and Regulations NEMA PE-1 ANSI ANSI/NFPA 70 IEEE UL-1778 C-UL Unit Manufactured in ISO9001 Certified Facility General Specifications – Optional Features Metering and System Measurements (Opt. #) AC Input Power (Voltage , Frequency, Current) (111) Bypass Input Frequency (112) Bypass Input Voltage (113) Output Power (kVA, KW, Power Factor) (114) % Inverter Loading (115) Inverter Output Voltage (117) Analog Meters (10) Circuit Breaker (Opt. #) 65 KAIC AC Input and Bypass Input (82/85) Inverter Output (Non-Automatic) (17) AC Output (18) Battery High Interrupt Breaker (86) Communications (Opt. #) Modbus RTU (RS485 Connection) (187) Ethernet Webpage (187) Modbus TCP (187) SCI-Link (36) Consult Factory for Additional Communication Options Miscellaneous (Opt. #) Rectifier Configuration (34) Charger Output Blocking Diode (29) Charger Output Ripple Filter Cascade Redundant Configuration 12 Pulse Charger (10% Reflected Harmonics) Additional Relay Contacts (Max of 13 allowed) Additional LED Indicators(1 green, 9 red allowed) Remote External MBS1 Miscellaneous – Continued Latching Alarms Lamp Test Alarm Test (Option #) (28) (35) (132) Alarms (Option #) Charger Overload (119) High DC Disconnect (2) Positive/Negative to Ground (2 relays) (3) High/Low Bypass Source Voltage (7/6) High/Low AC Output Voltage (9/8) AC Power Failure (26) AC Output Overload (48) High/Low Inverter Output Voltage (41/42) Out-of-Sync (43) IInverter Fuse Blown (44) Inverter Off Frequency (45) Bypass Off Frequency (46) Rectifier/Charger Fuse Blown Battery Near Exhaustion Low AC Input Voltage High DC Voltage Rectifier/Charger Failure MBS to Bypass AC Input CB Open Bypass Input CB Open AC Output CB Open (67) (60) (68) (5) (69) (78) (101) (103) (104) General Specifications – Performance Battery Charger/Rectifier AC Input Nominal Voltage2 208, 380, 415, 480, 600: 3-phase/ 3- wire Input Range + 10% (-15% w/o discharging) Frequency 50 or 60 Hz + 5% DC Output DC Bus Voltage(s) Regulation Ripple Voltage Capacity 110,120,220, 240 and 360 VDC + 1% <2% w/ battery connected Sized to recharge a thirty (30) min. battery to 95% of its rated capacity within eight (8) hours, while simultaneously supplying power to a fully loaded inverter +5% Adjustability Static Switch Bypass Voltage Switch Type Failure Mode Transfer Time Sync Capture Range Slew Rate Overload Capability 120/208 1-phase, 2-wire Inversely paired set of SCRs (one set per leg) Automatically fails to Bypass Make Before Break 0.5% to 1.5% 1Hz/sec to 10Hz/sec (adjustable) 125% continuous 150% for 10 minutes 200% for 1 minute 1000% for 1 cycle 120/208 : 1-phase, 2-wire Inside UPS/Inverter Enclosure Two 600VAC, rotary drum, make-before-break type Zero in both directions 125% continuous 150% for 10 minutes 200% for 1 minute 1000% for 1 cycle 0 to 40oC (32 to 104oF) 0-95% non-condensing 0-3300 meters (10,000 feet) 65-72dB(A) @1.5 meter typical Aided Convection or Forced Air, depending on kVA rating and design (fans standard for 30kVA units and above) Top or Bottom Entry Standard >205,000 Hours Float/Equalize Inverter DC Input Nominal Voltage Range/ #of Cells (Lead Calcium Type) Manual Bypass Switch1 Voltage Mounting Positions Construction Transfer Time Overload Capacity 120V/60 (105-140VDC) 240V/120 (210-280VDC) AC Input Inverter/UPS Ratings Power Factor AC Output Voltage2 Regulation Frequency Crest Factor Total Harmonic Distortion (THD) Transient Response Recovery Time Overload Capacity 3 - 50 kVA 1.0 120 : 1-phase, 2-wire + 2% 60 Hz; + 0.1% 3:1 100% linear load <5% 23% for ½ cycle 2% after 50 ms < 50 msec to + 1% 120% - continuous 125% - 10 minutes 150% - 1 minute Environmental Ambient Temperature Relative Humidity Operating Altitude Audible Noise3 Cooling Cable Entry Mean Time Between Failure (MTBF) Cabinet Rating NEMA 1 / IP-20 (IP-21 with addition optional drip shield) 1 Internal Manual Bypass Switch is normally removed when a Remote Bypass Switch is selected 2 Custom Input and Output Voltages available – Consult Factory 3 Addition of drip shield may increase the noise by 1-3dB(A)

[close]

p. 4

120VDC (60 Lead Calcium Battery Cells) Model Rated Output Power KVA DSE003-** DSE005-** DSE007-** DSE010-** DSE015-** DSE020-** DSE030-** DSE040-** DSE050-** 3 5 7.5 10 15 20 30 40 50 KW 3 5 7.5 10 15 20 30 40 50 Efficiency AC-DC 91% 91% 91% 92% 93% 93% 94% 94% 94% DC-AC 83% 85% 85% 85% 86% 86% 87% 88% 88% AC Amps per Phase* (AC Input/Freq ) 480/60 10 12 19 24 36 48 72 96 120 208/60 23 29 43 56 83 111 165 220 275 Max DC Current 1.75VPC 34 56 84 112 166 221 328 432 541 AC Output Amps* 120 25 42 63 83 125 167 250 333 417 UPS Cabinet Style GTD1X GTD1X GTD1X GTD1X GTD1X GTD1X GTD2X GTD2X GTD2X AC I/P Circuit Breaker 208 30 35 60 70 125 150 225 300 400 480 15 15 25 30 50 60 90 125 150 Battery I/P Breaker 120 50 70 100 125 200 250 400 500 600 Bypass Breaker 120 35 60 80 125 175 225 350 450 600 Weight Lbs. 885 885 1100 1325 2050 2100 2650 3050 3700 Kg. 402 426 500 62 932 955 1205 1386 1682 3316 4996 7493 9512 12811 17081 22805 28510 35638 Heat Loss (BTU) 240VDC (120 Lead Calcium Battery Cells) Model Rated Output Power KVA DSE003-** DSE005-** DSE007-** DSE010-** DSE015-** DSE020-** DSE030-** DSE040-** DSE050-** 3 5 7.5 10 15 20 30 40 50 KW 3 5 7.5 10 15 20 30 40 50 Efficiency AC-DC 91% 91% 91% 92% 93% 93% 94% 94% 94% DC-AC 83% 85% 85% 85% 86% 86% 87% 88% 88% AC Amps Per Phase* (AC Input/Freq ) 480/60 11 12 20 24 36 48 72 96 120 208/60 23 29 46 56 84 111 165 220 275 Max DC Current 1.75VPC 17 27 41 54 81 108 162 217 270 AC Output Amps* 120 25 42 63 83 125 167 250 333 417 UPS Cabinet Style GTD1X GTD1X GTD1X GTD1X GTD1X GTD1X GTD2X GTD2X GTD2X AC I/P Circuit Breaker 208 30 35 60 70 125 150 225 300 400 480 15 15 25 30 50 60 90 125 150 Battery I/P Breaker 240 25 40 50 70 100 125 200 250 350 Bypass Breaker 120 35 60 80 125 175 225 350 450 600 Weight Lbs. 885 885 1100 1325 2050 2100 2650 3050 3700 Kg. 402 426 500 62 932 955 1205 1386 1682 3155 4489 6366 8024 11357 15142 21383 28510 35638 Heat Loss (BTU) Inches—Cabinet-Dimensions—mm Style GTD1X GTD2X H x W x D 79 x 32 x 36 79 x 54 x 36 H x W x D 2007 x 813 x 914 79 x 54 x 36 Model Coding “DD” AC Input Volts Code 480 – (48) 208 – (20) “EE” DC Bus Volts Code 120 – (12) 240 – (24) “FF” AC Output Volts (Code) 120 – (12) “GG” Freq (Code) 60 – (60) “HH” Output P.F (Code) 1.0 – (W) “I” Charger Design (Code) 6-Pulse – (S) 12-Pulse – (T) “J” Config Code (Code) Float – (F) *Circuit Breakers are sized at a minimum of 125% of rated current. **A complete model number includes the AC input voltage, DC bus (link) voltage, AC output voltage, system frequency, output power factor, and UPS configuration. To “build” a model number, use the “code” in the matrix shown above, following the example format: DPP010-DD-EE-FF-GG-H-I-J; where DD=AC Input Voltage; EE=DC bus voltage; FF=AC Output Voltage; GG=System Frequency; H=Output Power Factor (‘W’ for 1.0); I=6(S) or 12(T) Pulse Charger design; J=UPS configuration (‘F’ for float). For Example: A 20 kVA with 480 volt input; 120 VDC bus voltage; 120 volt output; 60 Hz; 1.0 output power factor; 6=pulse charger; Float system would have the following model number: DSE020-48-12-12-60-W-S-F. For custom systems, and for units which do not have a configurable model number, insert a ‘C’ in the model number as follows: DSE020C Specifications are subject to change. Top mounted cooling fans require 13mm additional height. Certain optional features and/or combinations may require larger cabinets. For serious inquiries, please contact factory.

[close]

p. 5

All Facilities are ISO 9001 Certified World Headquarters Asia Pacific Headquarters Middle East Headquarters 875 Dearborn Drive AMETEK Singapore Office AMETEK Solidstate Controls Columbus, Ohio 43085 43 Changi South Ave. 2 #04-01 P.O. Box: 17067 Phone: +1-614-846-7500 Singapore 486164 Jebel Ali F.Z.; Dubai, U.A.E. Toll Free: +1-800-635-7300 Phone: +65-6484-2388 Phone: +971-50-5584054 Fax: +1-614-885-3990 Fax: +65-6481-6588 Alt Phone: +971-50-5720648 Mexico Headquarters Brazil Headquarters India Headquarters Avenida Ejercito Nacional AMETEK do Brasil Ltda AMETEK Instruments India Pvt. Ltd. Number 423 2o. Colonia Granada Rod. Eng° Ermênio de Oliveira Penteado Office No. C1, Rachana House C.P. 11520 Miguel Hidalgo, Mexico, D.F. (SP75) - Km 57, Barrio Tombadouro CTS No. 1229/BFP No. 615/B Phone: +52-55-5250-1132 Indaiatuba - SP - Brasil, 13337-300 Next to Sagar Arcade, F.C. Road, Fax: +52-55-5250-7981 Phone: +55-16-2107-4100 Pune-411 004, Maharashtra, India Phone: +91-77-3839-1890 VISIT OUR WEBSITES: English: www.solidstatecontrolsinc.com Nuclear: www.nuclearups.com Spanish: www.solidstatecontrolsinc-esp.com Russian: www.solidstatecontrolsinc-ru.com Chinese: www.solidstatecontrolsinc-chn.com Brazilian Portuguese: www.solidstatecontrolsinc-bz.com

[close]

p. 6

T H E PURPO SE OF OUR BUSINESS IS T O PROVI D E CONT I NU I T Y OF E L E CT RI CA L P O W ER TO KEEP BU SI N E SSE S I N BU SI N E SS. All Facilities are ISO 9001 Certified World Headquarters Asia Pacific Headquarters Middle East Headquarters 875 Dearborn Drive AMETEK Singapore Office AMETEK Solidstate Controls Columbus, Ohio 43085 43 Changi South Ave. 2 #04-01 P.O. Box: 17067 Phone: +1-614-846-7500 Singapore 486164 Jebel Ali F.Z.; Dubai, U.A.E. Toll Free: +1-800-635-7300 Phone: +65-6484-2388 Phone: +971-50-5584054 Fax: +1-614-885-3990 Fax: +65-6481-6588 Alt Phone: +971-50-5720648 Mexico Headquarters Brazil Headquarters India Headquarters Avenida Ejercito Nacional AMETEK do Brasil Ltda AMETEK Instruments India Pvt. Ltd. Number 423 2o. Colonia Granada Rod. Eng° Ermênio de Oliveira Penteado Office No. C1, Rachana House C.P. 11520 Miguel Hidalgo, Mexico, D.F. (SP75) - Km 57, Barrio Tombadouro CTS No. 1229/BFP No. 615/B Phone: +52-55-5250-1132 Indaiatuba - SP - Brasil, 13337-300 Next to Sagar Arcade, F.C. Road, Fax: +52-55-5250-7981 Phone: +55-16-2107-4100 Pune-411 004, Maharashtra, India Phone: +91-77-3839-1890 VISIT OUR WEBSITES: English: www.solidstatecontrolsinc.com Nuclear: www.nuclearups.com Spanish: www.solidstatecontrolsinc-esp.com Russian: www.solidstatecontrolsinc-ru.com Chinese: www.solidstatecontrolsinc-chn.com Brazilian Portuguese: www.solidstatecontrolsinc-bz.com